Old 07-28-2015
I don't know the name of your managed system. It is the IBM server, where all your LPARs reside. You can look which managed systems you have using the command lssyscfg -r sys -F name
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

TIME_WAIT state

in TCP, is TIME_WAIT state really essential..!!! (3 Replies)
Discussion started by: sasikanth
3 Replies

2. Solaris

Zone in down state.

One of my zone is stuck in down state, not able to boot it or halt it .. not even detach .. is there any way to recover without rebooting the whole system ( global zone ) ? (3 Replies)
Discussion started by: fugitive
3 Replies

3. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

4. AIX

Vscsi and npiv on same adapter

Hi, I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers? Thanks, Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies

5. AIX

hdisk mapping to a vSCSi Adapter

Hello, I have a VIOS System and would like to do mapping some hdisks, hdisk160 until hdisk165 to a vSCSi Adapter. I try to do this in the oem_setup_env like the following: for i in $(lspv | grep hdisk* | awk {'print $1'}; do mkdev -V $i -p vhost20 done There where a mapping with... (4 Replies)
Discussion started by: torsten163
4 Replies

6. AIX

Kdb - vscsi disk mapping from AIX 5.3 CLIENT side

If you're familiar with vscsi mappings thru a VIO Server, you are probably aware, on an AIX 6.1 Client LPAR, that: print cvai | kdbcan provide useful information to you.... like VIO Server name & vhost #. But, "cvai" does not appear to be part of the Kernel Debugger in AIX 5.3. My question is... (3 Replies)
Discussion started by: The Doctor
3 Replies

7. AIX

Open firmware state to running state

Hi Admins, I am having a whole system lpar in open firmware state on HMC. How can I bring it to running state ? Let me know. Thanks. (2 Replies)
Discussion started by: snchaudhari2
2 Replies

8. AIX

Devices.vscsi.disk ?

Hello, When I assigned CDROM from IVM (VIOS) to LPAR and then running cfgmgr i get the following message on the client lpar #cfgmgr cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.vscsi.disk searching... (0 Replies)
Discussion started by: filosophizer
0 Replies

9. UNIX for Advanced & Expert Users

Unable to install client AIX LPAR to vscsi hdisk provided from VIOS

Hi everybody, I have Power5 server with 4 internal hdisks each of 70Gb. VIOS server was installed via Virtual I/O Server Image Repository on the HMC. HMC release - 7.7.0 VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Discussion started by: Ravil Khalilov
2 Replies
Managed Object(3m17n)						 The m17n Library					     Managed Object(3m17n)

NAME
Managed_Object - Objects managed by the reference count. Data Structures struct M17NObjectHead The first member of a managed object. Functions void * m17n_object (int size, void(*freer)(void *)) Allocate a managed object. int m17n_object_ref (void *object) Increment the reference count of a managed object. int m17n_object_unref (void *object) Decrement the reference count of a managed object. Detailed Description Objects managed by the reference count. Managed objects are objects managed by the reference count. There are some types of m17n objects that are managed by their reference count. Those objects are called managed objects. When created, the reference count of a managed object is initialized to one. The m17n_object_ref() function increments the reference count of a managed object by one, and the m17n_object_unref() function decrements by one. A managed object is automatically freed when its reference count becomes zero. A property whose key is a managing key can have only a managed object as its value. Some functions, for instance msymbol_put() and mplist_put(), pay special attention to such a property. In addition to the predefined managed object types, users can define their own managed object types. See the documentation of the m17n_object() for more details. Author Generated automatically by Doxygen for The m17n Library from the source code. Data Structure Documentation M17NObjectHead FIELD DOCUMENTATION: void* M17NObjectHead::filler[2] COPYRIGHT
Copyright (C) 2001 Information-technology Promotion Agency (IPA) Copyright (C) 2001-2011 National Institute of Advanced Industrial Science and Technology (AIST) Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License <http://www.gnu.org/licenses/fdl.html>. Version 1.6.2 12 Jan 2011 Managed Object(3m17n)
All times are GMT -4. The time now is 08:17 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy