Operating Systems AIX [ASK] - AIX Fibre Channel behavior Post 303031938 by Phat on Friday 8th of March 2019 02:41:19 AM
Old 03-08-2019
Hi Bakunin,

You are right. I'm not so understand well the FC work, zoning work, and IBM virtualization work.
Just want to know the FC port work and multipath(redundant) work.

We talk about another aspect. For example, if you have 2 FC cards, each has 2 ports. So 4 ports are connected to the LUN. Assuming that, 3 ports failed and we have only 1 port. So we still can see the LUN? and in case 2 ports failed, we can see the LUN? In regard redundant, with 4 line connected to LUN, the system is only down if 4 lines were down/broken, even if 1 line is still available, the system still running. Please correct me this.

I'm surprised is that in my environment I can see the LUN on 2 still-working FC cards, but not boot device. After 1 more FC is up again, I can see. So confused about this.
 

9 More Discussions You Might Find Interesting

1. AIX

Fibre channel drivers on RS/6000 aix 5L

Want to configure IBM raid strorage but the aix 5L cds do not have the drivers for the fibre channels. The machine is RS/6000. I have gone to IBM downlaodable sites but i can't find the drivers? help pliz:mad: (4 Replies)
Discussion started by: Zim-Aix-Guru
4 Replies

2. AIX

Install Fibre Card AIX 5.3

Hello, I have two systems that are being prepared to be SAN attached .. can anyone tell me any specific checks I should perform prior to the cards being installed... I am aware of firmware / OS level and relevant drivers, is there anything else? thanks Chris. (8 Replies)
Discussion started by: chlawren
8 Replies

3. AIX

Power6 Virtual Fibre Channel Adapter

Hello, Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter. It is similar to virtual scsi adapter. In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies

4. Solaris

USCSICMD ioctl calls for Fibre Channel(FC) devices on Solaris 10?

Hi , I have wrtitten a C program that issues USCSICMD ioctl call to the tape devices attached on solaris sparc 10. I was able to get the required information from all SCSI tape devices attached using the utility. But, whenever it is run on FC attached tape drives , the program returns an error... (0 Replies)
Discussion started by: naveen448
0 Replies

5. AIX

Setting up a secure channel with AIX

hi i have two aix servers and I was asked to setup a secure shell between the two servers using the sybase user. Can any one let me know how to do this (2 Replies)
Discussion started by: newtoaixos
2 Replies

6. Hardware

Fibre Channel HBA recommendations?

We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice? Thanks in advance. (1 Reply)
Discussion started by: atahmass
1 Replies

7. AIX

AIX - Fibre Adapter and IBM Storage

Hello, Just a quick question Usually from a PSERIES if you want to connect to IBM SAN Storage you connect the IBM SAN Storage through a SAN Switch something like this --- however my question Can you connect from Pseries directly to San Storage without SAN Switch what would be... (8 Replies)
Discussion started by: filosophizer
8 Replies

8. Solaris

Fibre channel link down on booting Solaris server

Hi I had power issue that affected a server, in which I had power ON the server SPARC T1-B3 running solaris 10. After power on the system stops at ok prompt, them I issued the following commands: {0} ok setenv auto-boot? false auto-boot? = false {0} ok reset-all SPARC T3-1B,... (10 Replies)
Discussion started by: fretagi
10 Replies

9. Solaris

Fibre Channel link not ready on Netra 240

Hi, One of my Netra 240 went into hung state and I had to reboot it. I powered it off and tried booting it again but unsuccessful. It is not connected to SAN and have local disks. Not able to boot in failsafe mode too. There are two disks of 72GB, both are mirrored in SVM. It complains about... (5 Replies)
Discussion started by: solaris_1977
5 Replies
cmdisklock(1m)															    cmdisklock(1m)

NAME
cmdisklock - manage Serviceguard cluster lock devices. SYNOPSIS
cmdisklock check path cmdisklock [-f] reset path DESCRIPTION
cmdisklock is a tool to check the current state of a Serviceguard cluster lock device. It can also be used to reset the state of the clus- ter lock device. The need to reset the cluster lock device state could arise if the cluster lock device is replaced or becomes corrupt. A cluster lock device can be either an HP-UX LVM cluster lock or a cluster lock LUN device. HP-UX LVM cluster locks exist only on a disk in an LVM volume group. Cluster lock LUNs exist only on disks dedicated to cluster lock. cmdisklock is useful for checking either type of cluster lock and for re-initializing cluster lock LUN devices after a failure or corruption. NOTE To restore an HP-UX LVM cluster lock, use vgcfgrestore. cmdisklock will fail until vgcfgrestore is run, and cmdisklock is unnecessary as long as vgcfgbackup was done after the cluster lock was initialized. See the Managing Serviceguard manual for details. The syntax of the path option depends on the type of lock. For HP-UX LVM cluster lock disks, the syntax is VG:PV (for example: /dev/vglock:/dev/dsk/c0t0d2). For cluster lock LUN disks, the path is the disk device path. For example, /dev/sdd1 (on Linux) or /dev/dsk/c0t1d2 (on HP-UX). Options cmdisklock supports the following options: check Check the current state of the cluster lock device and report the results. reset Reset (initialize) the state of the cluster lock device. This operation should only be performed on a cluster lock LUN device. For HP-UX LVM cluster lock, use vgcfgrestore as documented in the Managing Serviceguard manual. After performing a reset, a check can be used to verify that the lock is cleared. EXAMPLES
If the cluster lock LUN device becomes corrupted and the cluster is up, messages like the following will appear in syslog. Mar 15 12:20:41 usb cmdisklockd[17599]: WARNING: Cluster lock LUN /dev/dsk/c0t1d2 is corrupt: bad label. Until this situation is cor- rected, a single failure could cause all nodes in the cluster to crash. Mar 15 12:20:41 usb cmdisklockd[17599]: After ensuring that all active nodes in the cluster have logged this message, run 'cmdisklock reset /dev/dsk/c0t1d2' to repair Mar 15 12:20:41 usb cmdisklockd[17599]: Cluster lock disk /dev/dsk/c0t1d2 is inaccessible Once the above messages appear in syslog on all running nodes, the following command will re-initialize the cluster lock LUN: ucd:/> cmdisklock reset /dev/dsk/c0t1d2 WARNING: Cluster lock LUN /dev/dsk/c0t1d2 is corrupt: bad label. Until this situation is corrected, a single failure could cause all nodes in the cluster to crash. After ensuring that all active nodes in the cluster have logged this message, run 'cmdisklock reset /dev/dsk/c0t1d2' to repair /dev/dsk/c0t1d2 is inaccessible Resetting cluster lock device /dev/dsk/c0t1d2 Cluster lock reset completed /dev/dsk/c0t1d2 is accessible cleared After the lock is restored, a message like the following appears in syslog: Mar 15 12:23:11 usb cmdisklockd[17599]: Cluster lock disk /dev/dsk/c0t1d2 is accessible WARNINGS
CAUTION For cluster lock LUN, reset is a potentially destructive operation. While cmdisklock checks for known volume manager and file system use (overridden by -f), it does not validate that the device to be reset is actually used by any cluster. If -f is used on the wrong device file, loss of data may result. CAUTION Care should be taken when doing a reset when the cluster is active as there is a remote possibility that the cluster will partition right when this command is run and both nodes could end up thinking they have successfully acquired the lock. To avoid this situation, make sure cmcld has logged a message in syslog on all running nodes saying the device is inaccessble, before performing a reset. Note that it is safe to run cmdisklock when the cluster is down. RETURN VALUE
cmdisklock returns the following values: 0 Successful completion. 1 The disk is inaccessible or is not recognized as a cluster lock. AUTHOR
cmdisklock was developed by HP. SEE ALSO
cmapplyconf(1m), cmviewcl(1m), vgcfgbackup(1m), vgcfgrestore(1m) Requires Optional Serviceguard Software cmdisklock(1m)
All times are GMT -4. The time now is 03:10 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy