Old 10-10-2019
OSR6 has automatic device configuration. It should have found the second disk by itself . Did you run the bios raid configurator and change the raid1 pair to be system drive 1 instead of 0.
This User Gave Thanks to jgt For This Post:
 

10 More Discussions You Might Find Interesting

1. SCO

ultra 320 scsi raid controller driver for sco 5.0.6

I am facing a problem to install sco 5.0.6 in Dell Power Edge SC1420 which raid controller is ultra 320 scsi raid controller . how/from where to download the ultra 320 scsi raid controller driver for sco 5.0.6. Plz help with any idea karzon (1 Reply)
Discussion started by: karzon
1 Replies

2. SCO

driver needed for hp smartarry p200i sas raid controller

recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
Discussion started by: prakrithi
3 Replies

3. Solaris

RAID controller needed for SVM?

hi this may be a very stupid question, but im quite new to Solaris (gonna buid my first system, Solaris 10 on x86 system, connected to other windows systems in a home network) i wanna put a RAID 5 system in there to back up my other systems at home; iv read that its really so easy with SVM to... (4 Replies)
Discussion started by: Landser
4 Replies

4. Hardware

Problem with External Raid Controller.

Hi, We have a Sunfire 4150 with On-Board Internal Raid Controller connected to 4 X 146 GB SAS disks. This also has an External Raid Controller (Storagetek Eight-Port, External HBA Model SG-XPCIESAS-R-EXT-Z) connected to a JBOD array ( Storagetek XTA2530 ) which has 5 X 300 GB Hard disk. ... (1 Reply)
Discussion started by: ranjansukumar
1 Replies

5. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

6. AIX

Internal PCI X RAID Controller issue ?

Hello folks, Could someone tell me why I unable to create pdisks for a RAID Array # lscfg | grep scsi + sisscsia0 U787A.001.DPM0707-P1 PCI-X Dual Channel Ultra320 SCSI Adapter + scsi0 U787A.001.DPM0707-P1-T10 PCI-X Dual Channel Ultra320 SCSI Adapter... (12 Replies)
Discussion started by: filosophizer
12 Replies

7. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

8. SCO

How to change raid controller driver ? (hardware change)

Hello I'm trying to virtualize an instance of Sco Unix 5.0.5 in VirtualBox (called VM-A) , but sco I have problems set to launch with the new raid controller . The physical machine has a raid controller adaptec (alad driver) but VirtualBox uses buslogic (blc driver) What ... (3 Replies)
Discussion started by: flako
3 Replies

9. Red Hat

Separate HDD test using RAID controller

Hello, I am using Red Hat 2.6.23.1 with RAID 6 controller (card). (When I use "cat /proc/partitions" I do not see the separate HDDs in the RAID, I see one drive for the RAID itself, as it is considered 1 large drive.) I used a "dd" check to test my RAID drive speed and found it was a bit slow,... (7 Replies)
Discussion started by: Dbugy
7 Replies

10. SCO

SCO 5.0.7 driver for HP SmartArray P410i Controller on Proliant DL380 G7?

Hi I hope this is the right forum. I am attempting to install SCO 5.0.7 on a Proliant DL380 G7 with a Smart Array P410I Controller. I need a driver for this. Can anybody point me to a download? Thanks in anticipation. (12 Replies)
Discussion started by: Stuart1946
12 Replies
diskd(1)						      General Commands Manual							  diskd(1)

Name
       diskd - disk daemon; wait for disk to be inserted

Note
       This  manpage has been automatically generated from fdutils's texinfo documentation.  However, this process is only approximative, and some
       items, such as cross-references, footnotes and indices are lost in this translation process.  Indeed, these items have no appropriate  rep-
       resentation  in	the  manpage  format.  Moreover, only the items specific to each command have been translated, and the general information
       about fdutils has been dropped in the manpage version.  Thus I strongly advise you to use the original texinfo doc.

       *      To generate a printable copy from the texinfo doc, run the following commands:

		     ./configure; make dvi; dvips fdutils.dvi

       *      To generate a HTML copy,	run:

		     ./configure; make html

	      A pre-made HTML can be found at: `http://www.tux.org/pub/knaff/fdutils'

       *      To generate an info copy (browsable using emacs' info mode), run:

		     ./configure; make info

       The texinfo doc looks most pretty when printed or as HTML.  Indeed, in the info version certain examples are difficult to read due  to  the
       quoting conventions used in info.

Description
       The diskd command has the following syntax:

	  diskd [-d drive] [-i interval] [-e command]

       Diskd  waits for a disk to be inserted into a given drive, and then either executes the command or exits. This program can be used to auto-
       matically mount a disk as soon as it is inserted.

Warning
       This program works by switching the motor on for a very short interval, and then seeking to track -1. This might  damage  hardware  in  the
       long  run.  Amigas,  which  also  use these techniques, are known for having problems with their disk drives no longer spinning up properly
       after a few month of usage.

Options
       -d drive
	      Selects the drive to observe for disk insertion. By default, drive 0 (/dev/fd0) is observed.

       -i interval
	      Selects the polling interval. The interval is given in tenths of seconds. Default is 10 (one second).

       -e command
	      Gives the command to be executed when a disk is inserted. If no command is given the program simply exits.  Typically,  the  command
	      mounts the disk. It can be a shell scripts which probes for several filesystems and disk geometries until it succeeds.

Bugs
       *      Automatic  unmounting  cannot yet be handled. It is indeed not enough to scan for disk removal, because when the disk is removed, it
	      is already too late: There might be some buffers needing flushing.  However, the fdmountd program  allows  automatic  unmounting	by
	      using the SYNC mount options, which switches off write buffering (see section  fdmount).

       *      The drive motor is running all the time, and on some computers, the drive led flickers at each time the drive is polled.

See Also
       Fdutils' texinfo doc

fdutils-5.5							      03Mar05								  diskd(1)
All times are GMT -4. The time now is 05:02 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy