12-27-2016
The fans are controlled by the service processor due to the enviromental conditions. If something is of with the fans, a firmware update might help.
So updating the ALOM and OBP to latest level might solve your problems.
10 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
Hello,
I have a Supermicro server with a P4SCI mother board running Debian Sarge 3.1. This is the "dmidecode" output related to RAM info:
RAM speed information is incomplete.. "Current Speed: Unknown", is there anyway/soft to get the speed of installed RAM modules? thanks!!
Regards :)... (0 Replies)
Discussion started by: Santi
0 Replies
2. Solaris
Is there a way to check if my Sun box's network interface card is set to 10 or 100 Mbps?
Thanks! (1 Reply)
Discussion started by: FredSmith
1 Replies
3. BSD
Hi all,
Is there any way that I can get some control over th fan in my Evo N400C laptop running OpenBSD 4.0?
Right now the fan is running constantly and it woulf be nice if it could be quiet sometime. (1 Reply)
Discussion started by: Timmy66
1 Replies
4. UNIX for Advanced & Expert Users
SUN DataBase Server (Sunfire v215)
Machine addresses
Server IP:10.8.104.53
Server Mgmt IP:10.8.104.51
Server hostname:memstestdb
OS passwords
root:*********
oracle:*********
ALOM (Admin/Management) Machine IP: 10.8.104.51
ALOM account and password:
admin:s@vi2005
(Note: at the... (2 Replies)
Discussion started by: jai111
2 Replies
5. Filesystems, Disks and Memory
I analysed disk performance with blktrace and get some data:
read:
8,3 4 2141 2.882115217 3342 Q R 195732187 + 32
8,3 4 2142 2.882116411 3342 G R 195732187 + 32
8,3 4 2144 2.882117647 3342 I R 195732187 + 32
8,3 4 2145 ... (1 Reply)
Discussion started by: W.C.C
1 Replies
6. Solaris
would Solaris 10 shutdown automatically if both CPU fans fail? (7 Replies)
Discussion started by: orange47
7 Replies
7. Solaris
I have a sun fire v240 server.
The output of prtdiag -v shows a failed fan.
There are 3 fans for cooling system board.
There is 1 fan for each of the powersupply (There are 2 powersupplies)
From the below output how do i know which fan is bad and whats its location... (3 Replies)
Discussion started by: Tirmazi
3 Replies
8. Hardware
hi all,
kindly help in this matter. Can i check anyone has any experience in removing the CPU fan from its chassis? my fan is spoilt and i wish to replace with other type. See picture below..
http://zone11.codemicroinc.netdna-cdn.com/large_1054367.jpg
---------- Post updated at 05:15 PM... (6 Replies)
Discussion started by: lchunleo
6 Replies
9. Solaris
Hey,
I have a V210 with a failed CPU fan.
The temperature is currently at 84C and I've been asked to wait a few weeks before replacing as its a production system and it cant be shut down yet.
Is it too hot? Do I risk killing the CPU at this temp?
Its been like this for a few weeks now... (5 Replies)
Discussion started by: magarvo
5 Replies
10. Solaris
Hi all,
I got a v215 but the login credentials are unknown. I plug the serial management RS232-RJ45 and get the output on the terminal. I reseted NVRAM and battery but I can't use the default login still. After these operations the output from boot is as such ;
ALOM POST 1.0
Status =... (21 Replies)
Discussion started by: y33t
21 Replies
LEARN ABOUT CENTOS
iprupdate
IPRUPDATE(8) System Manager's Manual IPRUPDATE(8)
NAME
iprupdate - IBM Power RAID adapter/device microcode update utility
SYNOPSIS
iprupdate
iprupdate --debug --check_only --daemon --use-polling --use-uevents
DESCRIPTION
iprupdate is used to update the microcode on IBM storage adapters and the disk units attached to them to a minimum supported level. It can
be run at any time while the ipr device driver is loaded. The utility will check the microcode revision level of each storage adapter/disk
unit on the system and compare it to the microcode revision level that is installed in /etc/microcode, /usr/lib/microcode, and
/lib/firmware. If the microcode level on the adapter/device is below the minimum supported level and the level of the latest image is
newer, the microcode will be updated to the latest level available. It is desired that this be called in the boot process.
OPTIONS
--version
Print the version number of iprupdate
--debug
Enable additional error logging. Enabling this will result in additional errors logging to /var/log/messages.
--check_only
Check if any adapters or disk units are below their minimum supported level.
--daemon
Run as a daemon to handle adapters and devices being hotplugged.
--use-polling
Do not use netlink/uevent notification, but rather poll for adapter and device configuration changes.
--use-uevents
Use netlink/uevent notification rather than polling for adapter and device configuration changes. If not specified, polling will be
used until the first uevent notification appears, then netlink will be used.
AUTHOR
Brian King (brking@us.ibm.com)
February 2005 IPRUPDATE(8)