07-28-2015
Quote:
Originally Posted by
agent.kgb
What happens if you execute mkdev -l vscsi1?
Do I have to make vscsi1? it looks as if its already made. no?
also should I try these commands in LPAR or vio servers?
9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
in TCP, is TIME_WAIT state really essential..!!! (3 Replies)
Discussion started by: sasikanth
3 Replies
2. Solaris
One of my zone is stuck in down state, not able to boot it or halt it .. not even detach .. is there any way to recover without rebooting the whole system ( global zone ) ? (3 Replies)
Discussion started by: fugitive
3 Replies
3. AIX
Hi All,
I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV.
My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies
4. AIX
Hi,
I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers?
Thanks,
Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies
5. AIX
Hello,
I have a VIOS System and would like to do mapping some hdisks, hdisk160 until hdisk165 to a vSCSi Adapter. I try to do this in the oem_setup_env like the following:
for i in $(lspv | grep hdisk* | awk {'print $1'};
do
mkdev -V $i -p vhost20
done
There where a mapping with... (4 Replies)
Discussion started by: torsten163
4 Replies
6. AIX
If you're familiar with vscsi mappings thru a VIO Server, you are probably aware, on an AIX 6.1 Client LPAR, that:
print cvai | kdbcan provide useful information to you.... like VIO Server name & vhost #. But, "cvai" does not appear to be part of the Kernel Debugger in AIX 5.3.
My question is... (3 Replies)
Discussion started by: The Doctor
3 Replies
7. AIX
Hi Admins,
I am having a whole system lpar in open firmware state on HMC.
How can I bring it to running state ?
Let me know. Thanks. (2 Replies)
Discussion started by: snchaudhari2
2 Replies
8. AIX
Hello,
When I assigned CDROM from IVM (VIOS) to LPAR and then running cfgmgr i get the following message on the client lpar
#cfgmgr
cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed.
devices.vscsi.disk
searching... (0 Replies)
Discussion started by: filosophizer
0 Replies
9. UNIX for Advanced & Expert Users
Hi everybody,
I have Power5 server with 4 internal hdisks each of 70Gb.
VIOS server was installed via Virtual I/O Server Image Repository on the HMC.
HMC release - 7.7.0
VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Discussion started by: Ravil Khalilov
2 Replies