I am new to Sybase Adaptive Server Enterprise/15.7 (ASE) and need some guidance to find the different values in serial format column. It has values with below format which contains 12 digits hexadecimal characters with numbers/alphabets.
Ex:
00:71:48:D1:R6:Z7 --Valid record
3E67E5E334Q8 --invalid as : is not used across 2 digits
How can query be written to identify SERIAL_FORMAT with:-
Total Valid
Invalid
Missing
Bad format
Repeated values
Any help is appreciated.
In addition to what migurus has already said, note that saying that valid records contain 12 hexadecimal digits and then saying that a string containing 17 characters of which 7 are not hexadecimal digits (five colons, an uppercase R, and an uppercase Z) is valid AND saying that a string that doesn't contain colons is invalid brings everything else you've said into question. It is very hard to help you write code to help you test conflicting requirements.
Hello Guys,
I'm new to Shell scripting, and i need someone to help me with this issue:
I'm trying to do a dynamic update query on Sysbase database table using shell script.
Lets say, the Update query is "update Table set id=X" , where X is dynamic value for the loop index.
If the loop is... (10 Replies)
Hello Guys,
Well, using shell script, I'm doing loop on DB query as below:
isql -Usa -Ptest -I /opt/sybase/interfaces << EOF
use testdb
go
declare @i int
select @i = 1
while(@i <= 5)
begin
Insert into TEST values (@i,"Test","TestDesc")
select @i = @i + 1
end
go
EOF
The Issue... (2 Replies)
Hello,
I have three tables.
I need an SQL query (preferably Sybase) that will return all of the stringID values of table B where the following conditions exist:
(1) B.intID = A.intID
(2) B.intID != C.intID
or (B.intID = C.intID and
(C.v1 = 0 or C.v2... (2 Replies)
i'm looking for an installer of Sybase ASE 11.9.2.6 for HP-UX. tried buying from the local distributor but he can only give me the latest version. can anyone point me to where i could possibly get it? (0 Replies)
Team
I am using DBartisan tool for sybase database.
I have a table that has below fields Employee_ID,EMP_Name,First_Nm,Last_Nm,Emp_Designation,Employee's_Manager
is it possible to retrieve hierarchical data based on below fields
Emp_Designation will have Soft Engg,SSE,Team Lead,... (6 Replies)
HI Team
I am using Sybase ASE15.7 version.
Below is the sample column values .
http://abc.lifeline.airs.com/support/
https://xyzbre.lifeline.airs.com/video/
Would like to know how to
Trim http:// and https:// from above list of example
Remove characters after first /
Include only the... (3 Replies)
Hi Team -
I am using Sybase ASE 15.7 version. Below query is throwing an error
stating Error : incorrect syntax near the keyword 'OVER'
SELECT
EMPLOYEE_ID ,
EMPLOYEE ,
Department,
CAST( Salary as DECIMAL( 10, 2 ) ) AS Salary
CAST(AVG( Salary) OVER ( PARTITION... (3 Replies)
Dear Team
I am using Sybase Adaptive Server Enterprise/15.7 (ASE). Trying my luck on SOUNDEX function to get unique records
Though the command works for characters and provides unique code for similar outputs.
But when i try with Starting numbers ( Followed with Street address ) , soundex... (1 Reply)
Dear Team
Please provide suggestion on below query which is used in Sybase Adaptive Server Enterprise/15.7 (ASE).
Query takes more time > 30 Mins to 1 Hr
All required indexes are built
Can we have any efficient approach to get the data retrieval faster for below query.Any help... (0 Replies)
Discussion started by: Perlbaby
0 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)