02-18-2019
Moderator's Comments:
|
|
moved to AIX forum
|
|
10 More Discussions You Might Find Interesting
1. AIX
I am trying to run the lscod command against an HMC that has managed system names with spaces.
Tried enclosing the managed system names in quotes; single and double.
How do I get the command to run?
ssh hmcname lscod -m 'managed system 1' -t cap -r proc -c cuod
Thanks,
~Donavon (0 Replies)
Discussion started by: djlerman
0 Replies
2. AIX
I started the AIX install with a fiber channel disk, and let it run:
restricted by GSA ADP Schedule Contract with IBM Corp.
. . . . . << End of copyright notice for perfagent.tools >>. . . .
... (2 Replies)
Discussion started by: Gideon1a
2 Replies
3. AIX
Hi,
We have a P595 machine with a dual port Fiber card per VIOs.
We have two VIOs in the box.
VIO1: ---> 2 port Fiber Card
VIO2: ---> 2 port Fiber Card
One port on each fiber card is utilized. Connected to SAN switches. We are getting all disks from SAN both for VIOs and LPARs.
Now... (0 Replies)
Discussion started by: aixromeo
0 Replies
4. AIX
Hi,
I am executing below commands on HMC. I see that there is only colon ":" in output.
Can someone please help why I am getting ":" in output? Why I am not getting proper output?
xxxxx@yyyyhmc1:~> viosvrcmd -m PCC-p590#2-SN024D8F0 -p ppvio1 -c "lsmap -all"
:xxxxx@yyyyhmc1:~> viosvrcmd... (0 Replies)
Discussion started by: marya
0 Replies
5. AIX
Hi all,
i would like to know if it's possible upgrade AIX 5.3 to 6.1 on a LPAR without use the HMC.
so i would like to know if i must use the console to do it or i can do all from the up&running system on LPAR.
Thanks in advance.
Mario (4 Replies)
Discussion started by: Zio Bill
4 Replies
6. AIX
I am trying to generate a report to track dlpar operation performed on a MS and was wondering if anyone has done this before.
I can get history from HMC using lssvcevents , but this does not give me details as to what quantity was added or removed .
Any thoughts ?
Thanks (3 Replies)
Discussion started by: mk8570
3 Replies
7. AIX
Hi ,
I would like to access the cd drive of , i have power series server , and have lpars .
I try to install AIX in an lpar via HMC, but it can't access the cd drive.
how i can make installtion or make the the cd drive accessible in hmc or in power series server?
Thanks in advance (2 Replies)
Discussion started by: prpkrk
2 Replies
8. AIX
Hi,
For installing aix on power series , do i need to install hmc first?
or i can connect hmc after?
Rgs, (7 Replies)
Discussion started by: prpkrk
7 Replies
9. AIX
Trying to get the IP address of the HMC connected to some servers running AIX 6 and 7. I thought this would be as easy as running 'lsrsrc IBM.MCP IPAddresses', but when I run that command, the resource is empty. Is there some where else I should be looking, or is there a reason why this resource... (5 Replies)
Discussion started by: acascianelli
5 Replies
10. AIX
hello
P6 was managed by HMC, tried to install on it VIOS 2.2.6
and got this error message
Hosting requires a hosting partition -- boot not permitted
vios-4 - imgbb.com
then after creating an lpar in HMC got this message
B2001230
vios-3 - imgbb.com
anyone know how to solve this... (3 Replies)
Discussion started by: filosophizer
3 Replies
LEARN ABOUT DEBIAN
sdl_keysym
SDL_keysym(3) SDL API Reference SDL_keysym(3)
NAME
SDL_keysym - Keysym structure
STRUCTURE DEFINITION
typedef struct{
Uint8 scancode;
SDLKey sym;
SDLMod mod;
Uint16 unicode;
} SDL_keysym;
STRUCTURE DATA
scancode Hardware specific scancode
sym SDL virtual keysym
mod Current key modifiers
unicode Translated character
DESCRIPTION
The SDL_keysym structure is used by reporting key presses and releases since it is a part of the SDL_KeyboardEvent.
The scancode field should generally be left alone, it is the hardware dependent scancode returned by the keyboard. The sym field is
extremely useful. It is the SDL-defined value of the key (see SDL Key Syms. This field is very useful when you are checking for certain key
presses, like so:
.
.
while(SDL_PollEvent(&event)){
switch(event.type){
case SDL_KEYDOWN:
if(event.key.keysym.sym==SDLK_LEFT)
move_left();
break;
.
.
.
}
}
.
.
mod stores the current state of the keyboard modifiers as explained in SDL_GetModState. The unicode is only used when UNICODE translation
is enabled with SDL_EnableUNICODE. If unicode is non-zero then this a the UNICODE character corresponding to the keypress. If the high 9
bits of the character are 0, then this maps to the equivalent ASCII character:
char ch;
if ( (keysym.unicode & 0xFF80) == 0 ) {
ch = keysym.unicode & 0x7F;
}
else {
printf("An International Character.
");
}
UNICODE translation does have a slight overhead so don't enable it unless its needed.
SEE ALSO
SDLKey
SDL
Tue 11 Sep 2001, 23:00 SDL_keysym(3)