01-29-2019
Quote:
LPAR. I thought that since it already has working NetApp LUNS/disks that it would narrow thing down. I'll be happy to provide anything that might help, but I don't know what might be relevant.
vbe is right, that could be many things - and then some. If it doesn't even show up in the
lsdev i'd first think about the zoning to be wrong. That the system has already some NetApp disks configured shows that the driver part is correct. It still might be possible that the new disk is coming from a different storage device and that is not correctly configured to serve LUNs to the system.
I hope this helps.
bakunin
10 More Discussions You Might Find Interesting
1. AIX
Hi All,
Can anyone explain me the meanning of the following errors:
LABEL: SC_DISK_ERR2
IDENTIFIER: B6267342
Description
DISK OPERATION ERROR
Probable Causes
DASD DEVICE
Failure Causes
DISK DRIVE
DISK DRIVE ELECTRONICS
Recommended Actions
PERFORM PROBLEM DETERMINATION... (1 Reply)
Discussion started by: gianlu
1 Replies
2. UNIX for Dummies Questions & Answers
getting "NFS mount: netapp : RPC: Program not registered" error
searched the site but none of the fixes from previous threads are helping (2 Replies)
Discussion started by: calamine
2 Replies
3. Solaris
Previously , i remove the disk by
#vxdg -g testdg -k rmdisk testdg02
But i got error when i -k adddisk
bash-2.03# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 auto:none - - online invalid
c0t1d0s2 auto:none ... (1 Reply)
Discussion started by: waibabe
1 Replies
4. UNIX for Advanced & Expert Users
I have the below script which has been written to retrieve files from tape drive i.e. TSM server. Now i have to write the script using UNIX commands for retrieve operation but I am not able to proceed. The script is:
#!/usr/local/bin/expect -f
set timeout 1800
set file
spawn $env(SHELL)... (0 Replies)
Discussion started by: hrsaurav
0 Replies
5. UNIX for Dummies Questions & Answers
Firstly, system setup -
HP900 K460, 3 internal hard drives that make up the system volume group(vg00) no software mirroring
HP-ux version 11.00
2 Nike 20 raid arrays attached, fully populated with 40 4gb hot swap drives(All used in production environment)
I have 3 disks that make up my... (0 Replies)
Discussion started by: rees_a
0 Replies
6. UNIX for Dummies Questions & Answers
Hi Guys,
I have a failing 4gb (c0t5d0) drive that contains lvol4 -8 on hp-ux. It's not the boot disk but is part of VG00 volume group. Within that group, I have a disk (c0t4d0) of the same size that has 1 lvol on it for swap(4gb) I also have a seperate 1.5 gb swap volume on another physical disk... (1 Reply)
Discussion started by: rees_a
1 Replies
7. AIX
Hi Guys,
I tried running the firefox in AIX 6.1 and got the below error..
-bash-3.00# firefox
Could not load program /usr/mozilla/firefox/firefox-bin:
Could not load module /usr/mozilla/firefox/libxul.so.
Dependent module /usr/lib/libgtk-x11-2.0.a(libgtk-x11-2.0.so.0) could not... (0 Replies)
Discussion started by: kkeng808
0 Replies
8. Shell Programming and Scripting
#!/bin/ksh for AIX
used=0
mount=${1:-"/mountpoint"}
threshold=${2:-80}
#message="hello"
#SUBJECT="Disk Space Alert"
#EMAIL="xyz@abcinc.com"
used=`df -k $mount | grep % | awk '{print $5}' | sed 's/%//g'`
#echo "Free Space available under \"$mount\" is `expr 100 - $used`%.\n">$message
... (6 Replies)
Discussion started by: rajeshw61
6 Replies
9. AIX
hello folks,
I have a 300GB ROOTVG volume groups with one filesystem /backup having 200GB allocated space
Now, I cannot alt disk clone or mirrorvg this hdisk with another smaller disk. The disk size has to be 300GB; I tried alt disk clone and mirrorvg , it doesn't work. you cannot copy LVs as... (9 Replies)
Discussion started by: filosophizer
9 Replies
10. AIX
I have 2 AIX 6.1 systems running on PowerPCs - production and .. .everything else. :p . Until the installation of a TLS certificate in an application, some copying of files ("cloning an environment") and upgrading a listener, sending a kill -15 worked on any script/application, so long as we were... (6 Replies)
Discussion started by: Mrucker
6 Replies
CCD(4) BSD Kernel Interfaces Manual CCD(4)
NAME
ccd -- Concatenated disk driver
SYNOPSIS
pseudo-device ccd [count]
DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk.
This document assumes that you're familiar with how to generate kernels, how to properly configure disks and pseudo-devices in a kernel con-
figuration file, and how to partition disks.
Note that the 'raw' partitions of the disks must not be combined. Each component partition should be offset at least one cylinder from the
beginning of the component disk. This avoids potential conflicts between the component disk's disklabel and the ccd's disklabel. The kernel
will only allow component partitions of type FS_CCD. But for now, it allows partition of all types since some port lacks support of an on-
disk BSD disklabel. The partition of FS_UNUSED may be rejected because device driver of component disk will refuse it.
In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file:
pseudo-device ccd 4 # concatenated disk devices
The count argument is how many ccds memory is allocated for at boot time. In this example, no more than 4 ccds may be configured.
A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0.
If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase performance. Since the interleave factor is
expressed in units of DEV_BSIZE, one must account for sector sizes other than DEV_BSIZE in order to calculate the correct interleave. The
kernel will not allow an interleave factor less than the size of the largest component sector divided by DEV_BSIZE.
Note that best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different
disk types.
Also note that the total size of concatenated disk may vary depending on the interleave factor even if the exact same components are concate-
nated. And an old on-disk disklabel may be read after interleave factor change. As a result, the disklabel may contain wrong partition
geometry and will cause an error when doing I/O near the end of concatenated disk.
There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information.
WARNINGS
If just one (or more) of the disks in a non-mirrored ccd fails, the entire file system will be lost.
FILES
/dev/{,r}ccd* ccd device special files.
SEE ALSO
config(1), MAKEDEV(8), ccdconfig(8), fsck(8), mount(8), newfs(8)
HISTORY
The concatenated disk driver was originally written at the University of Utah.
BSD
March 5, 2004 BSD