Sponsored Content
Full Discussion: Reboot VIO - OK?
Operating Systems AIX Reboot VIO - OK? Post 302964478 by DiViN3 on Friday 15th of January 2016 01:55:25 AM
Old 01-15-2016
IBM Reboot VIO - OK?

We've got two datacenters and in every datacenter 2 VIOs.
The VIO manages the I/O of the LPARs. So: Is it possible to reboot the VIO without shuting down an LPARSmilie
 

10 More Discussions You Might Find Interesting

1. Solaris

different between soft reboot and hard reboot

Hi Guru's Can any want here could explain to me the different between soft reboot and hard reboot . Best Regards Seelan (3 Replies)
Discussion started by: seelan3
3 Replies

2. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

3. AIX

vio related

In a dual vio, how will u know one lpar is in which vio? (1 Reply)
Discussion started by: shobhan.murthy
1 Replies

4. AIX

VIO Redundancy

Hi Guys, I'm working on building a new 595 machine.. I'm try to achieve high availability for the VIO clients using 2 VIO servers, The ethernet part is satisfied using SEA failover, Now how do I achieve redundancy for the disks, its the servers internal disk attached to the scsi cards... ... (2 Replies)
Discussion started by: kkeng808
2 Replies

5. AIX

Vio Build

I am planning carving out dual VIO servers on a P750 based and would like to know how to allocate internal disks to the VIOS. This has 4 internal disks and I would to assign 2 disks to each VIO. This is what I was thinking of assigning . Any advise? vio1 U5802.001.9K8H757-P1-C1 PCI-E x8... (17 Replies)
Discussion started by: mk8570
17 Replies

6. AIX

sddpcm on vio

I have same lun (hdisk3) assigned to 2 vios server (dual vio server) and this is mapped to the client lpar. I have sddpcm on the VIO. On the VIOA, the attributes for fscsi1 and fscsi3 are set to fast_fail and dyntrk is set to yes Now, if I do a lqueryvg -Atp on the hdisk3, I get a "DISK... (4 Replies)
Discussion started by: mk8570
4 Replies

7. Red Hat

vio in linux

I am working in AIX. In a P series machine both aix and linux os can install.. specific command is there for aix to list out the vio servers details mapped in a frame(ie. lssrc "IBM.ManagementServer", like that..) is there any command is der to list out vio servers details in linux or how to find... (1 Reply)
Discussion started by: muralikrish
1 Replies

8. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

9. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies

10. AIX

Problems with VIO O/S 2.2.3

I hope someone has experienced this problem before and can help. I have a P730 (8231-E2D) which is fitted with 8 IBM SAS disks on 2 separate SISSAS controllers. The disk type is ST9146853SS (Seagate SAS 146Gb). The problem occurs when I try to install the VIO server software at 2.2.3. It... (3 Replies)
Discussion started by: johnf
3 Replies
SHUTDOWN(8)							     shutdown							       SHUTDOWN(8)

NAME
shutdown - Halt, power-off or reboot the machine SYNOPSIS
shutdown [OPTIONS...] [TIME] [WALL...] DESCRIPTION
shutdown may be used to halt, power-off or reboot the machine. The first argument may be a time string (which is usually "now"). Optionally, this may be followed by a wall message to be sent to all logged-in users before going down. The time string may either be in the format "hh:mm" for hour/minutes specifying the time to execute the shutdown at, specified in 24h clock format. Alternatively it may be in the syntax "+m" referring to the specified number of minutes m from now. "now" is an alias for "+0", i.e. for triggering an immediate shutdown. If no time argument is specified, "+1" is implied. Note that to specify a wall message you must specify a time argument, too. If the time argument is used, 5 minutes before the system goes down the /run/nologin file is created to ensure that further logins shall not be allowed. OPTIONS
The following options are understood: --help Prints a short help text and exits. -H, --halt Halt the machine. -P, --poweroff Power-off the machine (the default). -r, --reboot Reboot the machine. -h Equivalent to --poweroff, unless --halt is specified. -k Do not halt, power-off, reboot, just write wall message. --no-wall Do not send wall message before halt, power-off, reboot. -c Cancel a pending shutdown. This may be used cancel the effect of an invocation of shutdown with a time argument that is not "+0" or "now". EXIT STATUS
On success, 0 is returned, a non-zero failure code otherwise. SEE ALSO
systemd(1), systemctl(1), halt(8), wall(1) systemd 208 SHUTDOWN(8)
All times are GMT -4. The time now is 01:40 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy