01-20-2016
Hi,
Can you run a "poweron" on the server, or is it on a production network?
There may be an issue with the AC supply.
Regards
Gull04
Last edited by gull04; 01-20-2016 at 07:17 AM..
10 More Discussions You Might Find Interesting
1. Solaris
Hi,
I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies
2. Solaris
Hi all
A couple of new M5000 servers will be arriving soon and I need to work out how to configure the underlying domains.
It will come with 4 x CPUS, 32 Gb of memory, 4 x HD, 2 x IOtrays.
Reading the XSCF manual, I can configure the item into 2 domains, something about uni / quad xsb.... (9 Replies)
Discussion started by: sbk1972
9 Replies
3. Solaris
Hi i 've a M5000 running 2 domains in my Lab with following hardconf
SPARC Enterprise M5000; Memory_Size:128 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies
4. Solaris
Please advise. Thank you
bash-3.00# cd /usr/sunvts/bin/
bash-3.00# ls
bios.bin iobushangscript.sh stopsunvts vtsprobe
cmos.bin javabridge.jar sunlink vtsreportgenerate
dispatcher loadVtsServer svmVolDiskList vtstalk
env6test... (6 Replies)
Discussion started by: incredible
6 Replies
5. HP-UX
Hello,
I am installing RX7640 and i have some issue with the memory modules. My system shows them as deconfigured.
Do you think I use the right memories? (2 Replies)
Discussion started by: stapley
2 Replies
6. Solaris
Trying to update my M5000 firmware. trying to mount my USB to upload firmware and getting the following message.
XSCF> getflashimage -v file:///media/usb_msd/FFXCP1115.tar.gz
Free space: 97MB
Making sure mount point is clear
umount: /media/usb_msd is not mounted (according to mtab)
Trying... (2 Replies)
Discussion started by: soupbone38
2 Replies
7. Solaris
Hi Community,
i have one M5000 spare machine which was handled by support team. they told me that it is gone completely .
i have checked the status. before it was showing MBU_B degraded. i updated to latest firmware and , resetted the xscf and now this is showing as normal.
MBU_B... (5 Replies)
Discussion started by: bentech4u
5 Replies
8. IP Networking
I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip.
it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out.
so my question is,
any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies
9. Solaris
I have an m5000 that Is down.
I have access to XSCF>
and was able to get to the ok prompt.
However, on
>ok boot
it failed to boot.
erred with :
svc.startd: svc:/system/device/fc-fabric:default: Method "/lib/svc/method/fc-fabric" failed due to signal KILL.
Nov 29... (3 Replies)
Discussion started by: goya
3 Replies
10. Hardware
on an m5000 , I can not power it up, system failure.
XSCF> poweron -a
DomainIDs to power on:00,01
Continue? :y
00 :Not powering on :Poweron canceled due to missing component.
01 :Not powering on :Poweron canceled due to missing component.
the only fault that I can see is:
... (4 Replies)
Discussion started by: goya
4 Replies
LEARN ABOUT ULTRIX
bindsetup
bindsetup(8) System Manager's Manual bindsetup(8)
Name
bindsetup - set up the Berkeley Internet Name Domain (BIND)/Hesiod service
Syntax
/usr/etc/bindsetup [ -c [ -d directory ] -b binddomain name1,IP1 name2,IP2 ... ]
Description
The command sets up the Berkeley Internet Name Domain (BIND)/Hesiod service on your system and places and resolution under BIND/Hesiod con-
trol. You can use this command to set up your system as a primary, secondary, slave, or caching server, or as a client.
In order to run BIND/Hesiod, your system's host name must include the BIND domain name. The BIND host name consists of the local host name
plus the BIND domain name, separated by periods. For example, the BIND host name for a system whose local host name is and whose BIND
domain name is is
The command edits the and files and changes the local host name to the BIND host name, if it is not there already.
If the command changes your system's host name, you should reboot the system to be sure that the change is propagated throughout the sys-
tem.
Before you run , your system must be established on a local area network. In addition, you must know the BIND domain name for your local
area network, and whether your system will be a primary, secondary, slave, or caching server, or a client.
The command asks if you want to run a Kerberos authentication server. You must already have set up Kerberos to do do. For more informa-
tion, see the Guide to Kerberos.
You should run the command as superuser and with the system in multiuser mode.
If you use the option with the respective arguments, the command sets up your system as a BIND/Hesiod client non-interactively.
If you run the command with no arguments, a menu is displayed giving you a choice of responses. You are then prompted for further informa-
tion. Before exits, it lists the files that have been updated.
Once BIND/Hesiod is installed on a machine, it cannot be used until the file is modified to contain BIND entries on the desired database
lines. The command reminds a user to run or edit the file manually.
Options
-c Sets up your system as a BIND/Hesiod client according to the following arguments you supply on the command line:
-d directory
This option and argument are required if you are setting up a diskless client from the diskless server. The directory is the
full path name of the root directory for your system (a diskless client) on the diskless server. The following is an example
of a root directory for a diskless client named
/dlclient0/orange.root
-b binddomain
This is the name of the BIND domain on which your system will be a BIND client. For example, is a sample BIND domain name.
name,IP This is the host name and the IP address of the BIND server on the domain, for example You can specify one or more BIND server
by listing more name,IP arguments, each separated by a space.
Files
List of locally maintained host names and IP addresses
Startup commands pertinent to a specific system
Database name with the selected naming services
Hesiod configuration file
List of Kerberos servers
Default BIND Files:
BIND server data file directory
BIND server boot file
BIND server cache file
BIND server local host reverse address host file
BIND primary server hosts file
BIND primary server reverse address hosts file
BIND data file
See Also
nslookup(1), hesiod(3), hesiod.conf(5), svc.conf(5), svcsetup(8), named(8), krb.conf(5), resolv.conf(5)
Guide to the BIND/Hesiod Service
Guide to Kerberos
bindsetup(8)