07-28-2015
I don't know the name of your managed system. It is the IBM server, where all your LPARs reside. You can look which managed systems you have using the command lssyscfg -r sys -F name
9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
in TCP, is TIME_WAIT state really essential..!!! (3 Replies)
Discussion started by: sasikanth
3 Replies
2. Solaris
One of my zone is stuck in down state, not able to boot it or halt it .. not even detach .. is there any way to recover without rebooting the whole system ( global zone ) ? (3 Replies)
Discussion started by: fugitive
3 Replies
3. AIX
Hi All,
I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV.
My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies
4. AIX
Hi,
I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers?
Thanks,
Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies
5. AIX
Hello,
I have a VIOS System and would like to do mapping some hdisks, hdisk160 until hdisk165 to a vSCSi Adapter. I try to do this in the oem_setup_env like the following:
for i in $(lspv | grep hdisk* | awk {'print $1'};
do
mkdev -V $i -p vhost20
done
There where a mapping with... (4 Replies)
Discussion started by: torsten163
4 Replies
6. AIX
If you're familiar with vscsi mappings thru a VIO Server, you are probably aware, on an AIX 6.1 Client LPAR, that:
print cvai | kdbcan provide useful information to you.... like VIO Server name & vhost #. But, "cvai" does not appear to be part of the Kernel Debugger in AIX 5.3.
My question is... (3 Replies)
Discussion started by: The Doctor
3 Replies
7. AIX
Hi Admins,
I am having a whole system lpar in open firmware state on HMC.
How can I bring it to running state ?
Let me know. Thanks. (2 Replies)
Discussion started by: snchaudhari2
2 Replies
8. AIX
Hello,
When I assigned CDROM from IVM (VIOS) to LPAR and then running cfgmgr i get the following message on the client lpar
#cfgmgr
cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed.
devices.vscsi.disk
searching... (0 Replies)
Discussion started by: filosophizer
0 Replies
9. UNIX for Advanced & Expert Users
Hi everybody,
I have Power5 server with 4 internal hdisks each of 70Gb.
VIOS server was installed via Virtual I/O Server Image Repository on the HMC.
HMC release - 7.7.0
VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Discussion started by: Ravil Khalilov
2 Replies
LEARN ABOUT DEBIAN
m17nobject
Managed Object(3m17n) The m17n Library Managed Object(3m17n)
NAME
Managed_Object - Objects managed by the reference count.
Data Structures
struct M17NObjectHead
The first member of a managed object.
Functions
void * m17n_object (int size, void(*freer)(void *))
Allocate a managed object.
int m17n_object_ref (void *object)
Increment the reference count of a managed object.
int m17n_object_unref (void *object)
Decrement the reference count of a managed object.
Detailed Description
Objects managed by the reference count.
Managed objects are objects managed by the reference count.
There are some types of m17n objects that are managed by their reference count. Those objects are called managed objects. When created, the
reference count of a managed object is initialized to one. The m17n_object_ref() function increments the reference count of a managed
object by one, and the m17n_object_unref() function decrements by one. A managed object is automatically freed when its reference count
becomes zero.
A property whose key is a managing key can have only a managed object as its value. Some functions, for instance msymbol_put() and
mplist_put(), pay special attention to such a property.
In addition to the predefined managed object types, users can define their own managed object types. See the documentation of the
m17n_object() for more details.
Author
Generated automatically by Doxygen for The m17n Library from the source code.
Data Structure Documentation
M17NObjectHead
FIELD DOCUMENTATION:
void* M17NObjectHead::filler[2]
COPYRIGHT
Copyright (C) 2001 Information-technology Promotion Agency (IPA)
Copyright (C) 2001-2011 National Institute of Advanced Industrial Science and Technology (AIST)
Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License
<http://www.gnu.org/licenses/fdl.html>.
Version 1.6.2 12 Jan 2011 Managed Object(3m17n)