Sponsored Content
Top Forums UNIX for Dummies Questions & Answers Strange email problem, red hat/qmail Post 35098 by scg on Thursday 27th of March 2003 01:19:57 PM
Old 03-27-2003
Thanks for the help, but I've worked it out. The pcs on the second network card have internal IP addresses within a range that the mail server doesn't understand. So each time they were trying to send an email it was doing a reverse lookup on their IP, although the name server appears to have gone down and has been down since the problem started. All the other users on the other network card have public IPs which it knows about and doesn't need to look up.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Problem Downloading Red Hat

I've been having problems downloading Red Hat 7.2 from their FTP site. It downloads rather slowly(between 2-3k/sec, I'm on broadband) and after about 10 minutes stops downloading altogether. Am I doing something wrong? (2 Replies)
Discussion started by: Tradewynd
2 Replies

2. UNIX for Dummies Questions & Answers

Please Help Me With This Linux Red Hat 7.2 Modem Problem

I cant get my modem to work. Linux just isn't recognizing it. every time I typed wvdial, i get a message saying my modem is not responding I tried looking for drivers at the website Neo directed me to but I just couldn't find the right one from the information I was given about my modem... (2 Replies)
Discussion started by: TRUEST
2 Replies

3. UNIX for Dummies Questions & Answers

Linux Red Hat 7.2 Problem

how come red hat doesn't have this programs which was already supposed to be on it?? take for instance, I was reading this Linux book that says for me to do some work in glint X11 client for packagement. it says glint is accessible from the command line or control panel. the problem is, I... (4 Replies)
Discussion started by: TRUEST
4 Replies

4. UNIX Desktop Questions & Answers

Red Hat loading problem

when i try to load Redhat 7.2 the screen gets all mished together as if it were a meltdown the book says its a prob with X but it dosnt really say what to do WINMe works fine i have a radeon 64 MB card 1 gig processor and 2 HDs on a Dell 1 GHZ how do i fix this ? (1 Reply)
Discussion started by: ASpin
1 Replies

5. Linux

Red Hat RPM problem

I have my system setup different then the conventional setup: # df -h Filesystem Size Used Avail Use% Mounted on /dev/hdc2 2.0G 977M 936M 52% / /dev/hdc1 97M 9.0M 83M 10% /boot none 251M 0 251M 0% /dev/shm So when I try... (2 Replies)
Discussion started by: jasonr
2 Replies

6. Linux

Installation Problem on Red hat linux 9

Hi, I am trying to install our new acquired Red Hat linux 9 on Compaq Proliant ML370. However, l has already configured the raid 0+1. The linux installation starts from the CD, its allows for the selection of Language, keyboard but l am stocked at choosing the installation package media. I... (4 Replies)
Discussion started by: kayode
4 Replies

7. UNIX for Dummies Questions & Answers

Problem Red Hat 9 Installation

I have a problem with a red hat 9 install on a compaq laptop. I installed the OS and everything tests ok but It boots to a blank screen instead of the GUI login I wanted. What can I do to correct this instead of installing all over. I tried the rescue option several times and tried to run... (2 Replies)
Discussion started by: vedder191
2 Replies

8. Linux

Red Hat linux(Advance server) problem

we are receiving following error in our application server & server not booted:- "INIT IP ID x ,Respawning too fast; disable for 5 minutes." Please give me solution for above mention problem as early as possible . AKM (3 Replies)
Discussion started by: akm9999
3 Replies

9. Infrastructure Monitoring

Problem Installing Cacti on Red Hat

Can someone please point me in the direction of where I can find out how to install cacti? there doesn't seem to be straightforward steps for it. after downloading the tar.gz file from cacti.net, there's basically no instructions of what to do from that point on. any help will be appreciated. ... (1 Reply)
Discussion started by: SkySmart
1 Replies

10. Red Hat

Red Hat application server ssl keystore problem

A client is accessing our JBoss server. In the past, we set up a keystore and everything worked fine. That certificat expired and we've installed the new one. Now the client is getting the following error - HTTP/1.1 500 Internal Server Error Date: Mon, 14 Apr 2014 13:25:44 GMT Server:... (1 Reply)
Discussion started by: kkinney
1 Replies
pcelx(7D)																 pcelx(7D)

NAME
pcelx - 3COM EtherLink III PCMCIA Ethernet Adapter SYNOPSIS
network@<socket>:pcelx<socket> The pcelx driver supports the 3COM EtherLink III PCMCIA PC Card as a standard Ethernet type of device conforming to the DLPI interface specification. The driver supports the hot-plugging of the PC Card. The PPA (Physical Point of Attachment) is defined by the socket number the PC Card is inserted in. This means that for IP use, the PC Card should always be plugged into the same socket that the network interface was initially brought up on or else a network reconfiguration should be done to take down the old interface and bring up the new one. The 3C589, 3C589B, and 3C589C versions of the PC Card are supported on the platform. The 3C589B and 3C589C are supported on the SPARC platform. PRECONFIGURE
o For IBM ThinkPad 760E series systems and systems using the TI PCI1130 PCI-to-CardBus chip (such as the Dell Latitude XPi CD) only: Before bringing the system onto the network, put the PC Card into 8-bit mode by creating a file called /kernel/drv/pcelx.conf contain- ing force-8bit=1;. o It is not possible to boot or install the Solaris software using a 3Com EtherLink III PC Card device. o If the 3Com PC Card device is recognized, the pcelx driver is automatically loaded, ports and IRQs allocated, and special files cre- ated (if they don't already exist). No manual configuration of the hardware is necessary or possible. Known Problems and Limitations Network services are automatically started when the system is booted. These services are not started when a network interface is added or shut down after the system has been brought up. CONFIGURATION
Configuration procedures include initial installation and configuration, identifying an unrecognized card and configuring two or more cards. Initial Installation and Configuration For initial installation and configuration, do the following steps: 1. Install the Solaris software. 2. Boot the system. 3. Insert the 3Com EtherLink III PC Card device. Identifying an Unrecognized Card If you insert a 3C589 card and it is not recognized (no special files created), use the prtconf command and attempt to identify the prob- lem: 1. Become root. 2. Run the prtconf -D command to see if your 3C589 card is recognized. A recognized device will appear in the prtconf output. For example: # prtconf -D . . . pcic, instance #0 (driver name: pcic) . . . network, instance #0 (driver name: pcelx) 3. If pcelx does not appear in the prtconf output, there is a problem with the PC Card adapter configuration or with the hardware. You can determine whether the problem is with the card or the adapter by attempting to use the card on another machine or by using it on the same machine using DOS. Configuring Two or More Cards Because the 3C589 card is not supported during Solaris installation, you must update network configuration files before it can be used as a network interface: 1. Create a /etc/hostname.pcelx# file (where # is a socket number) to specify the host name to be associated with this interface. 2. Add an IP address for the new host name to the /etc/inet/hosts file. 3. Ensure that the associated network is listed in /etc/inet/netmasks. 4. Ensure that the Name Service Switch /etc/nssswitch.conf configuration file includes the network and local services you need. 5. Reboot the system. Special Files Device naming in /dev follows standard LAN device naming with the exception that the PPA (physical point of attachment) unit number is the socket where the card resides, not the instance. For the pcelx driver, /dev/pcelx0 (or PPA 0 of /dev/pcelx) is the card in socket 0, while a card in socket 1 is /dev/pcelx1 (or PPA 1 of /dev/pcelx). Hot Plugging If you remove the 3C589 card, any information you send is discarded, and no error messages are given. When you reinsert the card in the same socket, the device operates normally. The behavior is similar to temporarily disconnecting the device from the network. /kernel/drv/pcelx pcelx driver /dev/pcelx DLPI Style 2 device /dev/pcelxn DLPI Style 1 device where: n is the PCMCIA physical socket number. pcmcia(7D) 20 Oct 2000 pcelx(7D)
All times are GMT -4. The time now is 09:48 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy