Hi,
please check with "lsvg -l <vgname>" command if your rd and db logical volumes exist.
Following commands could be used to find out how logical volume is mirrored:
# lsvg
rootvg
# lsvg -l rootvg
rootvg:
LV NAME TYPE LPs PPs PVs LV STATE MOUNT POINT
hd5 boot 1 2 2 closed/syncd N/A
hd6 paging 48 96 2 open/syncd N/A
hd61 paging 48 96 2 open/syncd N/A
hd8 jfslog 1 2 2 open/syncd N/A
hd4 jfs 5 10 2 open/syncd /
hd2 jfs 173 346 2 open/syncd /usr
hd9var jfs 86 172 2 open/syncd /var
hd3 jfs 40 80 2 open/syncd /tmp
hd1 jfs 8 16 2 open/syncd /home
hd10opt jfs 3 3 1 open/syncd /opt
# lslv -l hd5
hd5:N/A
PV COPIES IN BAND DISTRIBUTION
hdisk0 001:000:000 100% 001:000:000:000:000
hdisk6 001:000:000 100% 001:000:000:000:000
# lslv -m hd5
hd5:N/A
LP PP1 PV1 PP2 PV2 PP3 PV3
0001 0001 hdisk0 0001 hdisk6
--Tommy
10 More Discussions You Might Find Interesting
1. AIX
Hello
I have a question
On one of my aix servers if I type lsvg -l rootvg I got this
0516-1147 : Warning - logical volume waslv may be partially mirrored.
waslv jfs2 277 477 3 open/syncd /usr/WebSphere
If I type lslv -m waslv |more
waslv:/usr/WebSphere... (4 Replies)
Discussion started by: lo-lp-kl
4 Replies
2. Solaris
Hi guys,
I havent done this before but iam trying to create an image of a mirrorred drive.
Correct me if iam wrong, but when i have two disks setup in raid configuration and have them mirrored in solaris. It then defines at one entity.
How would i create a "flar" image of that one entity... (3 Replies)
Discussion started by: tlee
3 Replies
3. Shell Programming and Scripting
Hi can someone please help me on this.
I need to perform this code:
Grep any lines that meets the following criteria
(A AND B) OR (A AND C)
I tried this code, but it didn't work
Grep-I "A &&B" | "A&&C" *.* $
thanks in advance (12 Replies)
Discussion started by: Needhelp2
12 Replies
4. Solaris
We use SW mirroring (RAID1) using SVM for our SUN servers (which we OEM to end clients with our application on). When I need to make a tape backup for the server (disk), I disable mirroring and perform backup of the entire disk to tape using ufsdump. This process requires an outage and sensitive as... (8 Replies)
Discussion started by: StarSol
8 Replies
5. UNIX for Advanced & Expert Users
I have a HP proliant ML 570 G3 with two 146GB disk drives mirrored(RAID1+0)
windows server 2003 was installed on that disk.
I will add a disk.(scsi 300GB)
I will install Linux on that additional disk.
I want to create multiple-boot system.
Is it possible?
I wanna know how to create... (0 Replies)
Discussion started by: lifegeek
0 Replies
6. HP-UX
hi every body
i want to know which command tell me more detailes to know the 2 disks mirrored or not ? in group like vg00 (5 Replies)
Discussion started by: maxim42
5 Replies
7. HP-UX
Hello All,
Am trynig to identify if the local HD's on our BL860 (running 11v3) are indeed mirrored to each other.
Cheers,
Cameron (3 Replies)
Discussion started by: Cameron
3 Replies
8. Solaris
# metastat
d1: Mirror
Submirror 0: d11
State: Okay
Submirror 1: d12
State: Okay
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 14582208 blocks (7.0 GB)
d11: Submirror of d1
State: Okay
Size: 14582208 blocks... (2 Replies)
Discussion started by: Exposure
2 Replies
9. AIX
Hi all,
I need to extend a lv, but unfortunately I do not have enough space on my mirrored Volume group.
I've planned to add 2 more disks to this vg (for mirroring)
But ... what's the next steps to extend my lv using these 2 disks with a valid mirroring ?
1. extendvg myvg disk1 disk2... (3 Replies)
Discussion started by: unclefab
3 Replies
10. HP-UX
Want to extend the /home filesystem:
Filesystem kbytes used avail %used Mounted on
/dev/vg00/lvol4 262144 260088 2056 99% /home
root@server:./root # vgdisplay vg00
--- Volume groups ---
VG Name /dev/vg00
VG Write Access read/write
VG Status available
Max LV 255
Cur LV 11
Open... (4 Replies)
Discussion started by: proactiveaditya
4 Replies
CCD(4) BSD Kernel Interfaces Manual CCD(4)
NAME
ccd -- Concatenated disk driver
SYNOPSIS
pseudo-device ccd [count]
DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk.
This document assumes that you're familiar with how to generate kernels, how to properly configure disks and pseudo-devices in a kernel con-
figuration file, and how to partition disks.
Note that the 'raw' partitions of the disks must not be combined. Each component partition should be offset at least one cylinder from the
beginning of the component disk. This avoids potential conflicts between the component disk's disklabel and the ccd's disklabel. The kernel
will only allow component partitions of type FS_CCD. But for now, it allows partition of all types since some port lacks support of an on-
disk BSD disklabel. The partition of FS_UNUSED may be rejected because device driver of component disk will refuse it.
In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file:
pseudo-device ccd 4 # concatenated disk devices
The count argument is how many ccds memory is allocated for at boot time. In this example, no more than 4 ccds may be configured.
A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0.
If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase performance. Since the interleave factor is
expressed in units of DEV_BSIZE, one must account for sector sizes other than DEV_BSIZE in order to calculate the correct interleave. The
kernel will not allow an interleave factor less than the size of the largest component sector divided by DEV_BSIZE.
Note that best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different
disk types.
Also note that the total size of concatenated disk may vary depending on the interleave factor even if the exact same components are concate-
nated. And an old on-disk disklabel may be read after interleave factor change. As a result, the disklabel may contain wrong partition
geometry and will cause an error when doing I/O near the end of concatenated disk.
There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information.
WARNINGS
If just one (or more) of the disks in a non-mirrored ccd fails, the entire file system will be lost.
FILES
/dev/{,r}ccd* ccd device special files.
SEE ALSO
config(1), MAKEDEV(8), ccdconfig(8), fsck(8), mount(8), newfs(8)
HISTORY
The concatenated disk driver was originally written at the University of Utah.
BSD
March 5, 2004 BSD