Operating Systems AIX VSwitch not showing up on VIO Server Post 302940722 by juredd1 on Wednesday 8th of April 2015 01:15:11 PM
Old 04-08-2015
VSwitch not showing up on VIO Server

Want to run this by you all before opening a PMR with IBM Support.

It's been a few weeks since I have done this so I can't be 100% sure of how I think it worked in the previous version.

We upgraded our HMC's yesterday to 7.7.9 SP2 in hopes of fixing some issues we were having. Today I needed to add a couple virtual network adapters. I first added to the profile and I am unable to select the VSwitch other than Ethernet0 (default) and I am unable to add VLAN's after selecting IEEE tab. If I select the IEEE tab and select OK and then go back to edit that new adapter I can then add the VLAN's I need on that adapter. However I am not able to still select the VSwitch that I am needing to use.

I also tried to do this via DLPAR but I am unable to select anything but the ETHERNET0 VSwitch which does not exist as we replaced it with our own name so the DLPAR function fails.

Ideas appreciated.

Thanks,
Justin
 

10 More Discussions You Might Find Interesting

1. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

2. AIX

how to erase VIO server's rootvg?

how to erase VIO server's rootvg? I don't have CD can reinstall a new OS, can I go to maintenance to erase rootvg? (1 Reply)
Discussion started by: rainbow_bean
1 Replies

3. AIX

Identifying the vio server names

Hi My vio client is getting its virtual Ethernet services from dual vio servers. What command if I execute on the vio client will get me the names of the vio servers ? (2 Replies)
Discussion started by: samsungsamsung
2 Replies

4. AIX

VIO server on p520

trying to put VIO server software into this p520, firmware upgraded to the latest and greatest..SF240_415_318 , I think a few questions, on this practice AIX machine on AIX 7.1 VIO can only be installed if ASMI or HMC is running ??? if so, perhaps ASMI is much simpler, since I will need to... (2 Replies)
Discussion started by: ppchu99
2 Replies

5. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

6. AIX

Mirroring vio server

Hi, I would like to know installing vio server on local disk and mirroring rootvg, if I am creating AIX VIO CLIENT(lpar), and any of single local hard disk failuare. will it affect lpars? will lpars able to boot. what needs to be done? (1 Reply)
Discussion started by: manoj.solaris
1 Replies

7. Red Hat

Server uptime is showing 0hr but server not rebooted

Hi One of our server is showing the uptime 0hr 5mints there is no log in /var/log/messages there is no log in command "last" kernel version is 2.4.9 (RH2.1 AS) What could be the reason for this. is this issue is related to uptime counter reached max how to verify this. Best Regards KVK (4 Replies)
Discussion started by: venikathir
4 Replies

8. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies

9. UNIX for Dummies Questions & Answers

Script to run in vio server

I want to grab all the luns in vscsi disks from vio that are assigned to client lpars. They are not powerpath disks. Now when I do lspv as root in vio server I see 956 disks..the problem right now is that each disks lun are in hex so when I do lscfg vpl from vio..the FRU number is on hex. Can... (3 Replies)
Discussion started by: pregmi
3 Replies

10. AIX

Replacing HBA in the VIO server

Hi Experts, Kind of embarrassed to ask this , it's been a while I've done this . Can anyone verify below procedure to replace HBA in the VIO server. Many client LPARs are using this HBA for NPIV . Please correct me if I am wrong . Thanks in Advanced Identify the HBA (did that) Unconfigure the... (2 Replies)
Discussion started by: JME2015
2 Replies
scconf_transp_adap_ce(1M)				  System Administration Commands				 scconf_transp_adap_ce(1M)

NAME
scconf_transp_adap_ce - configure the ce Sun Ethernet transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure ce adapters as cluster transport adapters. These adapters can be used with transport types dlpi. The ce adapter is VLAN capable. A ce adapter connects to a transport switch or to another ce adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured by using scconf, scinstall, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node ID hosting the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), ce(7D) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_ce(1M)
All times are GMT -4. The time now is 04:30 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy