It is
or better
Even better is to check for the elapsed time
The *-* matches anything with a dash; this is true if the process is more than one day old. So it will fix your emergency, but leave enough rpm processes running to remind you to do a root cause analysis plus a proper fix.
Hi everybody:
I have a problem. I have a output files which have this pattern:
number1
--space
block1a - 7rows/10columns/65elements
--space
block1b - 7rows/10columns/65elements
--space
block1c - 7rows/10columns/65elements
--space
number2
--space
block2a - 7rows/10columns/65elements... (0 Replies)
Hi, Im very new to the world of sed so I'm really not even sure if this is possible. What i need to do is read from a flat file and every time i see this line:
VAL=123,456
I need to change 456 to 457 for every occurence of this line in the file. The numbers 123 and 456 are different for... (6 Replies)
Hi All,
I am spooling the data some sql queries into a single file but wanted to know how to format the data of the file generated by spool.
#!/bin/sh
unset -f USAGE
USAGE () {
clear
echo "############################USAGE#######################\n"
echo "Incorrect number of... (2 Replies)
Hello,
I need help on how to "access" or manipulate the Linux ARP Cache in C, here is the description of the project i'm working in:
There are a lot of tools that analize ARP frames and send an e-mail to the sysadmin, that's easy. What i want to do is to inspect every ARP frame that arrives... (18 Replies)
Hi,
I am new to awk/unix and am trying to put together a script to manipulate the date column in a csv file.
I have file1.csv with the following contents:
Date,ID,Number,Amount,Volume,Size
01-Apr-2014,WERFG,998,105873.96,10873.96,1342.11
01-Apr-2014,POYFR,267,5681.44,5681.44,462.96
I... (2 Replies)
Hi, I am new to awk and unix programming and trying to manipulate a csv file.
My current csv file looks like this:
col1,col2,col3,col4,col5,col4,col5,col6,col7,col8
223,V,c,2,4,f,r,,y,z
223,V,c,3,2,f,r,,y,z
223,V,c,1,4,f,r,,y,z
223,V,c,4,3,f,r,,y,z
227,V,c,3,1,f,r,,y,z... (8 Replies)
Hello,
I am on a Mac and trying to clean up some monthly files with a very simple SED:
sed '3,10d;/<ACROSS>/,$d' input.txt > output.txt
(from the input, delete lines 3 - 10; then delete from the line containing <ACROSS> to the end of the file)
then output to output.txt
Even when I try... (2 Replies)
Discussion started by: verbatim
2 Replies
LEARN ABOUT ULTRIX
kill
kill(2) System Calls Manual kill(2)Name
kill - send signal to a process
Syntax
#include <sys/types.h>
#include <signal.h>
kill(pid, sig)
pid_t pid;
int sig;
Description
The system call sends the signal sig to a process specified by the process number pid. The sig can be a signal specified in a call or it
can be 0. If the sig is 0, error checking is performed, but a signal is not sent. This call can be used to check the validity of pid.
The sending and receiving processes must have the same effective user ID, otherwise this call is restricted to the superuser with the
exception of the signal SIGCONT. The signal SIGCONT can always be sent to a child or grandchild of the current process.
If the process number is 0, the signal is sent to all other processes in the sender's process group.
If the process number is negative but not -1, the signal is sent to all processes whose process-group-id is equal to the absolute value of
the process number.
The above two options are variants of
If the process number is -1, and the user is the superuser, the signal is broadcast for all processes except to system processes and the
process sending the signal.
Processes may send signals to themselves.
Environment
System Five
POSIX
When your program is compiled in the System V or POSIX environment, a signal is sent if either the real or effective uid of the sending
process matches the real or saved-set-uid (as described in ) of the receiving process. In addition, any process can use a pid of -1, and
the signal is sent to all processes subject to these permission checks.
In POSIX mode, the pid argument is of type pid_t.
Return Values
Upon successful completion, a value of 0 is returned. Otherwise, a value of -1 is returned, and is set to indicate the error.
Diagnostics
The system call fails under the following conditions:
[EINVAL] The sig is not a valid signal number.
[EPERM] The sending process is not the superuser, and its effective user ID does not match the effective user ID of the receiving
process.
[ESRCH] No process can be found corresponding to that specified by pid.
See Alsoexecve(2), getpgrp(2), getpid(2), killpg(2), sigvec(2), pause(3)kill(2)