06-19-2018
Sun shipped some mobo's in COD (Capacity on Demand) mode which means they won't work without a license. Have you got one of those? Do you know the machine history?
Search the web for:
"Capacity on Demand"
This User Gave Thanks to hicksd8 For This Post:
9 More Discussions You Might Find Interesting
1. AIX
Hello:
NOOB here. I attempted to use smit mkcd. Failed on first attempt, not enough space. 2nd attempt tried to place iso on /usr, not enough space there. Cleanup ran for about 5 minutes after aborting. Now AIX won't boot. LCD display on 7029-6E3 says: 0517 MOUNT /USR. Attempted to boot from CD... (11 Replies)
Discussion started by: bbird
11 Replies
2. Solaris
Hi,
I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies
3. Solaris
Hi i 've a M5000 running 2 domains in my Lab with following hardconf
SPARC Enterprise M5000; Memory_Size:128 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies
4. Solaris
Please advise. Thank you
bash-3.00# cd /usr/sunvts/bin/
bash-3.00# ls
bios.bin iobushangscript.sh stopsunvts vtsprobe
cmos.bin javabridge.jar sunlink vtsreportgenerate
dispatcher loadVtsServer svmVolDiskList vtstalk
env6test... (6 Replies)
Discussion started by: incredible
6 Replies
5. Hardware
I have an M5K with disk issues I'm trying to troubleshoot, and it's causing me some confusion. I know the host has four on-board HDDs, but the format command's output shows c0t0d0, c0t1d0, c3t0d0, and c3t1d0. cfgadm -al shows c0t3d0 as the DVD-ROM drive, and c1 and c2 as SAN disks. Confused yet?
... (2 Replies)
Discussion started by: desertdenizen
2 Replies
6. IP Networking
I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip.
it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out.
so my question is,
any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies
7. Solaris
I have an m5000 that Is down.
I have access to XSCF>
and was able to get to the ok prompt.
However, on
>ok boot
it failed to boot.
erred with :
svc.startd: svc:/system/device/fc-fabric:default: Method "/lib/svc/method/fc-fabric" failed due to signal KILL.
Nov 29... (3 Replies)
Discussion started by: goya
3 Replies
8. AIX
A team member installed the wrong version of License Code on a Power 740 system used in our Development environment.
The system will no longer boot.
Does anyone have IBM documentation or experience to share on recovering a system that currently reports "Unsupported License Code version... (1 Reply)
Discussion started by: kevinedailey
1 Replies
9. UNIX for Beginners Questions & Answers
Can anyone offer any advice on how to modify the script below to work on a new system we have, that has no graphics capability? We admin the system through a serial RAS device. I've tried running the below script through the RAS and through an ssh -X session. It failed with something like "GTK... (3 Replies)
Discussion started by: yelirt5
3 Replies
LEARN ABOUT HPUX
icapnotify
icapnotify(1M) icapnotify(1M)
NAME
icapnotify - Test email connectivity to HP for Instant Capacity (iCAP) systems. Request a confirmation response email from HP. Turn config-
uration change notification and asset reporting on or off.
SYNOPSIS
icapnotify <reply_address>
icapnotify -a on|off
icapnotify -n on|off
Obsolescent:
icod_notify <reply_address>
icod_notify -a on|off
icod_notify -n on|off
DESCRIPTION
When a reply_address is specified, sends an asset report via email to HP, root, and the specified email address. Confirmation email is
sent from HP to the specified reply email address indicating that HP received the asset report email.
Note that asset reporting is optional but can be useful for viewing complexwide asset information at the HP Utility Pricing Solutions por-
tal (http://www.hp.com/go/icap/portal).
The deprecated command provides identical functionality to the command and is maintained for backward compatibility.
For detailed information on email configuration and requirements, see the located at /usr/share/doc/icapUserGuide.pdf.
Options
The command recognizes these options and arguments:
-a on|off Turns email asset reporting on or off. This option is used to specify if the Instant Capacity software should send asset
reports to HP via email. The command displays the present setting for this option.
-n on|off Turns configuration change notification on or off. If specified on, executing the command results in a configuration
change notification email sent to the system contact email address summarizing any configuration change. Configuration
change notification email can be turned off by specifying off. Configuration change notifications are not sent if the
system contact email address is not set.
EXTERNAL INFLUENCES
Environment Variables
o LANG determines the locale to use for the locale categories when both LC_ALL and the corresponding environment variable (begin-
ning with LC_) do not specify a locale. If LANG is not set or is set to the empty string, a default of C is used (see lang(5)).
o LC_CTYPE determines the interpretation of single- and multiple-byte characters.
o LC_MESSAGES determines the language in which messages are displayed.
If any internationalization variable contains an invalid setting, icapnotify behaves as if all internationalization variables are
set to C (see environ(5)).
International Code Set Support
Single- and multiple-byte character code sets are supported.
RETURN VALUE
The command exits with one of these values:
0 Command succeeded.
>0 Command failed; error message sent to STDERR.
EXAMPLES
Test email connectivity with HP by sending an asset report to HP, root , and super_user@corp.com, and request a confirmation email from HP
to be sent to super_user@corp.com:
icapnotify super_user@corp.com
Turn email asset reporting on:
icapnotify -a on
Turn email asset reporting off:
icapnotify -a off
Turn configuration change notification on:
icapnotify -n on
Turn configuration change notification off:
icapnotify -n off
AUTHOR
was developed by HP.
SEE ALSO
icapmodify(1M), icapstatus(1M), icapmanage(1M), icapd(1M), icap(5).