03-08-2019
Thanks Bakunin, for that brilliant explanation, I wished I could be so clear...
I want to point out the very last paragraph is crucial! as more than 75% of the issues I encounter are related to that paragraph, usually when migrating disk bays or servers in a hurry ( time frame to respect...) you go to the vital first to get thing working fast and when the pressure drop remember that you havent finished.. to finalise you need those both WWPNs to be effective, only if you are unlucky you have an issue before and chances you find yourself in this very same situation... In other words when doing this sort of operations be sure you have check with the SAN team that all is configured and correct before lets say, reboot after a patching, or moving the VM, it sounds silly but often you having your schedules and issues, are not always aware of what the other team may have done meanwhile that may have a side effects...
9 More Discussions You Might Find Interesting
1. AIX
Want to configure IBM raid strorage but the aix 5L cds do not have the drivers for the fibre channels. The machine is RS/6000. I have gone to IBM downlaodable sites but i can't find the drivers? help pliz:mad: (4 Replies)
Discussion started by: Zim-Aix-Guru
4 Replies
2. AIX
Hello,
I have two systems that are being prepared to be SAN attached ..
can anyone tell me any specific checks I should perform prior to the cards being installed...
I am aware of firmware / OS level and relevant drivers, is there anything else?
thanks
Chris. (8 Replies)
Discussion started by: chlawren
8 Replies
3. AIX
Hello,
Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter.
It is similar to virtual scsi adapter.
In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies
4. Solaris
Hi ,
I have wrtitten a C program that issues USCSICMD ioctl call to the tape devices attached on solaris sparc 10. I was able to get the required information from all SCSI tape devices attached using the utility. But, whenever it is run on FC attached tape drives , the program returns an error... (0 Replies)
Discussion started by: naveen448
0 Replies
5. AIX
hi
i have two aix servers and I was asked to setup a secure shell between the two servers using the sybase user. Can any one let me know how to do this (2 Replies)
Discussion started by: newtoaixos
2 Replies
6. Hardware
We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice?
Thanks in advance. (1 Reply)
Discussion started by: atahmass
1 Replies
7. AIX
Hello,
Just a quick question
Usually from a PSERIES if you want to connect to IBM SAN Storage
you connect the IBM SAN Storage through a SAN Switch
something like this
---
however my question
Can you connect
from Pseries directly to San Storage without SAN Switch
what would be... (8 Replies)
Discussion started by: filosophizer
8 Replies
8. Solaris
Hi
I had power issue that affected a server, in which I had power ON the server SPARC T1-B3 running solaris 10.
After power on the system stops at ok prompt, them I issued the following commands:
{0} ok setenv auto-boot? false
auto-boot? = false
{0} ok reset-all
SPARC T3-1B,... (10 Replies)
Discussion started by: fretagi
10 Replies
9. Solaris
Hi,
One of my Netra 240 went into hung state and I had to reboot it. I powered it off and tried booting it again but unsuccessful. It is not connected to SAN and have local disks. Not able to boot in failsafe mode too.
There are two disks of 72GB, both are mirrored in SVM. It complains about... (5 Replies)
Discussion started by: solaris_1977
5 Replies
REBOOT(8) System Manager's Manual REBOOT(8)
NAME
reboot - stopping and restarting the system
SYNOPSIS
/sbin/reboot [ -lqnhdarsfRD ]
/sbin/halt [ -lqndars ]
/sbin/fastboot [ -lqndarsRD ]
DESCRIPTION
2.11BSD is started by placing it in memory at location zero and transferring to its entry point. Since the system is not reentrant, it is
necessary to read it in from disk or tape each time it is to be boot strapped.
Rebooting a running system: When the system is running and a reboot is desired, shutdown(8) is normally used to stop time sharing and put
the system into single user mode. If there are no users then /sbin/reboot can be used without shutting the system down first.
Reboot normally causes the disks to be synced and allows the system to perform other shutdown activities such as resynchronizing hardware
time-of-day clocks. A multi-user reboot (as described below) is then initiated. This causes a system to be booted and an automatic disk
check to be performed. If all this succeeds without incident, the system is then brought up for multi-user operation.
Options to reboot are:
-l Don't try to tell syslogd(8) what's about to happen.
-q Reboot quickly and ungracefully, without shutting down running processes first.
-n Don't sync before rebooting. This can be used if a disk or the processor is on fire.
-h Don't reboot, simply halt the processor.
-d Dump memory onto the dump device, usually part of swap, before rebooting. The dump is done in the same way as after a panic.
-a Have the system booter ask for the name of the system to be booted, rather than immediately booting the default system (/unix).
-r Mount the root file system as read only when the system reboots. This is not supported by the kernel in 2.11BSD.
-s Don't enter multi-user mode after system has rebooted - stay in single user mode.
-f Fast reboot. Omit the automatic file system consistency check when the system reboots and goes multi-user. This is accomplished by
passing a fast reboot flag on to the rebooting kernel. This currently prevents the use of -f flag in conjunction with the -h (halt)
flag.
-D Set the autoconfig(8) debug flag. This is normally not used unless one is debugging the autoconfig program.
-R Tells the kernel to use the compiled in root device. Normally the system uses the device from which it was booted as the
root/swap/pipe/dump device.
Reboot normally places a shutdown record in the login accounting file /usr/adm/wtmp. This is inhibited if the -q or -n options are
present. Note that the -f (fast reboot) and -n (don't sync) options are contradictory; the request for a fast reboot is ignored in this
case.
Halt and fastboot are synonymous with ``reboot -h'' and ``reboot -f'', respectively.
Power fail and crash recovery: Normally, the system will reboot itself at power-up or after crashes if the contents of low memory are
intact. An automatic consistency check of the file systems will be performed, and unless this fails, the system will resume multi-user
operations.
SEE ALSO
autoconfig(8), sync(2), utmp(8), shutdown(8), syslogd(8)
3rd Berkeley Distribution May 24, 1996 REBOOT(8)