Cfgmgr Error

Hi,

My AIX server able to detect the LUN's which is mapped from IBM v7k storage, And i allocated one more LUN from HP storage but it's appear two hdisk instead of one and it's showing incorrect LUN ID.

SDDPCM driver already installed on this server.

During cfgmgr, Im getting this message :

Code:
cfgmgr: 0514-621 WARNING: The following device packages are required for
device support but are not currently installed.
devices.fcp.array

please advise on this...

Last edited by rbatte1; 09-19-2016 at 07:26 AM.. Reason: Added CODE tags
 

10 More Discussions You Might Find Interesting

1. AIX

LPAR and CFGMGR

I have a P570 that for some reason is not allowing the P1-T6 NIC to be recognized. I have confirmed from the HMC that it is set for the LPAR, but when I do a cfgmgr, it won't recognize it. It though is recognizing the slot cards just fine which are P1-C3 for one shelf and P1-C3 of another shelf.... (1 Reply)
Discussion started by: LegendMan
1 Replies

2. AIX

cfgmgr and hdisk number allocation

Hi - can anybody tell me what the default behaviour is for cfgmgr when it allocates hdisk numbers to newly discovered disks in the ODM ? I want to add a disk from our FAStT700 SAN disk array and import it on our p-series (AIX 5.2). Problem is we import and export Flashcopy devices fror scripted... (5 Replies)
Discussion started by: fosteria
5 Replies

3. AIX

cfgmgr

Hi All, I remember my old senior mentor in AIX that cfgmgr should not be terminated on your console. Because if it's terminated in the middle, the odm might get corrupted. Is that true for AIX 5.x? Regards, itik (1 Reply)
Discussion started by: itik
1 Replies

4. AIX

cfgmgr: Filesets missing

Hi all, I have a System i server with a couple of AIX LPARs. One of the LPARs owns a dual-channel scsi adapter to which I connect a tape library (IBM TS3100) and a DVD Drive. I had some problems to get the Tape Library detected but finally I got it: rmt0 Available 03-08-01-4,0 IBM 3580... (1 Reply)
Discussion started by: wendelalexis
1 Replies

5. AIX

Dual port NIC, cfgmgr

OS: AIX 6.1 The host has a dual port NIC installed and when I went to run `cfgmgr -v` to configure it I got an error showing device packages are missing from the install: `cfgmgr -v` on 10.15.xx.xxx cfgmgr: 0514-621 WARNING: The following device packages are required for device support but... (3 Replies)
Discussion started by: b1f30
3 Replies

6. AIX

cfgmgr in my aix box

Hi When I run cfgmgr -v in my aix box I get the below error : cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.loopback My oslevel is 6100-06-02-1044 Please assist. Please use and tags when... (3 Replies)
Discussion started by: samsungsamsung
3 Replies

7. UNIX for Dummies Questions & Answers

> 5 ")syntax error: operand expected (error token is " error

im kinda new to shell scripting so i need some help i try to run this script and get the error code > 5 ")syntax error: operand expected (error token is " the code for the script is #!/bin/sh # # script to see if the given value is correct # # Define errors ER_AF=86 # Var is... (4 Replies)
Discussion started by: metal005
4 Replies

8. AIX

cfgmgr: 0514-621 WARNING

Dear all i have a sun SL500 tape library attached to my AIX box while issue the command cfgmgr i have the below issue test>cfgmgr cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.fcp.changer please... (3 Replies)
Discussion started by: thecobra151
3 Replies

9. Solaris

Rpcinfo: can't contact portmapper: RPC: Authentication error; why = Failed (unspecified error)

I have two servers with a fresh install of Solaris 11, and having problems when doing rpcinfo between them. There is no firewall involved, so everything should theoretically be getting through. Does anyone have any ideas? I did a lot of Google searches, and haven't found a working solution yet. ... (2 Replies)
Discussion started by: christr
2 Replies

10. AIX

Time taking for cfgmgr on dual VIO

Hi, From the man page, cfgmgr configures devices and optionally installs device software by running the programs specified in the Configuration Rules object class and it is not dependent on platform . Are there any fundamental differences impacting the speed of cfgmgr on a stand-alone and... (5 Replies)
Discussion started by: Sachin1987
5 Replies
cmdisklock(1m)															    cmdisklock(1m)

NAME
cmdisklock - manage Serviceguard cluster lock devices. SYNOPSIS
cmdisklock check path cmdisklock [-f] reset path DESCRIPTION
cmdisklock is a tool to check the current state of a Serviceguard cluster lock device. It can also be used to reset the state of the clus- ter lock device. The need to reset the cluster lock device state could arise if the cluster lock device is replaced or becomes corrupt. A cluster lock device can be either an HP-UX LVM cluster lock or a cluster lock LUN device. HP-UX LVM cluster locks exist only on a disk in an LVM volume group. Cluster lock LUNs exist only on disks dedicated to cluster lock. cmdisklock is useful for checking either type of cluster lock and for re-initializing cluster lock LUN devices after a failure or corruption. NOTE To restore an HP-UX LVM cluster lock, use vgcfgrestore. cmdisklock will fail until vgcfgrestore is run, and cmdisklock is unnecessary as long as vgcfgbackup was done after the cluster lock was initialized. See the Managing Serviceguard manual for details. The syntax of the path option depends on the type of lock. For HP-UX LVM cluster lock disks, the syntax is VG:PV (for example: /dev/vglock:/dev/dsk/c0t0d2). For cluster lock LUN disks, the path is the disk device path. For example, /dev/sdd1 (on Linux) or /dev/dsk/c0t1d2 (on HP-UX). Options cmdisklock supports the following options: check Check the current state of the cluster lock device and report the results. reset Reset (initialize) the state of the cluster lock device. This operation should only be performed on a cluster lock LUN device. For HP-UX LVM cluster lock, use vgcfgrestore as documented in the Managing Serviceguard manual. After performing a reset, a check can be used to verify that the lock is cleared. EXAMPLES
If the cluster lock LUN device becomes corrupted and the cluster is up, messages like the following will appear in syslog. Mar 15 12:20:41 usb cmdisklockd[17599]: WARNING: Cluster lock LUN /dev/dsk/c0t1d2 is corrupt: bad label. Until this situation is cor- rected, a single failure could cause all nodes in the cluster to crash. Mar 15 12:20:41 usb cmdisklockd[17599]: After ensuring that all active nodes in the cluster have logged this message, run 'cmdisklock reset /dev/dsk/c0t1d2' to repair Mar 15 12:20:41 usb cmdisklockd[17599]: Cluster lock disk /dev/dsk/c0t1d2 is inaccessible Once the above messages appear in syslog on all running nodes, the following command will re-initialize the cluster lock LUN: ucd:/> cmdisklock reset /dev/dsk/c0t1d2 WARNING: Cluster lock LUN /dev/dsk/c0t1d2 is corrupt: bad label. Until this situation is corrected, a single failure could cause all nodes in the cluster to crash. After ensuring that all active nodes in the cluster have logged this message, run 'cmdisklock reset /dev/dsk/c0t1d2' to repair /dev/dsk/c0t1d2 is inaccessible Resetting cluster lock device /dev/dsk/c0t1d2 Cluster lock reset completed /dev/dsk/c0t1d2 is accessible cleared After the lock is restored, a message like the following appears in syslog: Mar 15 12:23:11 usb cmdisklockd[17599]: Cluster lock disk /dev/dsk/c0t1d2 is accessible WARNINGS
CAUTION For cluster lock LUN, reset is a potentially destructive operation. While cmdisklock checks for known volume manager and file system use (overridden by -f), it does not validate that the device to be reset is actually used by any cluster. If -f is used on the wrong device file, loss of data may result. CAUTION Care should be taken when doing a reset when the cluster is active as there is a remote possibility that the cluster will partition right when this command is run and both nodes could end up thinking they have successfully acquired the lock. To avoid this situation, make sure cmcld has logged a message in syslog on all running nodes saying the device is inaccessble, before performing a reset. Note that it is safe to run cmdisklock when the cluster is down. RETURN VALUE
cmdisklock returns the following values: 0 Successful completion. 1 The disk is inaccessible or is not recognized as a cluster lock. AUTHOR
cmdisklock was developed by HP. SEE ALSO
cmapplyconf(1m), cmviewcl(1m), vgcfgbackup(1m), vgcfgrestore(1m) Requires Optional Serviceguard Software cmdisklock(1m)
All times are GMT -4. The time now is 05:18 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy