Hi,
I am working on HP-UX Release 11i.
I want to find the process id (PID) of the process running on a particular port.
lsof command fuser does not work on this system.
Please suggest some alternative.
Thanks (6 Replies)
I have one 4GB, dual port HBA. Is each port rated for 4GB, or is it the whole HBA rated for 4GB?
Also, how do I determine which is port0 / port1 with "lscfg -vl fcs0" command. Thanks. (0 Replies)
Unix gurus,
I have a requirement wherein I want to find the port number for a given process id.
Is it possible? If so how?
TIA,
Regards,
Praveen (3 Replies)
Hi,
i have a two port hba card in solaris 10 system one of which is disabled. How to enable and configure the other port.
---------- Post updated at 08:17 AM ---------- Previous update was at 03:40 AM ----------
please help :( (7 Replies)
Hi Everyone,
In my environment, I have few T5220. On the iLOM Management Card, I have both Network and Serial port are cabled, I don't have any issues while I try to connect using Network Management port, but when I try to connect the serial port for the same server which is actually connected... (3 Replies)
Hello,
I have an unloaded T5140 machine and want to access the ILOM for the first time and subsequently the network port after that., and then load Solaris 10 the final January 2011 build.
The first part is what confuses me -the cabling.
I am coming from a Windows machine (w/appropriate... (5 Replies)
hi,
i would like to create a bash script that check which port in my Linux server are closed (not in use) from a specific range, port range (3000-3010).
the print output need to be only 1 port, and it will be nice if the output will be saved as a variable or in same file.
my code is:
... (2 Replies)
Discussion started by: yossi
2 Replies
LEARN ABOUT DEBIAN
irsend
IRSEND(1) User Commands IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.9.0-pre1 October 2010 IRSEND(1)