06-19-2018
no support since its older. just a company that swaps parts. I did try the power on each domain and same result , did no reset fault, what command does that? I will try and find it.
9 More Discussions You Might Find Interesting
1. AIX
Hello:
NOOB here. I attempted to use smit mkcd. Failed on first attempt, not enough space. 2nd attempt tried to place iso on /usr, not enough space there. Cleanup ran for about 5 minutes after aborting. Now AIX won't boot. LCD display on 7029-6E3 says: 0517 MOUNT /USR. Attempted to boot from CD... (11 Replies)
Discussion started by: bbird
11 Replies
2. Solaris
Hi,
I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies
3. Solaris
Hi i 've a M5000 running 2 domains in my Lab with following hardconf
SPARC Enterprise M5000; Memory_Size:128 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies
4. Solaris
Please advise. Thank you
bash-3.00# cd /usr/sunvts/bin/
bash-3.00# ls
bios.bin iobushangscript.sh stopsunvts vtsprobe
cmos.bin javabridge.jar sunlink vtsreportgenerate
dispatcher loadVtsServer svmVolDiskList vtstalk
env6test... (6 Replies)
Discussion started by: incredible
6 Replies
5. Hardware
I have an M5K with disk issues I'm trying to troubleshoot, and it's causing me some confusion. I know the host has four on-board HDDs, but the format command's output shows c0t0d0, c0t1d0, c3t0d0, and c3t1d0. cfgadm -al shows c0t3d0 as the DVD-ROM drive, and c1 and c2 as SAN disks. Confused yet?
... (2 Replies)
Discussion started by: desertdenizen
2 Replies
6. IP Networking
I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip.
it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out.
so my question is,
any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies
7. Solaris
I have an m5000 that Is down.
I have access to XSCF>
and was able to get to the ok prompt.
However, on
>ok boot
it failed to boot.
erred with :
svc.startd: svc:/system/device/fc-fabric:default: Method "/lib/svc/method/fc-fabric" failed due to signal KILL.
Nov 29... (3 Replies)
Discussion started by: goya
3 Replies
8. AIX
A team member installed the wrong version of License Code on a Power 740 system used in our Development environment.
The system will no longer boot.
Does anyone have IBM documentation or experience to share on recovering a system that currently reports "Unsupported License Code version... (1 Reply)
Discussion started by: kevinedailey
1 Replies
9. UNIX for Beginners Questions & Answers
Can anyone offer any advice on how to modify the script below to work on a new system we have, that has no graphics capability? We admin the system through a serial RAS device. I've tried running the below script through the RAS and through an ssh -X session. It failed with something like "GTK... (3 Replies)
Discussion started by: yelirt5
3 Replies
LEARN ABOUT CENTOS
hpipower
hpipower(1) OpenHPI hpipower(1)
NAME
hpipower - This sample openhpi application exercises HPI Power Management APIs.
SYNOPSIS
hpipower [ -D nn ] [-N host[:port]] [-C <cfgfile>] [ -d -p -r -u -X -h] [ -b n ]
hpipower [--domain=nn] [--host=host[:port]] [--cfgfile=file]
[--power-down --power-up --reset --unattended --debug --help] [--blade=n ]
DESCRIPTION
hpipower searches the Resource Presence Table (RPT) for resources with Power Capability. It sends the requested power action to the
selected target.
If no domain or host is selected, hpipower uses the default domain as specified in the openhpiclient.conf file.
OPTIONS
Help Options:
-h, --help
Show help options
Application Options:
-d, --power-down
Power down target object
-p, --power-up
Power on target object
-r, --reset
Reset target object
-u, --unattended
Unattended
-b n, --blade=n
Specify blade n (1...n)
-D nn, --domain=nn
Select domain id nn
-X, --debug
Display debug messages
-N "host[:port]", --host="host[:port]"
Open session to the domain served by the daemon at the specified URL (host:port). This option overrides the OPENHPI_DAEMON_HOST and
OPENHPI_DAEMON_PORT environment variables. If host contains ':' (for example IPv6 address) then enclose it in square brackets. For
example: "[::1]" or "[::1]:4743".
-C "file", --cfgfile="file"
Use passed file as client configuration file. This option overrides the OPENHPICLIENT_CONf environment variable.
SEE ALSO
hpi_shell
hpialarms hpifan hpireset hpitop
hpidomain hpigensimdata hpisensor hpitree
hpiel hpiiinv hpisettime hpiwdt
hpievents hpionIBMblade hpithres hpixml
ohdomainlist ohhandler ohparam
AUTHORS
Authors of this man page:
Peter D Phan (pdphan@users.sourceforge.net)
Ulrich Kleber (ulikleber@users.sourceforge.net)
Anton Pak (avpak@users.sourceforge.net)
3.2.1 2011-09-20 hpipower(1)