I have encountered the issue with the hard disk, the disk is failed and need to replace by the new one.
As my understanding, this is just to take out the failed disk and insert the new ones, and that's all.
But the third party hardware vendor said, there should be another procedure in AIX for this activity.
I have attached the screenshot for disk checking.
Hi,
Other than df -k, is there any command that will tell me all physical hard drives installed on the system as well as the size of each one?
I'm using AIX 5.1
Thanks, (3 Replies)
I am new to being a Unix admin and have a question about replacing some hardware. I have a K class box using HP-UX 10.20 with three disks. Two of the drives are in one logical volume. Every 3 or 4 days, the syslog is showing that one of these drives is experiencing "POWERFAILED" and then recovering... (6 Replies)
Hi people, I have been using my disk for quite a long time but the other day I heard the drive making some noise and had to restart the system again. But when I did that the disk would not boot and I fear that the data might be deleted or lost. So, if you people have any know about the ways to get... (1 Reply)
Hi people,
I have been using my disk for quite a long time but the other day I heard the drive making some noise and had to restart the system again. But when I did that the disk would not boot and I fear that the data might be deleted or lost. So, if you people have any know about the ways to... (2 Replies)
hi all,
have a solaris 9 OS and a SAN disk which used to work fine is not getting picked up by my machine. can anyone point out things to check in order to troubleshoot this ??
thanks in advance. (3 Replies)
hi
I've a fresh installation of SCO 5.0.7 on the IDE hard disk.
For SCSI hard disk I can declare, for example blc disk driver using:
# mkdev hd 0 SCSI-0 0 blc 0but it works for IDE hard disk? (3 Replies)
in red hat 4, 5 any one know any commands or any scritps to monitor HP DL 380 G5/6 server and trigger alarm when hard disk failed.
thanks for all support
---------- Post updated at 02:45 PM ---------- Previous update was at 12:00 PM ----------
does HP ProLiant Support Pack support is... (4 Replies)
Hi all,
I'm kind of new to programming in Linux & c/c++. I'm currently writing a FileManager using Ubuntu Linux(10.10) for Learning Purposes. I've got started on this project by creating a loopback device to be used as my virtual hard disk. After creating the loop back hard disk and mounting it... (23 Replies)
Hello to all,
Im having a new task in a new world (AIX - IBM Servers)
I have an IBM Server (Type - 9111-285 very old one) with one Hard disk (73 GB 10 K) with AIX 5.x, and I need to clone the existing disk to another with the same specifications.
Could you please give me some advice in order... (7 Replies)
Discussion started by: trevian3969
7 Replies
LEARN ABOUT OSF1
volreattach
volreattach(8) System Manager's Manual volreattach(8)NAME
volreattach - Reattaches disk drives that have once again become accessible
SYNOPSIS
/usr/sbin/volreattach [-rb] [accessname...]
/usr/sbin/volreattach -c accessname
OPTIONS
The volreattach utility has the following options: Calls the volrecover utility to attempt to recover stale plexes of any volumes on the
failed disk. Performs the reattach operation in the background. Checks whether a reattach is possible. No operation is performed, but the
name of the disk group and disk media name at which the disk can be reattached is displayed.
DESCRIPTION
The volreattach utility attempts to reattach disks using the same disk group and media names they had before detachment.
This operation may be necessary if a disk has a transient failure, or if some disk drivers are unloaded or unloadable when the Logical
Storage Manager is started, causing disks to enter the failed state.
If the problem is fixed, the volreattach command can be used to reattach the disks without plexes being flagged as stale, as long as the
reattach happens before any volumes on the disk are started.
The volreattach command is called from the voldiskadm menus as part of disk recovery.
The volreattach utility tries to find a disk with a disk group and disk ID matching that of the disk(s) being reattached. If the matching
disk is found, the reattach operation may still fail if the original cause (or some other cause) for the disk failure still exists.
EXIT CODES
A zero exit status is returned if it is possible to perform a reattach. Otherwise, non-zero is returned.
SEE ALSO volintro(8), voldiskadm(8), volrecover(8)volreattach(8)