Seems like Solaris-11 is not compatible/supported for this software. I have installed as per your downloadable link, but it is generating dump. If this is so, I need not go back and remove both SAS cables and plug them on MB "somewhere" and that will bypass RAID controller.
We used kstat on netra240/440 to check if the link is full duplex. So we do something like:
bash-3.00# kstat -pc net bge:1::/'link_duplex'/ | cut -f2
2
The output 2 indicates the link is full duplex. This kind of check worked all right for Netra 240/440 systems.
However, the nxge... (2 Replies)
I 've 2 different T5220 and both are showing different prompts when i ssh to the console.
1. Shows sc> ALOM
2. Shows -> ILOM
as far as i know the T5220 comes with ILOM , so why i 'm seeing 2 different type of console for same tyep of hardware ?
and i found that we... (6 Replies)
Hi,
SC on one of my T5220 is not responding .. it does not show not let me type anything .. what could be the reason for it ? though when i powercycle the box from sc it shows me the system coming up but after that does not let me login thru sc
sc> console -f
Enter #. to return to ALOM. (2 Replies)
We're just about to migrate a large application from an Enterprise 6900 to a pair of T5220s utilising LDOMs. Does anyone have any experience of LDOMs on this kit and can provide any recommendations or pitfalls to avoid?
I've heard that use of LDOMs can have an impact on I/O speeds as it's all... (9 Replies)
Hi,
We have two T5220 servers in our datacentre
one server is showing 64 processors online
and another showing 32 processors online
two are newly purchased, there is no hardware faults in this server
one server has 64gb memory and it shows 64 processors,
and other having 32gb memory and it... (5 Replies)
I have a new T5220 racked at our remote office and the guys who racked it does not know how to configure the SP on the system .. is there any way i can do it remotely ? (1 Reply)
I'm trying to use a V210 (sun4u) configured as a jumpstart server to flash install a number of T5220's (sunv4).
The Facts:
V210 - Solaris 10 (September 2010 Release / not patched)
T5220's - Archive's created using prior (unknown) version of solaris 10.
Flar -i <archive name> shows the... (6 Replies)
Hi Guys and Gals,
Wondering if anyone could help me, tricky one this.
Got a T5220 with a graphics card. When you power it on, it outputs its output to the screen and you can type commands with the keyboard etc.
But no matter what version of Solaris 10 you use, when you do a boot cdrom... (1 Reply)
Hello guys,
can anyone give me some advice on how to perform
clean installation of Solaris 10 on T5220 ?
I am connected with serial management port on the machine,
i have the ok promt and now i should eject the dvdrom to insert
Solaris dvd into and start the clean install.
So how to do that... (3 Replies)
We have one box T5220 which was assigned 2x100G Luns but i have a strange problem if i use powermt display it only shows me one card but cfgadm, fcinfo commands shows 2 dual port cards as up. What could be the reason for it. I already did a re-configure reboot but that didn't help. Can anyone help... (1 Reply)
Discussion started by: fugitive
1 Replies
LEARN ABOUT NETBSD
mlxctl
MLXCTL(8) BSD System Manager's Manual MLXCTL(8)NAME
mlxctl -- Mylex DAC960 family management utility
SYNOPSIS
mlxctl [-f dev] [-v] [-a] status [drive] [...]
mlxctl [-f dev] [-a] detach [drive] [...]
mlxctl [-f dev] [-a] check [drive] [...]
mlxctl [-f dev] rebuild channel:target
mlxctl [-f dev] cstatus
mlxctl [-f dev] rescan
mlxctl [-f dev] config
DESCRIPTION
The mlxctl utility performs status monitoring and management functions for Mylex DAC960 RAID controllers and attached devices.
The following options are available:
-a Apply the action to all drives attached to the controller.
-f dev Specify the control device to use. The default is /dev/mlx0.
-v Increased verbosity.
The following commands are available:
cstatus Display the controller's current status.
status Display the status of the specified drives. This command returns 0 if all drives tested are online, 1 if one or more drives are
critical and 2 if one or more are offline.
rescan Re-scan the logical drive table, and attach or detach devices from the system as necessary.
detach Detach the specified drives. Drives must be unmounted and unopened for this command to succeed.
check Initiate a consistency check and repair pass on a drive that provides redundancy (e.g., RAID1 or RAID5). This command returns imme-
diately. The status command can be used to monitor the progress of the check.
rebuild Rebuild onto the specified physical drive. Note that there can be only one running rebuild operation per controller at any given
time. This command returns immediately. The cstatus command can be used to monitor the progress of the rebuild.
config Write the current system drive configuration to stdout.
EXAMPLES
Display the status of drive ld3 attached to the controller mlx1:
mlxctl -f /dev/mlx1 -v status ld3
SEE ALSO ld(4), mlx(4)HISTORY
The mlxctl command first appeared in NetBSD 1.5.3, and was based on the mlxcontrol utility found in FreeBSD.
BUGS
Modifying drive configuration is not yet supported.
Some commands do not work with older firmware revisions.
Error log extraction is not yet supported.
BSD April 10, 2000 BSD