Sponsored Content
Full Discussion: Show faulty shows PS1 faulty
Top Forums UNIX for Beginners Questions & Answers Show faulty shows PS1 faulty Post 303040474 by Peasant on Wednesday 30th of October 2019 03:57:35 AM
Old 10-30-2019
Perfectly normal.
When you unplug the PS, a fault is generated.

You can clear the fault, after you plugged it back in and it shows everything is ok.

Regards
Peasant.
This User Gave Thanks to Peasant For This Post:
 

10 More Discussions You Might Find Interesting

1. Solaris

Faulty PSU - but its still working !?!

Hello We have a power supply in an x4100 (x86) and it seems to be faulty but it is still working!?! (this box only has one PSU). We are getting Orange flashing warning light on the front of the box and the LED labelled “rear PSu” is solid orange ...We don't seem to have had any syslog error... (8 Replies)
Discussion started by: hcclnoodles
8 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Replacing a faulty volume

Hi All, I replace a sub-mirror of a mirrored volume by using below command: #metadetach d10(mirror) d11(striped) #metattach d10 d13(other striped) With above process I successfully replaced a faulty volume. I want to knoow if the process I followed is right. Or if not, what... (5 Replies)
Discussion started by: naw_deepak
5 Replies

4. Solaris

fmadm faulty output

Hi everyone, I wanted to ask a question about fmadm and explorer outputs. Recently found out that an error shows up in fmadm saying "mb is faulty but still in service" so we took an explorer send to Oracle Support. Error led wasn't on but we didn't want to risk the probability. They came up... (1 Reply)
Discussion started by: royalliege
1 Replies

5. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

6. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

7. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

8. Solaris

Is it possible to set a PSU as faulty on Solaris

Hi, I'm trying to generate an alert related to Power Supply Failure. As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty" Any ideas are welcome and highly appreciated -Thanks (3 Replies)
Discussion started by: justsam
3 Replies

9. Red Hat

HBA card faulty

Hi, How to determine if HBA card in getting faulty from linux host ? any pointers. (2 Replies)
Discussion started by: saurabh84g
2 Replies

10. Hardware

Faulty parts in a frame

Hello, Following parts need to be replaced in a frame as suggested by IBM 1. Flexible Cable 2. Service Processor Card Would these faulty parts impact all lpars which are there in this frame? Best regards, Vishal (5 Replies)
Discussion started by: admin_db
5 Replies
fmd(1M)                                                   System Administration Commands                                                   fmd(1M)

NAME
fmd - fault manager daemon SYNOPSIS
/usr/lib/fm/fmd/fmd [-V] [-f file] [-o opt=val] [-R dir] DESCRIPTION
fmd is a daemon that runs in the background on each Solaris system. fmd receives telemetry information relating to problems detected by the system software, diagnoses these problems, and initiates proactive self-healing activities such as disabling faulty components. When appropriate, the fault manager also sends a message to the syslogd(1M) service to notify an administrator that a problem has been detected. The message directs administrators to a knowledge article on Sun's web site, http://www.sun.com/msg/, which explains more about the problem impact and appropriate responses. Each problem diagnosed by the fault manager is assigned a Universal Unique Identifier (UUID). The UUID uniquely identifes this particular problem across any set of systems. The fmdump(1M) utility can be used to view the list of problems diagnosed by the fault manager, along with their UUIDs and knowledge article message identifiers. The fmadm(1M) utility can be used to view the resources on the system believed to be faulty. The fmstat(1M) utility can be used to report statistics kept by the fault manager. The fault manager is started automatically when Solaris boots, so it is not necessary to use the fmd command directly. Sun's web site explains more about what capabilities are cur- rently available for the fault manager on Solaris. OPTIONS
The following options are supported -f file Read the specified configuration file prior to searching for any of the default fault manager configuration files. -o opt=value Set the specified fault manager option to the specified value. Fault manager options are currently a Private inter- face; see attributes(5) for information about Private interfaces. -R dir Use the specified root directory for all pathnames evaluated by the fault manager, instead of the default root (/). -V Print the fault manager's version to stdout and exit. EXIT STATUS
The following exit values are returned: 0 Successful completion 1 An error occurred which prevented the fault manager from initializing, such as failure to open the telemetry trans- port. 2 Invalid command-line options were specified. FILES
/etc/fm/fmd Fault manager configuration directory /usr/lib/fm/fmd Fault manager library directory /var/fm/fmd Fault manager log directory ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWfmd | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
svcs(1), fmadm(1M), fmdump(1M), fmstat(1M), syslogd(1M), attributes(5), smf(5) http://www.sun.com/msg/ NOTES
The Fault Manager is managed by the service management facility, smf(5), under the service identifier: svc:/system/fmd:default The service's status can be queried using the svcs(1) command. Administrators should not disable the Fault Manager service. SunOS 5.10 17 Nov 2004 fmd(1M)
All times are GMT -4. The time now is 12:46 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy