Sponsored Content
Operating Systems Solaris How to identify if disk is attached to SAN and assist in migration.? Post 303001531 by kpatel786 on Sunday 6th of August 2017 03:26:24 PM
Old 08-06-2017
Code:
DEVICE PROPERTIES for disk: /dev/rdsk/c3t60060480000290101499533030374535d0s2
  Vendor:               EMC
  Product ID:           SYMMETRIX
  Revision:             5773
  Serial Num:           1014997E5000
  Unformatted capacity: 43157.812 MBytes
  Read Cache:           Enabled
    Minimum prefetch:   0x0
    Maximum prefetch:   0xffff
  Device Type:          Disk device
  Path(s):

  /dev/rdsk/c3t60060480000290101499533030374535d0s2
  /devices/scsi_vhci/ssd@g60060480000290101499533030374535:c,raw
   Controller           /devices/pci@780/pci@0/pci@8/SUNW,qlc@0/fp@0,0
    Device Address              5006048452a63ec9,60
    Host controller port WWN    2100001b3212ffda
    Class                       primary
    State                       ONLINE
   Controller           /devices/pci@7c0/pci@0/pci@9/SUNW,qlc@0/fp@0,0
    Device Address              5006048452a63ec6,60
    Host controller port WWN    2100001b3212ccdb
    Class                       primary
    State                       ONLINE

The above command show to paths from two different HBA,s it is similar to other devices as well.

This is a VM host the vfstab output is
Code:
cat /etc/vfstab
#device         device          mount           FS      fsck    mount   mount
#to mount       to fsck         point           type    pass    at boot options
#
fd      -       /dev/fd fd      -       no      -
/proc   -       /proc   proc    -       no      -
/dev/dsk/c1t0d0s1       -       -       swap    -       no      -
/dev/dsk/c1t0d0s0       /dev/rdsk/c1t0d0s0      /       ufs     1       no      logging
/dev/dsk/c1t0d0s3       /dev/rdsk/c1t0d0s3      /var    ufs     1       no      logging
/dev/dsk/c1t0d0s4       /dev/rdsk/c1t0d0s4      /home   ufs     2       yes     logging
/dev/dsk/c1t0d0s5       /dev/rdsk/c1t0d0s5      /var/crash      ufs     2       yes     logging
/devices        -       /devices        devfs   -       no      -
sharefs -       /etc/dfs/sharetab       sharefs -       no      -
ctfs    -       /system/contract        ctfs    -       no      -
objfs   -       /system/object  objfs   -       no      -
swap    -       /tmp    tmpfs   -       yes     -

I am planning to do online storage migration following below steps, it has one ldom.
  1. Remove 1 fc
  2. Assign the luns from the new storage
  3. scan the devices
  4. Mirror it ( dont know the command )
  5. Break the mirror and remove the old storage lun
  6. attach the 2nd fc.

Will this work ?

Last edited by rbatte1; 08-07-2017 at 08:22 AM.. Reason: Converted textual numbers list to formatted numbered list with LIST=1 tags
 

10 More Discussions You Might Find Interesting

1. HP-UX

SAN migration

Hi, I'm going to be involved in a migration of SAN islands to one big SAN. I've not worked with SANs before and I'm not sure how to approach this. I suspect the disk devices on the HP servers are going to change, when the EVA's and servers are plugged into this new Cisco 9509 switch. Any... (0 Replies)
Discussion started by: Hils
0 Replies

2. Solaris

SAN connection - configuring fibre attached hard drive

Hi All, I recently got a connection to the SAN through a fibre channel on my solaris box: #luxadm -e port /devices/pci@1d,700000/SUNW,qlc@1/fp@0,0:devctl CONNECTED #ls -l /dev/cfg lrwxrwxrwx 1 root root 48 Feb 23 12:31 c4 -> ../../devices/pci@1d,700000/SUNW,qlc@1/fp@0,0:fc I then... (2 Replies)
Discussion started by: dede
2 Replies

3. Red Hat

Identify SAN disks not in use

Hello, How can I identify SAN disks not in use by the OS? Thank you. (8 Replies)
Discussion started by: asanchez
8 Replies

4. Solaris

Identify Boot from SAN

How to identify the server is BOOT FROM SAN. Also how one can find from which device it is booted? Thanks Rahul Double post, continued here (0 Replies)
Discussion started by: rahul.kurumkar
0 Replies

5. Red Hat

Identify Boot from SAN

Hi, I have many servers all of these are boot from SAN. Can anybody let me know that how to identify the server is Boot fron SAN and from which device? Thanks Rahul (1 Reply)
Discussion started by: rahul.kurumkar
1 Replies

6. HP-UX

SAN Migration of HP-UX hosts

Hello gurus, I am a SAN Admin - not very familiar with the HPUX administration - so need help with the steps in regards to the migration I need to do at my client place. Environment: Migrating from CX4 to VMAX - using OR/Hot Pull. Here are the steps I have put together - HPUX gurus please... (5 Replies)
Discussion started by: jps460
5 Replies

7. AIX

SAN Migration

Hi all, We are migrating our SAN storage from HSV360 to 3PAR. The system runs aix 6.1 version with HACMP. Please let me know what are requirements from OS side and how are the data copied to the new disks. (10 Replies)
Discussion started by: ElizabethPJ
10 Replies

8. HP-UX

SAN Migration question

Hi, I am very new to HP-UX, and we're going to be doing a SAN migration. We're going to take down the machine, and zone it to the new SAN. My question is, will the device names change and will that interfere with the LVM? If the new disks come in with different device names, how would I... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

9. AIX

AIX - FC Switch migration, SAN Migration question!

I'm New to AIX / VIOS We're doing a FC switch cutover on an ibm device, connected via SAN. How do I tell if one path to my remote disk is lost? (aix lvm) How do I tell when my link is down on my HBA port? Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies

10. Linux

Identify newly attached LUN from NetApp

Hi I need to identify a newly attached LUN from NetApp on a linuxserver running uname -o GNU/Linux I have first run the df -h and got the following: df -h Filesystem Size Used Avail Use% Mounted on /dev/mapper/vg_outsystemdb-lv_root 50G 2.7G 45G ... (3 Replies)
Discussion started by: fretagi
3 Replies
hpfc(7D)							      Devices								  hpfc(7D)

NAME
hpfc - Agilent fibre channel host bus adapter SYNOPSIS
PCI pci103c DESCRIPTION
The hpfc fibre channel host bus adapter is a SCSA compliant nexus driver that supports all Agilent fibre channel host bus adapters, includ- ing the HHBA5100x, HHBA5101x, and HHBA5121x models. Agilent host bus adapters support the fibre channel protocol on private fibre channel arbitrated loops and fabrics. The driver supports up to ten host bus adapters, with a maximum of 125 fibre channel devices on each host bus adapter. The hpfc driver supports a maximum of 256 LUNs per target. The hpfc driver does not support the BIOS Int 13 feature, which enables the booting of an operating system. As a result, you should not install an operating system on devices attached to the hpfc driver. CONFIGURATION
The hpfc driver attempts to configure itself using the information in the /kernel/drv/hpfc.conf configuration file. By default, the driver supports only LUN 0 for each target device. To add multiple LUN support, modify the /kernel/drv/sd.conf file. Before upgrading the hpfc driver, backup the sd.conf file to save customized LUN settings and then use pkgrm(1M) to remove the old version of the driver. The host bus adapter port is initialized to FL_Port when connected to a fabric switch. To change it to F_Port, add the init_as_nport=1 entry to the hpfc.conf file and reboot the system. To conserve system resources, at least one disk drive must be attached to the hpfc driver. If no devices are attached, the driver will not load. FILES
/kernel/drv/hpfc 32-bit ELF kernel module /kernel/drv/sparcv9/hpfc 64-bit ELF kernel module /kernel/drv/hpfc.conf Driver configuration file /kernel/drv/sd.conf SCSI disk configuration file ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |x86, SPARC | +-----------------------------+-----------------------------+ SEE ALSO
luxadm(1M), pkgrm(1M), prtconf(1M), driver.conf(4), attributes(5), ses(7D), ssd(7D) ANSI X3.272-1996, Fibre Channel Arbitrated Loop (FC-AL), ANSI X3.269-1996, Fibre Channel Protocol for SCSI (FCP), ANSI X3.270-1996, SCSI-3 Architecture Model (SAM), Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) SunOS 5.10 10 Oct 2000 hpfc(7D)
All times are GMT -4. The time now is 01:41 PM.