SPARC: Accessing the system console, ALOM, ILOM, XSCF |
Have you tried telnet'ing to this port? It can accept connections from ssh clients or telnet clients but NOT both.
If another user can connect via ssh locally then it would look like a network issue so maybe no point in physically visiting the server. Could it be that another user is already connected to the console port and the setup of your network means that you get a 'timeout' response?
Last edited by hicksd8; 10-26-2017 at 06:29 AM..
This User Gave Thanks to hicksd8 For This Post:
10 More Discussions You Might Find Interesting
1. Solaris
While entering to service mode on XSCF i getting following error
XSCF> service
Account is not enabled for service mode.
What could be the reason for this ? (5 Replies)
Discussion started by: fugitive
5 Replies
2. Solaris
Hi all
A couple of new M5000 servers will be arriving soon and I need to work out how to configure the underlying domains.
It will come with 4 x CPUS, 32 Gb of memory, 4 x HD, 2 x IOtrays.
Reading the XSCF manual, I can configure the item into 2 domains, something about uni / quad xsb.... (9 Replies)
Discussion started by: sbk1972
9 Replies
3. Solaris
Hi, I've got an issue here: After I logon to the xscf prompt of this Sun M5000 and did 'XSCF> version -c xcp', the xscf prompt disappeared. I can't get it back and can't log out.
exit
rebootxscf
logout
#.
#>
#>
~#
~#
exit
sendbreak
exit
I tried to set the Mode Switch to the service... (3 Replies)
Discussion started by: aixlover
3 Replies
4. Solaris
Hi,
I've updated a few M3000s to new firmware without any hassle, but on one of them the following is happening:
XSCF> getflashimage -u wayner ftp://10.16.122.200/tftpboot/IKXCP1102.tar.gz
Error: insufficient free space
Any idea how to delete whatever old firmware is on there so I can... (7 Replies)
Discussion started by: cabaiste
7 Replies
5. Solaris
Hi,
I've configured this Sun M5000 to use two system domains (added a second domain to it). The following is the info about the settings. The showdevices command can't show devices on domain 1 because Solaris is not loaded on it yet.
My question: How can I confirm the hardware devices such as... (5 Replies)
Discussion started by: aixlover
5 Replies
6. Emergency UNIX and Linux Support
Hi All,
I have SPARC T4-4 connected with XSCF console. By mistake console user name is set to "root" instead of "sunadmin" (This is what we keep as standard). How can I change it ? Please help me
-> show /SP/users/root
/SP/users/root
Targets:
ssh
Properties:
role... (1 Reply)
Discussion started by: solaris_1977
1 Replies
7. Solaris
Hi,
I would appreciate some help.
I remotely access, across a VPN, an M5000 and when I connect to the XSCF I can then access the OS using console -d0 and then I can get to the console.
The problem I have is that I need to run something which will take many hours and I can't run it in the... (6 Replies)
Discussion started by: giles.cardew
6 Replies
8. Solaris
Trying to update my M5000 firmware. trying to mount my USB to upload firmware and getting the following message.
XSCF> getflashimage -v file:///media/usb_msd/FFXCP1115.tar.gz
Free space: 97MB
Making sure mount point is clear
umount: /media/usb_msd is not mounted (according to mtab)
Trying... (2 Replies)
Discussion started by: soupbone38
2 Replies
9. Solaris
Hi,
I'm planning to upgrade the XSCF firmware on an M5000, and have a question regarding the OBP part of the upgrade. At the moment, the system looks like this:
XCP0 (Current): 1100
OpenBoot PROM : 02.18.0000
XSCF : 01.10.0000
root@server01 # /usr/sbin/prtconf -V
OBP 4.24.15... (3 Replies)
Discussion started by: badoshi
3 Replies
10. Solaris
Hi all,
I understand SP is a separate processor use for management purposes.
I understand XSCF is the management facility (similar to IDRAC, ILOM etc).
I understand that we can create multiple domains in a SPARC machine (something like VM) and we can install OS in it.
I am able to use... (4 Replies)
Discussion started by: javanoob
4 Replies
LEARN ABOUT CENTOS
telnet-probe
TELNET-PROBE(1) General Commands Manual TELNET-PROBE(1)
NAME
telnet-probe - lightweight telnet-like port probe
SYNOPSIS
$PCP_BINADM_DIR/telnet-probe [-c] [-v] host port
DESCRIPTION
telnet-probe allows the pmdashping(1) daemons to establish connections to arbitrary local and remote service-providing daemons so that
response time and service availability information can be obtained.
The required host and port number arguments have the same meaning as their telnet(1) equivalents.
The -c option causes telnet-probe to perform a connect(2) only. This skips the read(2) and write(2) exercise that would otherwise be done
after connecting (see below).
The -v option causes telnet-probe to be verbose while operating.
Once the telnet connection has been established, telnet-probe reads from stdin until end-of-file, and writes all the input data to the tel-
net connection. Next, telnet-probe will read from the telnet connection until end-of-file, discarding whatever data it receives. Then
telnet-probe exits.
To operate successfully, the input passed via telnet-probe to the remote service must be sufficient to cause the remote service to close
the connection when the last line of input has been processed, e.g. ending with ``quit'' when probing SMTP on port 25.
By default telnet-probe will not produce any output, unless there is an error in which case a diagnostic message can be displayed (in ver-
bose mode only) and the exit status will be non-zero indicating a failure.
PCP ENVIRONMENT
Environment variables with the prefix PCP_ are used to parameterize the file and directory names used by PCP. On each installation, the
file /etc/pcp.conf contains the local values for these variables. The $PCP_CONF variable may be used to specify an alternative configura-
tion file, as described in pcp.conf(5).
DIAGNOSTICS
If telnet-probe succeeds, then 0 will be returned. If the attempt to establish a connection fails or is terminated, then a non-zero exit
status is returned.
SEE ALSO
PCPintro(1), pmdashping(1), pmie(1), telnet(1), connect(2), read(2) and write(2).