Sponsored Content
Full Discussion: Show faulty shows PS1 faulty
Top Forums UNIX for Beginners Questions & Answers Show faulty shows PS1 faulty Post 303040474 by Peasant on Wednesday 30th of October 2019 03:57:35 AM
Old 10-30-2019
Perfectly normal.
When you unplug the PS, a fault is generated.

You can clear the fault, after you plugged it back in and it shows everything is ok.

Regards
Peasant.
This User Gave Thanks to Peasant For This Post:
 

10 More Discussions You Might Find Interesting

1. Solaris

Faulty PSU - but its still working !?!

Hello We have a power supply in an x4100 (x86) and it seems to be faulty but it is still working!?! (this box only has one PSU). We are getting Orange flashing warning light on the front of the box and the LED labelled “rear PSu” is solid orange ...We don't seem to have had any syslog error... (8 Replies)
Discussion started by: hcclnoodles
8 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Replacing a faulty volume

Hi All, I replace a sub-mirror of a mirrored volume by using below command: #metadetach d10(mirror) d11(striped) #metattach d10 d13(other striped) With above process I successfully replaced a faulty volume. I want to knoow if the process I followed is right. Or if not, what... (5 Replies)
Discussion started by: naw_deepak
5 Replies

4. Solaris

fmadm faulty output

Hi everyone, I wanted to ask a question about fmadm and explorer outputs. Recently found out that an error shows up in fmadm saying "mb is faulty but still in service" so we took an explorer send to Oracle Support. Error led wasn't on but we didn't want to risk the probability. They came up... (1 Reply)
Discussion started by: royalliege
1 Replies

5. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

6. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

7. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

8. Solaris

Is it possible to set a PSU as faulty on Solaris

Hi, I'm trying to generate an alert related to Power Supply Failure. As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty" Any ideas are welcome and highly appreciated -Thanks (3 Replies)
Discussion started by: justsam
3 Replies

9. Red Hat

HBA card faulty

Hi, How to determine if HBA card in getting faulty from linux host ? any pointers. (2 Replies)
Discussion started by: saurabh84g
2 Replies

10. Hardware

Faulty parts in a frame

Hello, Following parts need to be replaced in a frame as suggested by IBM 1. Flexible Cable 2. Service Processor Card Would these faulty parts impact all lpars which are there in this frame? Best regards, Vishal (5 Replies)
Discussion started by: admin_db
5 Replies
KUMOCTL(1)						      General Commands Manual							KUMOCTL(1)

NAME
kumoctl - show kumofs status SYNOPSIS
kumoctl address[:port=19750] command [options] DESCRIPTION
Show status of kumo-manager and send control commands to kumo-manager. COMMANDS
status show status of the cluster attach attach all new servers and start replace attach-noreplace attach all new servers detach detach all fault servers and start replace detach-noreplace detach all fault servers replace start replace without attach/detach full-replace start full-replace (repair consistency) backup [suffix=20090304] create backup with specified suffix enable-auto-replace enable auto replace disable-auto-replace disable auto replace STATUS
hash space timestamp The time that the list of attached kumo-servers is updated. It is updated when new kumo-server is added or existing kumo-server is down. attached node The list of attached kumo-servers. (active) is normal node and (fault) is fault node or recoverd but not re-attached node. not attached node The list of recognized but not-attached nodes. AUTO REPLACING
By default, you have to attach new kumo-servers manually using kumoctl command. If the auto replacing is enabled, new kumo-servers are attached automatically. This is experimental feature. EXAMPLE
$ kumoctl mgr1 status $ kumoctl mgr1 attach SEE ALSO
kumo-manager(1). kumoctl July 2009 KUMOCTL(1)
All times are GMT -4. The time now is 05:33 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy