Sponsored Content
Full Discussion: Newbie UPS help
Top Forums UNIX for Dummies Questions & Answers Newbie UPS help Post 5768 by jeremiebarber on Wednesday 22nd of August 2001 11:44:16 AM
Old 08-22-2001
Question Newbie UPS help

I am a newbie and I just got a Sun Ultra 5, and want an UPS. I have been looking at the different models, but I do not know which brand has software that is compatable with Solaris 2.8 for automatic shutdown. I have looked at the power setup options in Solaris, but there doesn't seem to be any options for auto shutdown. If anyone can help get me started, it would be much appreciated. ThanksSmilie
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

UPS for HP-9000

Hello Everyone I run 4 HP 9000 servers with HP-UX 11.0 on all 4, with an Infomix Database. About 6 months ago one system starting acting real weird it will display the message that it lost power (which did not) and it would shutdown, Then roughly 30 seconds later it would then say power has... (4 Replies)
Discussion started by: JackieRyan26
4 Replies

2. Solaris

Suns and UPS tripplite

I'm having some trouble getting my ups to work on my Sun ultra enterprise servers. I have it hooked to serial port b and i have the tripplite power alert software installed and running, but it doesn't see the connection, is there something else i'm supposed to do to make it realize it is hooked to... (2 Replies)
Discussion started by: kymberm
2 Replies

3. Solaris

installing a UPS on a sun workstation

Has anyone ever setup the APC powerchute (business edition agent) software, using a USB drive on any solaris machines? We installed the software, and it doesnt seem to be giving the option for a /dev/usb device, it only gives options of /ttya, ttyb etc... anyone ever done this with a USB? or... (0 Replies)
Discussion started by: BG_JrAdmin
0 Replies

4. Solaris

UPS Installation

Dear All, I have installed package ups reillo in solaris but i could not use setup normaly, i could not connection with ttya , i need connect with ups for set system shutdown and another configuration. please i need help for solution thanks. (0 Replies)
Discussion started by: athurbayunata
0 Replies

5. What is on Your Mind?

any goof ups like this?

This thread reminded me of a couple of screwups made by an operator in my old job. The ops used to run OS backups through a script which asked for the path to the tape (/dev/rmt/whatnot). We (the sysadmins) would give these to the ops if a new server was added or the h/w path changed. One Sunday... (4 Replies)
Discussion started by: blowtorch
4 Replies

6. HP-UX

UPS options other than Powertrust for D380

We have a D380 server running 10.20 for disaster recovery in the event we ever needed it. Hardly robust, dual processor, 4 4.3gb HDD, DDS3 tape drive, CD-ROM and external DLT4000 tape drive. Are there any 3rd-party UPS options that anyone could recommend that would provide for graceful shutdown? ... (3 Replies)
Discussion started by: mtedeschi
3 Replies

7. Shell Programming and Scripting

script to poweroff when running on UPS

Hi all, The place where i stay experiences lot of power cuts and my solaris box is almost always on. It so happens that many times i will not be around to switch it off as soon as there is a power cut..(i also have UPS which provides alternative supply for 15min) So i wanted to write a script... (3 Replies)
Discussion started by: wrapster
3 Replies

8. UNIX for Dummies Questions & Answers

telnet via ssh to an APC UPS

Hello! First post, please be gentle! I have some APC UPS devices that I'm trying to log in to. They are currently configured to use telnet -- as a safety precaution, they can only be accessed from our 'bounce' machine. Because I want to do this from a script on my local machine, I'm doing it... (2 Replies)
Discussion started by: Korla Plankton
2 Replies

9. Hardware

CyberPower UPS

Is anyone here using this brand, and if so, how satisfied are you with its 'PowerPanel for Linux' software? Any problems? (0 Replies)
Discussion started by: Varsel
0 Replies

10. What is on Your Mind?

The green pop-ups...

Admins... I just lerve the pop-ups that appear whilst replying to someones post. It reminds me of "Paperclip" from my MS Windows days... ;oDD Love it, as it makes me smile, telling me I am creating a thread ATM... ;o) Neat little addition/feature guys... (4 Replies)
Discussion started by: wisecracker
4 Replies
CLONE(8)							    NUT Manual								  CLONE(8)

NAME
clone - UPS driver clone NOTE
This man page only documents the specific features of the clone driver. For information about the core driver, see nutupsdrv(8). DESCRIPTION
This driver, which sits on top of another driver socket, allows users to group clients to a particular outlet of a device and deal with this output as if it was a normal UPS. EXTRA ARGUMENTS
This driver supports the following settings: load.off=command Recommended. Set the command on the "real" UPS driver that will be used to switch off the outlet. You need both load.off and load.on in order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT). load.on=command Recommended. Set the command on the "real" UPS driver that will be used to switch on the outlet. You need both load.off and load.on in order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT). load.status=value Recommended. Set the variable on the "real" UPS driver that will be used to indicate the outlet status (i.e. on/off). If not specified, the clone driver will attempt to keep track of the outlet status, but this is less reliable. offdelay=num Set the timer (in seconds) before the outlet is turned off after the shutdown condition (OB LB) for this outlet is met or a command to shutdown was issued. Defaults to 120 seconds. ondelay=num Set the timer (in seconds) for the outlet to switch on in case the power returns after the oulet has been switched off. Defaults to 30 seconds. mincharge=value Set the remaining battery level when the clone UPS switches to LB (percent). minruntime=value Set the remaining battery runtime when the clone UPS switches to LB (seconds). IMPLEMENTATION
The port specification in the ups.conf(5) reference the driver socket that the "real" UPS driver is using. For example: [realups] driver = usbhid-ups port = auto [clone-outlet-1] driver = clone port = usbhid-ups-realups load.on = outlet.1.load.on load.off = outlet.1.load.off load.status = outlet.1.status [...] IMPORTANT
Unlike a real UPS, you should not configure a upsmon master for this driver. When a upsmon master sees the OB LB flags and tells the upsd server it is OK to initiate the shutdown sequence, the server will latch the FSD status and it will not be possible to restart the systems connected without restarting the upsd server. This will be a problem if the power returns after the clone UPS initiated the shutdown sequence on it's outlet, but returns before the real UPS begins shutting down. The solution is in the clone driver, that will insert the FSD flag if needed without the help of a upsmon master. CAVEATS
The clone UPS will follow the status on the real UPS driver. You can only make the clone UPS shutdown earlier than the real UPS driver, not later. If the real UPS driver initiates a shutdown, the clone UPS driver will immediately follow. Be aware that the commands to shutdown/restart an outlet on the real UPS drivers are not affected, so if you tell the real UPS driver to shutdown the outlet of the clone UPS driver, your clients will lose power without warning. AUTHOR
Arjen de Korte <adkorte-guest@alioth.debian.org> SEE ALSO
upscmd(1), upsrw(1), ups.conf(5), nutupsdrv(8) Internet Resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 CLONE(8)
All times are GMT -4. The time now is 02:44 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy