Sponsored Content
Operating Systems Linux CentOS 6.6 SSD trim on HP DL380 G2 RAID 0 Post 302949530 by cjcox on Sunday 12th of July 2015 08:22:00 PM
Old 07-12-2015
When I saw your subject line I thought.... I don't think so bub... :-) (G2 instead of G6)
 

8 More Discussions You Might Find Interesting

1. Debian

Problem installing debian 4.0 on hp dl380 G5

ello all.. I really have a big problem installing debian 4.0 on HP dl380 G5 ,2 74 sScsi in raid 1 (mirror), after all selected options, it's freezes on getting files 125 of 125 and stops on 5% of the installation. I've try with different cd's and cd-roms so that's not the problem! Can someone... (4 Replies)
Discussion started by: res5it
4 Replies

2. Solaris

HP DL380 G3 vs Solaris 10

1) Does anyone know IF HP Proliant DL380 G3 is compatible to install Solaris 10 - as whenever I tried to install, it gives an error saying 'No disk found' after keying in date/time etc. 2) I found somewhere that text installation will be able to fix it - What is text installation? Thank you (7 Replies)
Discussion started by: panchpan
7 Replies

3. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

4. Red Hat

How to install centos 5.5 using Raid In Virtualbox

Im have Oracle Virtualbox and vmware workstation How can i Add2 HDD in Vmware or Virtualbox and Install centos Using Raid Configuration Please give me Tutorial step by Step .. Thanks in Advance In Virtualbox there is SAS Hard disk So shall i Use it ? (3 Replies)
Discussion started by: babinlonston
3 Replies

5. Filesystems, Disks and Memory

RAID 0 for SSD

Nowadays the fastest SSDs achieve read-speeds of between 1500 MB/s to 1900 MB/s. Let's say that two such SSDs in RAID 0 achieve roughly double the throughput, ie 3000 MB/s. That is only half an order of magnitude removed from RAM ((10)^(1/2) * 3000 = 10.000), very broadly speaking. So for the... (6 Replies)
Discussion started by: figaro
6 Replies

6. Red Hat

HP DL380 g6 Riser kit

I have 2 DL380g6 servers, one server has a riser kit installed and the other does not. running rhel5.6, how from the OS can I see the riser kit is installed? lspci didn't list the riser kit, but then again I'm not entirely sure its classified as a pci device? Is there a way to see it from the OS (1 Reply)
Discussion started by: mkeyes001
1 Replies

7. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

8. Linux

Centos 7.2 Convert single LVM to RAID Mirror Reinstall BootLoader

Hello, I am trying to convert a single-drive Centos 7.2 installation with LVM into a two-disk mdadm mirror with mrrored LVM. I was able to follow the excellent instructions at: http://www.dgoradia.com/creating-a-raid1-mirrored-on-an-existing-centos-on-lvm/and did create a two-disk mirror... (1 Reply)
Discussion started by: Clovis_Sangrail
1 Replies
ARCMSR(4)						   BSD Kernel Interfaces Manual 						 ARCMSR(4)

NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller SYNOPSIS
arcmsr* at pci? dev ? function ? DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation: - ARC-1110 PCI-X 4 Port SATA RAID Controller - ARC-1110ML PCI-X 4 Port SATA RAID Controller - ARC-1120 PCI-X 8 Port SATA RAID Controller - ARC-1120ML PCI-X 8 Port SATA RAID Controller - ARC-1130 PCI-X 12 Port SATA RAID Controller - ARC-1130ML PCI-X 12 Port SATA RAID Controller - ARC-1160 PCI-X 16 Port SATA RAID Controller - ARC-1160ML PCI-X 16 Port SATA RAID Controller - ARC-1170 PCI-X 24 Port SATA RAID Controller - ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller - ARC-1202 PCI Express 2 Port SATA RAID Controller - ARC-1210 PCI Express 4 Port SATA RAID Controller - ARC-1220 PCI Express 8 Port SATA RAID Controller - ARC-1230 PCI Express 12 Port SATA RAID Controller - ARC-1230ML PCI Express 12 Port SATA RAID Controller - ARC-1231ML PCI Express 12 Port SATA RAID Controller - ARC-1260 PCI Express 16 Port SATA RAID Controller - ARC-1260ML PCI Express 16 Port SATA RAID Controller - ARC-1261ML PCI Express 16 Port SATA RAID Controller - ARC-1280 PCI Express 24 Port SATA RAID Controller - ARC-1280ML PCI Express 24 Port SATA RAID Controller - ARC-1680 PCI Express 8 Port SAS RAID Controller - ARC-1680LP PCI Express 8 Port SAS RAID Controller - ARC-1680i PCI Express 8 Port SAS RAID Controller - ARC-1680x PCI Express 8 Port SAS RAID Controller - ARC-1681 PCI-X 8 Port SAS RAID Controller These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives. arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands. Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8). When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol- lowing command (once the initialization is finished): $ scsictl scsibus0 scan any any The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the bioctl(8) command. EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens. SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8) HISTORY
The arcmsr driver first appeared in NetBSD 5.0. AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines. BSD
March 3, 2008 BSD
All times are GMT -4. The time now is 01:03 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy