Sponsored Content
Full Discussion: Storage array question
Special Forums Hardware Filesystems, Disks and Memory Storage array question Post 32414 by ncmurf00 on Monday 25th of November 2002 12:10:05 PM
Old 11-25-2002
Storage array question

We just purchased a MOD30 disk array strage system.
We have 15 drives and 2 hot spares.
We're running a database app with 8 data sets.
I'm trying to get the best i/o speed out of my disk configuration.
Right now I have 3 raid5 arrays setup. This seems to offer the same performance as having the datafiles on separate hard drives with Raid1.
I distributed the data files evenly across the 3 raids.
Does anyone know what would make for the optimum config for reading? We run a lot of queries that take a long time to run through the database. I'm looking for faster searches.

Any thoughts?
 

6 More Discussions You Might Find Interesting

1. Solaris

storage array simulator

hi i haven't much experience in solaris. I would like to know about storage. how to configure,how it is working etc....can i get any simulator for doing these work? plaese send me the link . please help me advance thanks to all (2 Replies)
Discussion started by: sijocg
2 Replies

2. Solaris

Shared Storage Array is DEGRADED

Hi, On my X4200 Galaxy cluster, when i plugged out the both cables of Controller A (connected to Node 1 and Node2) , status of registered array became "Degraded". After plugging -in the cables , i should get the status of array as "OK" but i am not getting the status OK. I am using CAM... (2 Replies)
Discussion started by: deepaksharma
2 Replies

3. Solaris

A1000 Disk storage array

I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why? What should I do in order... (1 Reply)
Discussion started by: Dulasi
1 Replies

4. HP-UX

HP Storage Array

hi I need to check status and configure HP Storage Array device. HP Storageworks P2000 Please suggest (0 Replies)
Discussion started by: anand87
0 Replies

5. Solaris

Storage Array not readable

Hi We have an array connected to the machine but when i issue format command i dont see it. But the array is up and running and there are no warning lights. Is there a way to find that array from the OK boot prompt? Please advise. Thanks (9 Replies)
Discussion started by: prash358
9 Replies

6. AIX

Migrating LUNs to new storage array

All, I have a AIX server with multiple volumes and I need to move them from a legacy storage SAN to a new SAN. We are concerned because to use mirrorvg as we would have to run on a single HBA (one on the old SAN and one on the new). Our other option is to use an appliance to do a block... (3 Replies)
Discussion started by: bkchicago
3 Replies
IOSTAT(1)						      General Commands Manual							 IOSTAT(1)

NAME
iostat - report I/O statistics SYNOPSIS
iostat [ drives ] [ interval [ count ] ] DESCRIPTION
Iostat iteratively reports the number of characters read and written to terminals per second, and, for each disk, the number of transfers per second, kilobytes transferred per second, and the milliseconds per average seek. It also gives the percentage of time the system has spent in user mode, in user mode running low priority (niced) processes, in system mode, and idling. To compute this information, for each disk, seeks and data transfer completions and number of words transferred are counted; for terminals collectively, the number of input and output characters are counted. Also, each sixtieth of a second, the state of each disk is examined and a tally is made if the disk is active. From these numbers and given the transfer rates of the devices it is possible to determine average seek times for each device. The optional interval argument causes iostat to report once each interval seconds. The first report is for all time since a reboot and each subsequent report is for the last interval only. The optional count argument restricts the number of reports. If more than 4 disk drives are configured in the system, iostat displays only the first 4 drives, with priority given to Massbus disk drives (i.e. if both Unibus and Massbus drives are present and the total number of drives exceeds 4, then some number of Unibus drives will not be displayed in favor of the Massbus drives). To force iostat to display specific drives, their names may be supplied on the command line. FILES
/dev/kmem /vmunix SEE ALSO
vmstat(1) 4th Berkeley Distribution April 29, 1985 IOSTAT(1)
All times are GMT -4. The time now is 09:41 PM.