There is also the sed / regex route:
==> Note that the file is still in DOS format, which means there is a CR character before the LF character at the end.
So first you would need to convert it to UNIX format:
By using a single dot at the end to match the CR character, it can be made to work with a DOS format file:
or
But the proper way is to convert first.
Last edited by Scrutinizer; 08-27-2014 at 03:19 AM..
This User Gave Thanks to Scrutinizer For This Post:
Hi ,
I have a file :
CSCH74000.00
CSCH74000.00
CSCH74100.00
CSCH74000.00
CSCH74100.00
CSCH74000.00
CSCH74000.00
CSCH74100.00
CSCH74100.00
CSCH74100.00
I have to put a delimiter( say comma) in between after 6th character:
CSCH74,000.00
CSCH74,000.00
CSCH74,100.00 (2 Replies)
I am trying to parse a Fixed width file with data as below. I am trying to assign column values from each record to variables. When I parse the data, the spaces in all coumns are dropped. I would like to retain the spaces as part of the dat stored in the variables. Any help is appreciated.
I... (4 Replies)
Hi,
I have a fixed width file with some records as given below:
" 1000Nalsdjflj243324jljlj"
"-0300Njfowjljl309933fsf"
" 0010Njsfsjklj342344fsl"
I want to sum-up first field values(i.e from 2nd character to 6th character)of each record.
so for the above file i want to add (1000 - 300+... (2 Replies)
Hi All,
I have created a script which generates FIXED-WIDTH file by executing Oracle query.
SELECT RPAD(NVL(col1,CHR(9)),20)||NVL(col2,CHR(9))||NVL(col3,CHR(9) FROM XYZ
It generates the data file with proper alignment. But if same file i transfer to windows server or Mainframe... (5 Replies)
I am trying to determine what would be a fast and simple way to manipulate data that comes in a fixed width format. This data has 6 segments within a record. Each record needs to written out with a header and the 6 segments. Based on the value in column #6 the fields will be defined accordingly.... (4 Replies)
Hi Guys
I am checking the treads to get the answer but i am not able to get the answer for my question.
I have two files. First file is a pattern file and the second file is the file i want to search in it. Output will be the lines from file2.
File1:
P2797f12af 44751228... (10 Replies)
I have a fixed width file of length 53. when is try to get the lengh of the record of that file i get 2 different answers.
awk '{print length;exit}' <File_name>
The above code gives me length 50.
wc -L <File_name>
The above code gives me length 53.
Please clarify on... (2 Replies)
I have a fixed with file with header & trailer length having the same length of the detail record file.
The details record length of this file is 24, for Header and Trailer the records will be padded with spaces to match the record length of the file
Currently I am adding 3 spaces in header... (14 Replies)
Discussion started by: ginrkf
14 Replies
LEARN ABOUT DEBIAN
irsend
IRSEND(1) User Commands IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.9.0-pre1 October 2010 IRSEND(1)