Hello folks,

I have Hp.ux 11.31 and I need know how formating in OS new LUN disk attach to system

e.g. the wwid:

Code:
# scsimgr lun_map -D /dev/rdisk/disk4

        LUN PATH INFORMATION FOR LUN : /dev/rdisk/disk4

Total number of LUN paths     = 2
World Wide Identifier(WWID)    = 0x60060e80056541000000654100000000

LUN path : lunpath8
Class                         = lunpath
Instance                      = 8
Hardware path                 = 0/3/0/0/0/0.0x50060e8005654100.0x4003000000000000
SCSI transport protocol       = fibre_channel
State                         = ACTIVE
Last Open or Close state      = ACTIVE

LUN path : lunpath7
Class                         = lunpath
Instance                      = 7
Hardware path                 = 0/3/0/0/0/1.0x50060e8005654110.0x4003000000000000
SCSI transport protocol       = fibre_channel
State                         = ACTIVE
Last Open or Close state      = ACTIVE

like format this LUN 0x60060e80056541000000654100000000 for erase all information,

and later create traditional file system,

thanks you,

Last edited by vbe; 09-08-2015 at 04:51 PM.. Reason: code tags not icode please
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Disk formating

i have to repartition some of my filesystems ... I have just one HDD .... df -k gives this :- Filesystem kbytes used avail capacity Mounted on /dev/dsk/c0t0d0s0 830107 45532 726468 6% / /dev/dsk/c0t0d0s1 1987399 785728 1142050 41% /usr /proc ... (1 Reply)
Discussion started by: DPAI
1 Replies

2. UNIX for Advanced & Expert Users

VxVM disk/lun grow

hi, i have a volume on a LUN of an EMC-storage and i need to increase the size. i could increase the size of the LUN on the EMC, i could increase the size of the disk for solaris, but how can i tell the veritas volume manager that the disk is larger now? what i've done: 1. LUN on EMC 2.... (3 Replies)
Discussion started by: pressy
3 Replies

3. Solaris

command to scan Enterprise storage Lun disk in Solaris

I just installed IBMsdd on Solaris diver along with the patches recommended. I also installed 2 - 2Gigs qlogic fiber cards & the corresponding pkges for the cards. What command can I use to scan this LUN disks from my Soalris servers. Solaris doen't seem to be seeing this disks presented on it.... (2 Replies)
Discussion started by: Remi
2 Replies

4. AIX

Problem mapping LUN disk from VIOS to the LPAR

Hello guys, It would be so nice of you if someone can provide me with these informations. 1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
Discussion started by: solaix14
3 Replies

5. Solaris

I have LUN ID, how to find disk relate to that LUN ID?

I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer. thanks (4 Replies)
Discussion started by: uuontario
4 Replies

6. Shell Programming and Scripting

Formating output

Hello Team i have a file with following data (as columns). I need implement a syntax like below for altering table ALTER TABLE1 TABLENAME ADD COLUMN COL1 CHAR(5) NOT NULL WITH DEFAULT ADD COLUMN COL2 CHAR(5) .. .. ADD COLUMN COLn CHAR(5) NOT NULL... (1 Reply)
Discussion started by: rocking77
1 Replies

7. HP-UX

Disk file and Lun Number

HI all, I am confused when I am seeing the output of bdf command ioscan -fnC disk, there is no same files which i have seen in bdf output and ioscan output...One volume was mounted in one folder called /teldb and device file path was /dev/disk/disk48. The same i didnt found in ioscan disk... (6 Replies)
Discussion started by: selvaforum
6 Replies

8. UNIX for Dummies Questions & Answers

Help with formating when using mailx

Hi I am a newbie here. I tried searching for the solution but I guess I either didn't find it or there hasn't been one posted. my problem is I spooled the results of a query into a .txt file. When I cat the file the formating looks great. All the columns are aligned. However once I mailx the... (2 Replies)
Discussion started by: RB26DETT
2 Replies

9. UNIX for Dummies Questions & Answers

Which disk is LUN?

how do I know which hdisk from "lsdev -Cc disk" is my LUN on NetApp after zoning from SAN switch? is it "MPIO other FC SCSI Disk Drive"? (1 Reply)
Discussion started by: malayo
1 Replies

10. UNIX for Beginners Questions & Answers

File formating help

Hi all, I am having the file below I need that as below Thanks, Arun (12 Replies)
Discussion started by: arunkumar_mca
12 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR