06-19-2019
Ldom guest volumen problem t8 Solaris 11
hello to everyone. im new member here.
i have a problem with a guest ldom on solaris 11 sparc in a T8. I need to access to disk vds assigned to guest domain but from control domain.
I want to modify a parameter in inittab of the guest domain because start guest domain give me problems with other systems online
How Can i mount this volume in Control Domain?
The configuration in the guest domain is:
DISK
NAME VOLUME TOUT ID DEVICE SERVER MPGROUP
sys sys@primary-vds0 0 disk@0 primary
The configuration in Control Domain is:
rpool/ldoms 10G 38G 3K none
rpool/ldoms/sys 51G 4G 3G -
system disk of ldom guest are volumen of rpool:
/dev/zvol/dsk/rpool/ldoms/sys
Thank u for all.
8 More Discussions You Might Find Interesting
1. Solaris
Hi Folks,
I am used to writing scripts to get info by running commands at local zones level from their respective global zone by using zlogin <localzone> "command>" while remaining at the global zone level.
Can the same be done with Guest LDoms while remaining at the control LDOM level?
... (4 Replies)
Discussion started by: momin
4 Replies
2. Solaris
Solaris for Sparc 11.1 with the latest patches. Created a Guest LDOM with two vnet's net0 and net1, installed a guest whole root, ip exclusive zone that I want to be able to utilize DHCP. I have been able to create the zone but unable to get it to boot because I am unable to assign an anet to it.... (4 Replies)
Discussion started by: os2mac
4 Replies
3. Solaris
Apologies if this is the wrong forum..
I have some LDOMs running on a Sparc server. I copied the disk0 file from one chassis over to another, stopped the ldom on the source system and started it on the 2nd one. All fine. Shut it down and flipped back. We then did a fair bit of work on the... (4 Replies)
Discussion started by: tommyq
4 Replies
4. Solaris
Hello,
I am trying to install Solaris 10 on a newly created LDom. Here are the commands I ran to create the LDom:
ldm add-domain ldg2
ldm add-vcpu 8 ldg2
ldm add-memory 2g ldg2
ldm add-vnet vnet2 primary-vsw0 ldg2
ldm add-vdsdev /dev/dsk/c0t5000CCA01535E20Cd0s0 vol2@primary-vds0
ldm... (8 Replies)
Discussion started by: bstring
8 Replies
5. Solaris
Hi People,
I have been trying to learn solaris ldoms, have created one on a T2000 and get the following error when try to install it off DVD
WARNING: /virtual-devices@100/channel-devices@200/disk@1: Communication error with Virtual Disk Server using Port 0. Retrying
If anyone could help... (8 Replies)
Discussion started by: callmebob
8 Replies
6. Solaris
Hi,
There is LDOM Guest where I need to expand /u02 file systems on it.
It is residing on a Solaris 11 Hypervisor (Primary Domain).
The storage is expanded on vdisk presented to Hypervisor.
I need steps to expand the /u02 on LDOM Guest. (2 Replies)
Discussion started by: vidya_sagar2003
2 Replies
7. UNIX for Beginners Questions & Answers
I'm really stuck here. I've created an LDOM on a SPARC T4-1 with Solaris 11.4 to run a copy of Linux for SPARC. I got the Linux ISO installed and Linux itself installed and booted OK. The only thing is is that there's no networking available in the Linux guest.
This question is basically the... (7 Replies)
Discussion started by: Michele31416
7 Replies
8. Solaris
I have a Sun T4-1 running Solaris 11.4 with a static IP 192.168.0.183. On this machine is a Solaris 10 LDOM with a static IP of 192.168.0.78. The other day I had to stop the LDOM to do a memory reconfigure. When I rebooted it I got an error that the IP 192.168.0.78 was already in use and so... (4 Replies)
Discussion started by: Michele31416
4 Replies
XPCI(4) BSD/xen Kernel Interfaces Manual XPCI(4)
NAME
xpci -- Xen frontend paravirtualized PCI pass-through driver
SYNOPSIS
xpci* at xenbus?
pci* at xpci?
DESCRIPTION
The xpci driver is the frontend part of the PCI pass-through functionality that can be used by Xen guest domains to communicate with PCI
devices.
From a guest point of view, xpci is similar to a pci(4) bus, except that the guest talks with the PCI backend driver instead of the real
physical device directly.
When the host domain is NetBSD, the xpci driver is backed by a pciback(4) driver within the dom0.
SEE ALSO
pci(4), pciback(4), xenbus(4)
HISTORY
The xpci driver first appeared in NetBSD 5.1.
AUTHORS
The xpci driver was written by Manuel Bouyer <bouyer@NetBSD.org>.
SECURITY CONSIDERATIONS
As PCI passthrough offers the possibility for guest domains to send arbitrary PCI commands to a physical device, this has direct impact on
the overall stability and security of the system. For example, in case of erroneous or malicious commands, the device could overwrite physi-
cal memory portions, via DMA.
BSD