Sponsored Content
Full Discussion: Storage array question
Special Forums Hardware Filesystems, Disks and Memory Storage array question Post 32422 by MizzGail on Monday 25th of November 2002 03:25:51 PM
Old 11-25-2002
Question

What type of database?
We had informix on a raid5 set and performance was very poor. we mirrored our disks and make sure they were not on the same bus.
seemed to help.
 

6 More Discussions You Might Find Interesting

1. Solaris

storage array simulator

hi i haven't much experience in solaris. I would like to know about storage. how to configure,how it is working etc....can i get any simulator for doing these work? plaese send me the link . please help me advance thanks to all (2 Replies)
Discussion started by: sijocg
2 Replies

2. Solaris

Shared Storage Array is DEGRADED

Hi, On my X4200 Galaxy cluster, when i plugged out the both cables of Controller A (connected to Node 1 and Node2) , status of registered array became "Degraded". After plugging -in the cables , i should get the status of array as "OK" but i am not getting the status OK. I am using CAM... (2 Replies)
Discussion started by: deepaksharma
2 Replies

3. Solaris

A1000 Disk storage array

I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why? What should I do in order... (1 Reply)
Discussion started by: Dulasi
1 Replies

4. HP-UX

HP Storage Array

hi I need to check status and configure HP Storage Array device. HP Storageworks P2000 Please suggest (0 Replies)
Discussion started by: anand87
0 Replies

5. Solaris

Storage Array not readable

Hi We have an array connected to the machine but when i issue format command i dont see it. But the array is up and running and there are no warning lights. Is there a way to find that array from the OK boot prompt? Please advise. Thanks (9 Replies)
Discussion started by: prash358
9 Replies

6. AIX

Migrating LUNs to new storage array

All, I have a AIX server with multiple volumes and I need to move them from a legacy storage SAN to a new SAN. We are concerned because to use mirrorvg as we would have to run on a single HBA (one on the old SAN and one on the new). Our other option is to use an appliance to do a block... (3 Replies)
Discussion started by: bkchicago
3 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated disk driver SYNOPSIS
pseudo-device ccd [count] DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you're familiar with how to generate kernels, how to properly configure disks and pseudo-devices in a kernel con- figuration file, and how to partition disks. Note that the 'raw' partitions of the disks must not be combined. Each component partition should be offset at least one cylinder from the beginning of the component disk. This avoids potential conflicts between the component disk's disklabel and the ccd's disklabel. The kernel will only allow component partitions of type FS_CCD. But for now, it allows partition of all types since some port lacks support of an on- disk BSD disklabel. The partition of FS_UNUSED may be rejected because device driver of component disk will refuse it. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: pseudo-device ccd 4 # concatenated disk devices The count argument is how many ccds memory is allocated for at boot time. In this example, no more than 4 ccds may be configured. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase performance. Since the interleave factor is expressed in units of DEV_BSIZE, one must account for sector sizes other than DEV_BSIZE in order to calculate the correct interleave. The kernel will not allow an interleave factor less than the size of the largest component sector divided by DEV_BSIZE. Note that best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. Also note that the total size of concatenated disk may vary depending on the interleave factor even if the exact same components are concate- nated. And an old on-disk disklabel may be read after interleave factor change. As a result, the disklabel may contain wrong partition geometry and will cause an error when doing I/O near the end of concatenated disk. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. WARNINGS
If just one (or more) of the disks in a non-mirrored ccd fails, the entire file system will be lost. FILES
/dev/{,r}ccd* ccd device special files. SEE ALSO
config(1), MAKEDEV(8), ccdconfig(8), fsck(8), mount(8), newfs(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD