10-22-2019
Hi,
Not a problem, you should try to get a note of the config prior to changing a battery - it can save a bit of greif especially if there are RAID disks involved.
Regards
Gull04
10 More Discussions You Might Find Interesting
1. Solaris
am wonder wich sun computer is better, a sun ultra or sun sparkstation, and what is the difference (7 Replies)
Discussion started by: nobody
7 Replies
2. Solaris
Hi Guys,
I have a 2nd hand Sun ultra-5, I wanted to know how to be able to run it as a normal window. I do not have any experience whatsoever with solaris/unix. Does anyone can give me a clue where to start. When I switch it goes to:
unix console login:
pa$$word:
#UNIX sendmail : enable to... (0 Replies)
Discussion started by: lingosa
0 Replies
3. Solaris
Hello,
I just bought a nice ultra 60 with 2x36gb scsi disks (fujitsu MAJ3364MC, sun partnr 540-4521).
If i do a probe-scsi-all in obp the disk anounces itself as SUN36G.
In a booted system however, I can only use 9 gb and the disk is seen in format as 9.0 gb.
My own wild uneducated... (4 Replies)
Discussion started by: poltergeist
4 Replies
4. Solaris
I just was given an Ultra 60 that I'm trying to get started so that I can re-load the system with Solaris 10. I can't seem to get the system to boot past the initial memory check. I've tried to do an Stop-A to get to the eeprom, but can't do that. My next step is to try to send a break from the... (0 Replies)
Discussion started by: zosojohnny
0 Replies
5. Solaris
Hi All,
Any idea why i'm having this warning during boot:
WARNING: /pci@1f,0/pci@1,1/ide@3/dad@1,0 (dad1):
corrupt label - wrong magic number
This happens after I added another ide HD and reinstall it from solaris 10 to solaris 8.
Thanks in advance. (7 Replies)
Discussion started by: itik
7 Replies
6. Solaris
Hi all.
I am seeing in one of our less-used servers that it crashed and now won't restart. I get the message 'continue with normal startup or boot into maintenance mode'.
I go into maintenance and run fsck on /usr0 (mentioned in error at restart) it then reboots but goes right back to... (3 Replies)
Discussion started by: jamie_collins
3 Replies
7. UNIX for Dummies Questions & Answers
Folks;
My SUN Ultra 10 5.9 won't boot. It only stops after counting the memory on the white screen then hangs there with nothing. even the power button won't take it down from there, i had to unplug it then re-plug it again.
i inserted a disk with Solaris 9 iso trying to rebuild it but nothing... (1 Reply)
Discussion started by: Katkota
1 Replies
8. Solaris
Hi,
I just got a new Ultra 5 and replaced the CD-ROM with an LG DVD-ROM (approved and listed in Sun HCL). Got the DVD-ROM installed to install Solaris 10. Im just learning and new to Solaris installation.
When I insert a Solaris 10 DVD I see that it gets mounted and File Manager opens and... (8 Replies)
Discussion started by: greypilgrim
8 Replies
9. Solaris
I am trying to get an old Ultra 45 to boot and it is stuck in a loop. I cannot get anything to come up on a monitor, so when I hook up a serial connection to the TTYa interface I see the following output:
@(#)OBP 4.21.2 2005/12/22 17:17 Sun Ultra 45 Workstation
Clearing TLBs
Loading... (0 Replies)
Discussion started by: Madrox72
0 Replies
10. UNIX for Beginners Questions & Answers
Hi all,
I've got a Sun ultra 30 workstation. the Nvram battery died so I replaced it. I reprogrammed the mac address using the mlpl command all that so it booted without error. But for some reason I was trying to boot via the network. So I did a STOP A and boot disk1 which is the alias for my SCSI... (2 Replies)
Discussion started by: robbo007
2 Replies
MFI(4) BSD Kernel Interfaces Manual MFI(4)
NAME
mfi -- LSI Logic & Dell MegaRAID SAS RAID controller
SYNOPSIS
mfi* at pci? dev ? function ?
DESCRIPTION
The mfi driver provides support for the MegaRAID SAS family of RAID controllers, including:
- Dell PERC 5/e, PERC 5/i, PERC 6/e, PERC 6/i
- Intel RAID Controller SRCSAS18E, SRCSAS144E
- LSI Logic MegaRAID SAS 8208ELP, MegaRAID SAS 8208XLP, MegaRAID SAS 8300XLP, MegaRAID SAS 8308ELP, MegaRAID SAS 8344ELP, MegaRAID
SAS 8408E, MegaRAID SAS 8480E, MegaRAID SAS 8708ELP, MegaRAID SAS 8888ELP, MegaRAID SAS 8880EM2, MegaRAID SAS 9260-8i
- IBM ServeRAID M1015, ServeRAID M5014
These controllers support RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 50 and RAID 60 using either SAS or SATA II drives.
Although the controllers are actual RAID controllers, the driver makes them look just like SCSI controllers. All RAID configuration is done
through the controllers' BIOSes.
mfi supports monitoring of the logical disks in the controller through the bioctl(8) and envstat(8) commands.
EVENTS
The mfi driver is able to send events to powerd(8) if a logical drive in the controller is not online. The state-changed event will be sent
to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8)
HISTORY
The mfi driver first appeared in NetBSD 4.0.
BSD
March 22, 2012 BSD