Sponsored Content
Operating Systems AIX Power5 9133-55A Serial Console connection issue Post 302966598 by bakunin on Sunday 14th of February 2016 05:38:21 AM
Old 02-14-2016
Quote:
Originally Posted by Devyn
The thought that the HMC connection might disable the console port seamed like an odd thing to do to me so didn't consider to test it, even though it crossed my mind. I also tried to unplug the ethernet cables from the HMC ports to see if the serial ports would be reenabled but it doesnt' work in reverse. Once you power the Power5 server on or plug in the HMC cables, either action has the effect of permanently disabling the serial ports. Strange design but ok.
Both the serial connection and the network connection (to the HMC) are handled by the "Service processor" (which is about the same as a PCs ILO.board combined with some BIOS functionality). Because the HMC provides a serial console via the HMC web interface ("Open console terminal") the serial port is disabled when the system is connected (and recognized) by a HMC. Because the HMC is a separate machine and could go down, be reinstalled, etc., the system remembers that it is connected to one and stays that way even if the HMC is not connected (this is why it did not revert when you unplugged the network).

There are methods to deconfigure a configured HMC on the system (this is for POWER 7, but POWER5 is practically identical). You need to use the "pocket-calculator"-like device hanging ususally out of the system for that. (IIRC waiting also helps, but takes 14 days since the last HMC connection.)

Sometimes in the transition between POWER4 and POWER5 the speed of the console was set from 9600 u,1,p to 19200 u,1,p. Its been a long time since but as far as i remember all the POWER5 and some of the POWER4 were on 19200, the systems before are all using 9600, the systems after that are all 19200.

I hope this helps.

bakunin
These 2 Users Gave Thanks to bakunin For This Post:
 

9 More Discussions You Might Find Interesting

1. AIX

Installing via serial console

I'm stuck - when I boot the machine and hit 5 on the keyboard, all I get is an SP login. Can someone give me some tips on how to get to the install via the serial port? (2 Replies)
Discussion started by: tb0ne
2 Replies

2. HP-UX

serial console hangs

I have a HP Visualize C200 running hpux that I am trying to boot into using a null modem through com1 from my Sun Ultra 10. I get all the way to the login prompt and then it becomes innactive and wont let me access the machine anymore. Any ideas? (2 Replies)
Discussion started by: trajek
2 Replies

3. AIX

Turn off System attention light on POWER5 model p5 55A ?

Hi, Because of previous error System attention light(yellow exclamation mark) is on. How do I turn it off ? thanks Vilius (2 Replies)
Discussion started by: vilius
2 Replies

4. OS X (Apple)

Use a Serial Console with Mac OS X Leopard

I'm trying to use an old Commodore 128D as a terminal to access OS X's shell via a serial port. I've used 'screen' and 'zterm' to ensure the two machines are successfully interfaced. Instructions for opening up the serial console on other Unix-y operating systems don't work with OS X Leopard. ... (3 Replies)
Discussion started by: joecassara
3 Replies

5. UNIX for Dummies Questions & Answers

IP Console Vs Serial console.

Hi Gurus, Can some one explain me the difference between a IP console and a serial console. (1 Reply)
Discussion started by: rama krishna
1 Replies

6. Solaris

V890 serial console inaccessible

I am battling to get a V890 up and running. The system appears to have AUTOBOOT=false, so no OS comes up when it's powered on, and I do not have the credentials to get to the RSC management console. Output to ttya serial console ends at "Probing I/O buses", I assume because output is then being... (4 Replies)
Discussion started by: dstmark
4 Replies

7. Solaris

How to setup a serial console?

i am running solaris 10 in my vmware workstation. How to setup a console for my solaris box. in Vmware i could see a serial port option. can some one help me on how i can setup a console . (0 Replies)
Discussion started by: chidori
0 Replies

8. AIX

How to install AIX 5 on 9133-55a?

hello everyone :D i'm new to AIX and i loved it the moment i saw an AIX admin who came to where i work to install an AIX server for an ERP project, i loved it so much that i bought the old server in my company my server is 9133-55a the server has no graphic card, and i cant use HMC how can... (3 Replies)
Discussion started by: pico
3 Replies

9. Solaris

$ Prompt on Serial console is not responding.

Hi Experts. i have been stuck up with an issue. i have connected my Solaris 8 , Sun fire V445 on serial port by using Teraterm. Initially i was able to login and executed some tasks. After executing some commands (mainly Control +c), i am not able to type any key or not able to do anything at... (2 Replies)
Discussion started by: siddulamadhu
2 Replies
BOOT(8) 						      System Manager's Manual							   BOOT(8)

NAME
boot - connect to the root file server SYNOPSIS
/boot [ -fkm ] [ -uusername ] [ method!fs-addr ] DESCRIPTION
Boot is the first program run after a kernel has been loaded. It connects to the file server that will serve the root, performs any authentication needed to connect to that server, and exec(2)'s the init(8) program. It is started by the kernel, never run directly by the user. See booting(8) for information about the process of loading the kernel (and boot) into memory. Once loaded, the kernel initializes its data structures and devices. It sets the two environment variables /env/cputype and /env/terminal to describe the processor. It then binds a place-holder file server, root(3), onto / and crafts an initial process whose sole function is to exec(2) /boot, a binary which is compiled into root(3). The command line passed depends on the information passed from boot ROM to kernel. On the MIPS Magnum and SGI Power Series the command line passed to boot is the same as that given to the ROM monitor. On AT&T Gnots the command line is /68020/9gnot method!server On the Nextstation , no information is passed from the boot ROM or program. The command line is /68020/9nextstation On the PC, each line in the DOS file plan9.ini of the form name=value is passed to the boot program as an environment variable with the same name and value. The command line is /386/9pc method!server Boot must determine the file server to use and a method with which to connect to it. It must also set a user name to be used as the owner of devices and all console processes and an encryption key to be used when challenged. Boot will prompt for these. Method and address are prompted for first. The prompt lists all valid methods, with the default in brackets. root is from (il, tcp, hs, local)[il]: A newline picks the default. Other possible responses are method or method!address. To aid in automatic reboot, the default is automati- cally taken on CPU servers if nothing is typed within 15 seconds. The other interactions depend on whether the system is a terminal or a CPU server. Terminal The terminal must have a username to set. If none is specified with the -u option, boot will prompt for one on the console: user: The user will also be prompted for a password to be used as an encryption key on each attach(5): password: With most methods boot can now connect to the file server. However, with the serial line methods 9600 and 19200, the actual mechanics of setting up the complete connection are too varied to put into the boot program. Instead boot lets the user set up the connection. It prints a prompt on the console and then simulates a dumb terminal between the user and the serial line: Connect to file system now, type ctrl-d when done. (Use the view or down arrow key to send a break) The user can now type at a modem or a Datakit destination please: interface to set up the connection to a TSM8 card. At Murray Hill, a user would type nj/astro/plan85 at this point. When the user types a control-D, boot stops simulating a terminal and starts the file sys- tem protocol over the serial line. Once connected, boot mounts the root file system before / and makes the connection available as #s/boot for subsequent processes to mount (see bind(2)). Boot completes by exec(2)'ing /$objtype/init -t. If the -m option is given it is also passed as an option to init. If the kernel has been built with the cache file system, cfs(4), the local disk partition /dev/[sh]d[01]cache exists, and the root file system is from a remote server, then the kernel will insert a user level cache process between the remote server and the local namespace that caches all remote accesses on the local partition. The -f flag commands cfs to reformat the cache partition. CPU Servers The user owning devices and console processes on CPU servers and that user's domain and encryption key are read from NVRAM on all machines except PC's. PC's keep the information in the disk partition /dev/[sh]d[01]nvram. If a -k option is given or if no stored information is found boot will prompt for all three items and store them. password: authid: bootes authdom: research.att.com The key is used for mutual authentication of the server and its clients. The domain and id identify the owner of the key. Once connected, boot behaves as on the terminal except for exec(2)'ing /$objtype/init -c. Booting Methods The methods available to any system depend on what was compiled into the kernel. The complete list of booting methods are listed below. cyc connect via a point-to-point fiber link using Cyclone boards. If specified, the address must be the number of the Cyclone board to be used, default 0. il connect via Ethernet using the IL protocol. tcp connect via Ethernet using the TCP protocol. This method is used only if the initial file server is on a Unix system. hs connect via Datakit using the high speed Datakit card. incon connect via Datakit using the Incon interface. 9600 connect via Datakit using the serial interface at 9600 baud. 19200 connect via Datakit using the serial interface at 19200 baud. local connect to the local file system. For the il and tcp methods, the address must be a numeric IP address. If no address is specified, a file server address will be found from another system on the network using the BOOTP protocol and the Plan 9 vendor-specific fields. For the Datakit methods, hs, 9600, 19200, and incon, the address must be specified and must be a relative path name to the file server. If no address is specified, the address Nfs is used. FILES
#s/boot SOURCE
/sys/src/9/boot SEE ALSO
root(3), bootp(8), init(8) BOOT(8)
All times are GMT -4. The time now is 10:40 AM.