01-04-2016
Thanks Robin .
So it will be using same physical card . Except that physical card will be part of the VIO server , I will be creating SEA using the Physical card. Currently the 710 has only one physical LPAR using all system resources and network is configured just like any other physical LPAR. My plan is to :
1) delete that LPAR
2) put the VIO code (COD ) , so it will have option to create VIO server
3) create VIO server
4) create SEA using physical NIC , so the future VIO client can used the same network
----
So for the item 4, question is what need to be changed from the network side, like I said 710 is currently connected to network , But for SEA , obviously we need to add VLAN and stuff, so all the client lpar can connect to network using same VLAN. What is the networking requirement for that ? Thanks again.
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hello,
I need explanations about physical disks and physical volumes. What is the difference between these 2 things?
In fact, i am trying to understand what the AIX lspv2command does.
Thank you in advance. (2 Replies)
Discussion started by: VeroL
2 Replies
2. UNIX for Dummies Questions & Answers
I was in smit, checking on disc space, etc. and it appears that one of our physical volumes that is part of a large volume group, has no free physical partitions. The server is running AIX 5.1. What would be the advisable step to take in this instance? (9 Replies)
Discussion started by: markper
9 Replies
3. HP-UX
Hi,
I have two questions here.
I need to find out the number of physical processors the HP-UX operating system is running in. Here i am referring to the physical processors in a system and not the number of cores.
I can get the number of cores using the command 'ioscan -fnkC processor'.... (7 Replies)
Discussion started by: shawshank
7 Replies
4. AIX
Hello All,
Can anybody please tell me what is the maximum limit of Physical IBM Power Machine which can be handled by single HMC at a single point of time?
Thanks,
Jenish (1 Reply)
Discussion started by: jenish_shah
1 Replies
5. UNIX for Advanced & Expert Users
Hey all,
We have an old Data General Unix system (DG/UX) on an old AViiON machine.
That DG system is Intel-based (PentiumPro) and we are trying to virtualize / emulate it.
DG was a clever system, as it cannot be installed on a 'regular' x86 machine, only on an AViiON box. I think I figured out... (2 Replies)
Discussion started by: dgux
2 Replies
6. UNIX for Advanced & Expert Users
same old story, we have an important very old app running on SCO 5, box is only on LAN and as such was never updated by anyone etc.. box is nearing its end of life in a bad way (currently experiencing some SCSI issues) and it's time to do something when good advice of "lets upgrade" for years was... (1 Reply)
Discussion started by: mc18
1 Replies
7. Solaris
hi,
I am using command psrinfo -p to check the number of physical processors present on any soalris machine.I want to check the number of virtual processors assigned for particular solaris machine.
which command/set of command need to be used which can grep or show the total virtual processors... (8 Replies)
Discussion started by: omkar.jadhav
8 Replies
8. UNIX for Beginners Questions & Answers
I have a physical machine , just use vmware tools migrated data to virtual machine .
how can I check these two servers - old and new server , the data are the same , all files are copy to new server ?
thanks (2 Replies)
Discussion started by: ust3
2 Replies
9. UNIX for Beginners Questions & Answers
Hi All,
.
I am trying to find whether Solaris 11 installed on physical server or on VMware/KVM.
I tried uname -a but it's giving only whether i installed on X86 or sparc machine.
I tried prtdiag command but it's giving below information.
command : prtdiag -v |grep "System... (2 Replies)
Discussion started by: sravani25
2 Replies
LEARN ABOUT DEBIAN
fence_apc
FENCE_AGENT(8) System Manager's Manual FENCE_AGENT(8)
NAME
fence_apc - Fence agent for APC over telnet/ssh
DESCRIPTION
fence_apc is an I/O Fencing agent which can be used with the APC network power switch. It logs into device via telnet/ssh and reboots a
specified outlet. Lengthy telnet/ssh connections should be avoided while a GFS cluster is running because the connection will block
any necessary fencing actions.
fence_apc accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent.
fence_apc can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts.
Vendor URL: http://www.apc.com
PARAMETERS
-o, --action=<action>
Fencing Action (Default Value: reboot)
-a, --ip=<ip>
IP Address or Hostname This parameter is always required.
-l, --username=<name>
Login Name This parameter is always required.
-p, --password=<password>
Login password or passphrase
-S, --password-script=<script>
Script to retrieve password
-x, --ssh
SSH connection
-n, --plug=<id>
Physical plug number or name of virtual machine This parameter is always required.
-k, --identity-file=<filename>
Identity file for ssh
-s, --switch=<id>
Physical switch number on device
-4, --inet4-only
Forces agent to use IPv4 addresses only
-6, --inet6-only
Forces agent to use IPv6 addresses only
-u, --ipport=<port>
TCP port to use for connection with device
-v, --verbose
Verbose mode
-D, --debug-file=<debugfile>
Write debug information to given file
-V, --version
Display version information and exit
-h, --help
Display help and exit
-C, --separator=<char>
Separator for CSV created by operation list (Default Value: ,)
--power-timeout
Test X seconds for status change after ON/OFF (Default Value: 20)
--shell-timeout
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
--login-timeout
Wait X seconds for cmd prompt after login (Default Value: 5)
--power-wait
Wait X seconds after issuing ON/OFF (Default Value: 0)
--delay
Wait X seconds before fencing is started (Default Value: 0)
--retry-on
Count of attempts to retry power on (Default Value: 1)
ACTIONS
on Power on machine.
off Power off machine.
reboot Reboot machine.
status This returns the status of the plug/virtual machine.
list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise.
monitor
Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more).
metadata
The operational behavior of this is not known.
STDIN PARAMETERS
action Fencing Action (Default Value: reboot)
ipaddr IP Address or Hostname This parameter is always required.
login Login Name This parameter is always required.
passwd Login password or passphrase
passwd_script
Script to retrieve password
secure SSH connection
port Physical plug number or name of virtual machine This parameter is always required.
identity_file
Identity file for ssh
switch Physical switch number on device
inet4_only
Forces agent to use IPv4 addresses only
inet6_only
Forces agent to use IPv6 addresses only
ipport TCP port to use for connection with device
verbose
Verbose mode
debug Write debug information to given file
version
Display version information and exit
help Display help and exit
separator
Separator for CSV created by operation list (Default Value: ,)
power_timeout
Test X seconds for status change after ON/OFF (Default Value: 20)
shell_timeout
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
login_timeout
Wait X seconds for cmd prompt after login (Default Value: 5)
power_wait
Wait X seconds after issuing ON/OFF (Default Value: 0)
delay Wait X seconds before fencing is started (Default Value: 0)
retry_on
Count of attempts to retry power on (Default Value: 1)
fence_apc (Fence Agent) 2009-10-20 FENCE_AGENT(8)