Sponsored Content
Special Forums IP Networking Quick Poll: Solaris IP Multipathing Post 44400 by RTM on Friday 5th of December 2003 11:16:28 AM
Old 12-05-2003
Quote:
Whenever a single point of failure can be removed, it should be.
If it is cost effective. In the case of interface cards it is but then add in the cost of using two ports for each network your one system is on...more switches are needed, folks complain about running out of IP addresses...some battles are not worth it. If you had a SUN E10K, you would have to buy a second because of the single point of failure that is internal to it. Quite costly.
 

7 More Discussions You Might Find Interesting

1. Solaris

Quick question about Solaris =)

:D Just curious, I know that solaris 2.0-2.x_present are System V UNIX... But, I have only used Solaris 10, 9 and 2.5... On a 2.5 Sparc box, after you login you get presented with the usual SunOS 5.5.1 then UNIX(R) System V Release 4.0 I know Solaris 9 and 10 do not include this banner... ... (0 Replies)
Discussion started by: ssorel
0 Replies

2. Solaris

solaris multipathing

I have solaris 10 sparc. I installed a Qlogic hba card. This card is connected on a brocade switch and the brocade is connected on 2 different controllers on a Hitachi disk bay. I formated 2 luns. On my solaris system, i have 4 disk. How to configure solaris 10 to fix the dual disk view. ... (4 Replies)
Discussion started by: simquest
4 Replies

3. Solaris

Solaris IP Multipathing (IPMP) Help

Hello All, I work for a Health care company at a local trauma hospital. I maintain a Picture Archiving and Communication System (PAC's). Basically, any medical images (X-Ray, CT, MRI, Mammo, etc) are stored digitally on the servers for viewing and dictation from diagnostic stations. I took over... (10 Replies)
Discussion started by: mainegeek
10 Replies

4. Solaris

Solaris IP Multipathing

Hi, I saw your post on the forums about how to setup IP multipathing. I wanted your help on the below situation . I have 2 servers A and B . Now they should be connected to 2 network switches . S1 and S2. Now is it possible to have IP Multipathing on each of the servers as follows ? ... (0 Replies)
Discussion started by: maadhuu
0 Replies

5. Solaris

Disable Inbuilt multipathing software of Solaris 10

Dear UNIX Gurus I need to know how to disable MPXIO feature (Inbuilt multipathing software of Solaris 10) as we are going to implemented iSCSI EMC based SAN. I am bit new to this feature so kindly suggest how to disable it Regards (4 Replies)
Discussion started by: girish.batra
4 Replies

6. Solaris

Solaris multipathing

Hai we using emc storage which is conneted to M5000 through san switch. we asign 13 luns but in server it is showing 22 luns. i enable the solaris multipathing (MPxIO) #more /kernel/drv/fp.conf in that file MPxio-disable=no #mpathadm list lu it shows ... (2 Replies)
Discussion started by: joshmani
2 Replies

7. Solaris

ZeusIOPS multipathing failed Solaris 11

hi, just installed solaris 11.1 (11.1.9.5.1) on a sun7410 ZFSSA (x4440 + j4400), but when I enable multipathing with "stmsboot -e", only the 1TB SATA drives inside the j4400 are configured as multipathed vhci / mpxio devices, but the logzillas / ZeusIOPS drives are skipped. the server is... (0 Replies)
Discussion started by: pressy
0 Replies
PCAP_FINDALLDEVS(3PCAP) 												   PCAP_FINDALLDEVS(3PCAP)

NAME
pcap_findalldevs, pcap_freealldevs - get a list of capture devices, and free that list SYNOPSIS
#include <pcap/pcap.h> char errbuf[PCAP_ERRBUF_SIZE]; int pcap_findalldevs(pcap_if_t **alldevsp, char *errbuf); void pcap_freealldevs(pcap_if_t *alldevs); DESCRIPTION
pcap_findalldevs() constructs a list of network devices that can be opened with pcap_create() and pcap_activate() or with pcap_open_live(). (Note that there may be network devices that cannot be opened by the process calling pcap_findalldevs(), because, for example, that process does not have sufficient privileges to open them for capturing; if so, those devices will not appear on the list.) If pcap_findalldevs() succeeds, the pointer pointed to by alldevsp is set to point to the first element of the list, or to NULL if no devices were found (this is considered success). Each element of the list is of type pcap_if_t, and has the following members: next if not NULL, a pointer to the next element in the list; NULL for the last element of the list name a pointer to a string giving a name for the device to pass to pcap_open_live() description if not NULL, a pointer to a string giving a human-readable description of the device addresses a pointer to the first element of a list of network addresses for the device, or NULL if the device has no addresses flags device flags: PCAP_IF_LOOPBACK set if the device is a loopback interface PCAP_IF_UP set if the device is up PCAP_IF_RUNNING set if the device is running Each element of the list of addresses is of type pcap_addr_t, and has the following members: next if not NULL, a pointer to the next element in the list; NULL for the last element of the list addr a pointer to a struct sockaddr containing an address netmask if not NULL, a pointer to a struct sockaddr that contains the netmask corresponding to the address pointed to by addr broadaddr if not NULL, a pointer to a struct sockaddr that contains the broadcast address corresponding to the address pointed to by addr; may be null if the device doesn't support broadcasts dstaddr if not NULL, a pointer to a struct sockaddr that contains the destination address corresponding to the address pointed to by addr; may be null if the device isn't a point-to-point interface Note that the addresses in the list of addresses might be IPv4 addresses, IPv6 addresses, or some other type of addresses, so you must check the sa_family member of the struct sockaddr before interpreting the contents of the address; do not assume that the addresses are all IPv4 addresses, or even all IPv4 or IPv6 addresses. IPv4 addresses have the value AF_INET, IPv6 addresses have the value AF_INET6 (which older operating systems that don't support IPv6 might not define), and other addresses have other values. Whether other addresses are returned, and what types they might have is platform-dependent. For IPv4 addresses, the struct sockaddr pointer can be interpreted as if it pointed to a struct sockaddr_in; for IPv6 addresses, it can be interpreted as if it pointed to a struct sockaddr_in6. The list of devices must be freed with pcap_freealldevs(), which frees the list pointed to by alldevs. RETURN VALUE
pcap_findalldevs() returns 0 on success and -1 on failure; as indicated, finding no devices is considered success, rather than failure, so 0 will be returned in that case. If -1 is returned, errbuf is filled in with an appropriate error message. errbuf is assumed to be able to hold at least PCAP_ERRBUF_SIZE chars. SEE ALSO
pcap(3PCAP), pcap_create(3PCAP), pcap_activate(3PCAP), pcap_open_live(3PCAP) 7 April 2014 PCAP_FINDALLDEVS(3PCAP)