Sponsored Content
Full Discussion: Dell Poweredge 2400 / 533
UNIX Standards and Benchmarks UNIX & LINUX Benchmarks (Version 3.11) Linux Benchmarks Dell Poweredge 2400 / 533 Post 51833 by happy*nix on Wednesday 2nd of June 2004 11:31:40 PM
Old 06-03-2004
Gentoo 2004.1 AMD64

RIG: Nvidia Gforce3 250
AMD Athlon64 2800 (412MHz FSB)
2GB PC3200 RAM (2, 1GB DIMMS)
Hitachi 160GB SATA Drives
3ware escalade RAID controller Raid5
GENTOO 2004.1 stage2 install 64bit

CHOST="x86_64-pc-linux-gnu"
CFLAGS="-DTIME -msse -msse2 -m3dnow -m64 -O2"

Results:
Quote:
BYTE UNIX Benchmarks (Version 3.11)
System -- Linux VES-bear 2.6.5-gentoo-r1 #2 Sat May 22 21:23:30 Local time zone must be set--see zic manu x86_64 4 GNU/Linux
Start Benchmark Run: Mon May 31 21:52:23 CDT 2004
13 interactive users.
Dhrystone 2 without register variables 5398108.6 lps (10 secs, 6 samples)
Dhrystone 2 using register variables 5360057.0 lps (10 secs, 6 samples)
Arithmetic Test (type = arithoh) 8559222.0 lps (10 secs, 6 samples)
Arithmetic Test (type = register) 384388.5 lps (10 secs, 6 samples)
Arithmetic Test (type = short) 376582.4 lps (10 secs, 6 samples)
Arithmetic Test (type = int) 384470.8 lps (10 secs, 6 samples)
Arithmetic Test (type = long) 224603.1 lps (10 secs, 6 samples)
Arithmetic Test (type = float) 976770.2 lps (10 secs, 6 samples)
Arithmetic Test (type = double) 881900.2 lps (10 secs, 6 samples)
System Call Overhead Test 1833903.8 lps (10 secs, 6 samples)
Pipe Throughput Test 1192333.6 lps (10 secs, 6 samples)
Pipe-based Context Switching Test no measured results
Process Creation Test 11411.8 lps (10 secs, 6 samples)
Execl Throughput Test no measured results
File Read (10 seconds) 4920490.0 KBps (10 secs, 6 samples)
File Write (10 seconds) 613887.0 KBps (10 secs, 6 samples)
File Copy (10 seconds) 101231.0 KBps (10 secs, 6 samples)
File Read (30 seconds) 4949798.0 KBps (30 secs, 6 samples)
File Write (30 seconds) 632218.0 KBps (30 secs, 6 samples)
File Copy (30 seconds) 45708.0 KBps (30 secs, 6 samples)
C Compiler Test 1193.7 lpm (60 secs, 3 samples)
Shell scripts (1 concurrent) 5188.3 lpm (60 secs, 3 samples)
Shell scripts (2 concurrent) 2735.7 lpm (60 secs, 3 samples)
Shell scripts (4 concurrent) 1405.3 lpm (60 secs, 3 samples)
Shell scripts (8 concurrent) 709.3 lpm (60 secs, 3 samples)
Dc: sqrt(2) to 99 decimal places 160117.5 lpm (60 secs, 6 samples)
Recursion Test--Tower of Hanoi 90029.9 lps (10 secs, 6 samples)


INDEX VALUES
TEST BASELINE RESULT INDEX

Arithmetic Test (type = double) 2541.7 881900.2 347.0
Dhrystone 2 without register variables 22366.3 5398108.6 241.4
Execl Throughput Test 16.5 0.0 0.0
File Copy (30 seconds) 179.0 45708.0 255.4
Pipe-based Context Switching Test 1318.5 0.0 0.0
Shell scripts (8 concurrent) 4.0 709.3 177.3
=========
SUM of 6 items 1021.0
AVERAGE 170.2
 

8 More Discussions You Might Find Interesting

1. Linux Benchmarks

Dell Dual Xeon PowerEdge 4600

Notes: System Configuration: Dell Computer Corporation PowerEdge 4600 (4 X Intel(R) XEON(TM) CPU 2.00GHz 1988.782 MHz) hyperthreaded System clock frequency: 99.0827 MHz Memory size (approximate): 2559 Megabytes ========================= CPUs ======================== CPU # CPU... (0 Replies)
Discussion started by: tnorth
0 Replies

2. Solaris

Installing Solaris 10 on Dell PowerEdge 2800

hi, i am trying to install solaris 10 (on 4 cd's downloaded from the sun website) on my dell poweredge 2800 server. 2 xeon processors, 2GB of RAM and 2 NICS, 73 GB SCSI (maxtor ultra320, 3.5 series), i can give more details on request... the installation crashes when trying to detect the NICS... (0 Replies)
Discussion started by: xinugeek
0 Replies

3. Red Hat

Installing RedHat 8.0 onto Dell PowerEdge SC1425 - hdc: status error: status = 0x58

I have successfully installed RedHat 8.0 onto a Dell PowerEdge SC1425 today. This server has two SATA hard drives, and an IDE DVD-ROM drive. Using the following kernel parameters, i successfully installed across both hard drives from CD: ide0=0x1f0,0x3f6,14 vga=791 resolution=1024x768 expert... (5 Replies)
Discussion started by: fishsponge
5 Replies

4. Filesystems, Disks and Memory

Linux and Dell 1500sc Poweredge Server

Does anybody no how to get around the fact that the Red Hat installation does not see the SCSI hard drives. It lets you manually pick the proper device, but still fails saying no drive detected (or something to that effect). I was going to install windows 2003 Server and use VMware...but again,... (1 Reply)
Discussion started by: Fatflea
1 Replies

5. UNIX for Dummies Questions & Answers

Stange problem Dell PowerEdge 1950/ Boradcom Netextreme NIC

I have 2 Dell Poweredge 1950 servers running . I have been having intermittent performance issues with the NIC cards on one of them. The two servers are identical and are running the same operating system. The server that has the issue is on the DMZ on a a static IP and is hosting a website. ... (0 Replies)
Discussion started by: skotapal
0 Replies

6. SCO

Continueing relyability problems with SCO 6.0 on Dell Poweredge 1800 with PERC DC4.

Hello all, I'am experiencing weird relyability problems with a SCO 6.0 Openserver server that runs on a Dell Poweredge 1800 equipped with a PERC DC4 raid controller and 4 36 GB 15 K rpm hot swappable scsi harddisks. It runs a RAID 10 configuration. It uses the mega hba, Revision 8.03a Release... (1 Reply)
Discussion started by: frederik1
1 Replies

7. Programming

/dev/mem on Dell Poweredge

Hi, I have a C++ program to access /dev/mem and retrieve details like Vendor, Manufacturer details of the motherboard. This works fine on all the machines except for on Dell Poweredge 2850,1950... machines. I receive a 'EFAULT' when I try to access /dev/mem on these servers. I suspect some... (1 Reply)
Discussion started by: ragisreekanth
1 Replies

8. SCO

Dell PowerEdge 2600 tape backup

I was asked to get a Dell PowerEdge 2600 server, out of warranty, running SCO 3.2v5.06 to perform a full backup. I spent hours researching and preparing a strategy only to fail on-site. The only device names in /dev for a tape drive were /dev/xStp0 /dev/xcdt0 /dev/xct0 ... (6 Replies)
Discussion started by: ezlarry
6 Replies
volcheck(1)							   User Commands						       volcheck(1)

NAME
volcheck - checks for media in a drive and by default checks all floppy media SYNOPSIS
volcheck [-v] [-i secs] [-t secs] pathname DESCRIPTION
The volcheck utility tells Volume Management to look at each dev/pathname in sequence and determine if new media has been inserted in the drive. The default action is to volcheck all checkable media managed by volume management. OPTIONS
The following options are supported: -i secs Set the frequency of device checking to secs seconds. The default is 2 seconds. The minimum frequency is 1 second. -t secs Check the named device(s) for the next secs seconds. The maximum number of seconds allowed is 28800, which is 8 hours. The fre- quency of checking is specified by -i. There is no default total time. -v Verbose. OPERANDS
The following operands are supported: pathname The path name of a media device. EXAMPLES
Example 1: A sample of the volcheck command. The following example example% volcheck -v /dev/diskette /dev/diskette has media asks Volume Management to examine the floppy drive for new media. The following example example% volcheck -i 2 -t 600 /dev/diskette1 & asks Volume Management if there is a floppy in the floppy drive every 2 seconds for 600 seconds (10 minutes). FILES
/dev/volctl Volume Management control port ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWvolu | +-----------------------------+-----------------------------+ SEE ALSO
eject(1), volcancel(1), volmissing(1) rmmount(1M), vold(1M), rmmount.conf(4), vold.conf(4), attributes(5), volfs(7FS) WARNINGS
Due to a hardware limitation in many floppy drives, the act of checking for media causes mechanical action in the floppy drive. Continu- ous polling of the floppy drive will cause the drive to wear out. It is recommended that polling the drive only be performed during periods of high use. SunOS 5.10 21 Feb 1997 volcheck(1)
All times are GMT -4. The time now is 05:39 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy