06-21-2019
I'll start by stating that I'm not an AIX person and I'm not familiar with the RAID controller you have there. I am a storage person.
However, with a part number of ST3300656SS that is not a disk manufactured by IBM; it is OEM'd from Seagate.
I'm well aware that Seagate disks of the exact same part number can have a slightly different LBA count and when the LBA count is less than the existing RAID members, the RAID controller refuses to configure it. So just be aware and don't fall for that one.
Check that the LBA's on the disk you replaced is at least equal, or more than, the existing RAID members.
EDIT: The total LBA's (Logical blocks) are usually written on the disk label.
Last edited by hicksd8; 06-21-2019 at 02:38 PM..
These 2 Users Gave Thanks to hicksd8 For This Post:
10 More Discussions You Might Find Interesting
1. Solaris
Dear Friends,
I need to configure T5240 with Internal SAS RAID HBA(SG-XPCIESAS-R-INT-Z).. T5240 uses 8 hard disks... From the documents of RAID card I have found that I need to create a jump start server to include three packages SUNWaac, StorMan, SUNWgccruntime if Im using solaris10 5/08...
... (5 Replies)
Discussion started by: nicktrix
5 Replies
2. Solaris
We have a dual-controller StorEdge 3320 disk array with 5 disks (each 320 MB). Four disks have been set up in a RAID-5 configuration with the remaining disk acting as a hot spare. There is a single logical drive which has been partitioned into 3 slices.
The disk array is to be simultaneously... (14 Replies)
Discussion started by: StarSol
14 Replies
3. AIX
May I know how can I add a new SSA pdisk into array and become usable hdisk? I have inserted a 36GB SSA disk into enclosure and done the "cfgmgr" and I can see it already been regconized as pdisk47.
I would like to make it a system disk in order for me to add to my volume group. Please let me... (3 Replies)
Discussion started by: kwliew999
3 Replies
4. Solaris
Hi,
I`m on SunFire480R with Solaris 10. Disk in rootdg group failed, so it was replaced. However, I cannot make Veritas initalise the replaced disk:
# vxdctl enable
# vxdisk list c1t0d0s2
Device: c1t0d0s2
devicetag: c1t0d0
type: auto
flags: online error private autoconfig... (1 Reply)
Discussion started by: masloff
1 Replies
5. UNIX for Dummies Questions & Answers
Hi,
Is there an easy way to find the disk-type from the command line or with another api ? sdparm works for SAS but not for SATA, hdparm works for SATA but not SAS.
Thanks (1 Reply)
Discussion started by: coderd
1 Replies
6. Ubuntu
Hi,
a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced.
here is how I did that.
1) created identical partition table on the new disk.
2) attached the mirrors using md commands.
The whole procedure is given... (5 Replies)
Discussion started by: busyboy
5 Replies
7. Linux
Hi,
a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced.
here is how I did that.
1) created identical partition table on the new disk.
2) attached the mirrors using md commands.
The whole procedure is given below:... (2 Replies)
Discussion started by: busyboy
2 Replies
8. Red Hat
I need to add a VMware virtual disk to the 99-oracle-asmdevices.rules file but the OS is not assigning a WWID to the disk. It has been fdisk'd and a single partition created.
What TAG inside the file needs to be added? the Program scsi-id does not work for some reason. latest patches... (0 Replies)
Discussion started by: mrmurdock
0 Replies
9. Filesystems, Disks and Memory
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Discussion started by: terrya
1 Replies
10. AIX
Hello,
I would like to check how many SAS disks and its size per disk for the whole power system. As per my understanding, if we assign the SAS controller to LPAR, then we can see the disk in lpar smitty command.
How can we check from the Power machine(physical ones) as well? I think the... (5 Replies)
Discussion started by: Phat
5 Replies
LEARN ABOUT NETBSD
arcmsr
ARCMSR(4) BSD Kernel Interfaces Manual ARCMSR(4)
NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller
SYNOPSIS
arcmsr* at pci? dev ? function ?
DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation:
- ARC-1110 PCI-X 4 Port SATA RAID Controller
- ARC-1110ML PCI-X 4 Port SATA RAID Controller
- ARC-1120 PCI-X 8 Port SATA RAID Controller
- ARC-1120ML PCI-X 8 Port SATA RAID Controller
- ARC-1130 PCI-X 12 Port SATA RAID Controller
- ARC-1130ML PCI-X 12 Port SATA RAID Controller
- ARC-1160 PCI-X 16 Port SATA RAID Controller
- ARC-1160ML PCI-X 16 Port SATA RAID Controller
- ARC-1170 PCI-X 24 Port SATA RAID Controller
- ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller
- ARC-1202 PCI Express 2 Port SATA RAID Controller
- ARC-1210 PCI Express 4 Port SATA RAID Controller
- ARC-1220 PCI Express 8 Port SATA RAID Controller
- ARC-1230 PCI Express 12 Port SATA RAID Controller
- ARC-1230ML PCI Express 12 Port SATA RAID Controller
- ARC-1231ML PCI Express 12 Port SATA RAID Controller
- ARC-1260 PCI Express 16 Port SATA RAID Controller
- ARC-1260ML PCI Express 16 Port SATA RAID Controller
- ARC-1261ML PCI Express 16 Port SATA RAID Controller
- ARC-1280 PCI Express 24 Port SATA RAID Controller
- ARC-1280ML PCI Express 24 Port SATA RAID Controller
- ARC-1680 PCI Express 8 Port SAS RAID Controller
- ARC-1680LP PCI Express 8 Port SAS RAID Controller
- ARC-1680i PCI Express 8 Port SAS RAID Controller
- ARC-1680x PCI Express 8 Port SAS RAID Controller
- ARC-1681 PCI-X 8 Port SAS RAID Controller
These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives.
arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands.
Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or
RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8).
When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until
the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol-
lowing command (once the initialization is finished):
$ scsictl scsibus0 scan any any
The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the
bioctl(8) command.
EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed
event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8)
HISTORY
The arcmsr driver first appeared in NetBSD 5.0.
AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines.
BSD
March 3, 2008 BSD