Hi,
I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7).
I extend my vg vg000 (on the partition) and add the 2 hdisks.
I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
Hello guys,
It would be so nice of you if someone can provide me with these informations.
1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
I have a DUAL VIO ( IBM Virtual I/O ) setup on p 570.
Two Vio server ( VIOS ) and many LPAR clients.
VIO ( latest version + service pack + applied the fix ) and AIX 6.1 ML2
When both VIOs are running, and if I turn on a Client LPAR, the LPAR hangs at LED 25b3 for more than 1 hour then it... (2 Replies)
Hello,
I have created mapping of 2 virtual adapters for Lpars using following command:
mkvdev -vdev ipanalyzerlv1 -vadapter vhost11
mkvdev -vdev ipanalyzerlv -vadapter vhost13
The above two commands were succesfull
but when I want to map the third virtual device to the same Lpar than... (3 Replies)
Hi All,
Besides the licenses on VIO and LPAR. What's the main difference with the two? I have installed VIO, my manager told me so, because it's like a free hypervisor but I never installed LPAR before. How do you install it? And if you can give more info on the two, that would be great.
... (5 Replies)
I am trying to install AIX 5.3 on one of the LPARs through VIOS but I get this error 0518
Reference Code Selection
0518 (Time stamp: 12/18/12 12:10:20 AM UTC)
Starting kernel (Time stamp: 12/18/12 12:10:15 AM UTC)
AIX is starting. (Time stamp: 12/18/12 12:10:15 AM... (10 Replies)
Hi,
Just joined to new company with one Power 720 Express (8202-E4C) server and have no much experience with IBM systems.
I am trying to move everything I mentioned to different subnet as required by customer contract (currently sitting on same subnet as company lan). Access to this subnet will... (8 Replies)
Hi everybody,
I have Power5 server with 4 internal hdisks each of 70Gb.
VIOS server was installed via Virtual I/O Server Image Repository on the HMC.
HMC release - 7.7.0
VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Hello,
In my environment, I have 2 VIOS. There is 1 lpar uses the first VIOS. Now we would like to move it to second VIOS.
My question is, can we migrate the virtual FC on the lpar to second VIOS?
If not, we have to create new virtual FC on second VIOS and map it to the lpar. This also... (3 Replies)
Discussion started by: Phat
3 Replies
LEARN ABOUT LINUX
filesystem
filesystem(7) Miscellaneous Information Manual filesystem(7)NAME
filesystem - event signalling that filesystems have been mounted
SYNOPSIS
filesystem [ENV]...
DESCRIPTION
The filesystem event is generated by the mountall(8) daemon after it has mounted all filesystems listed in fstab(5). mountall(8) emits
this event as an informational signal, services and tasks started or stopped by this event will do so in parallel with other activity.
EXAMPLE
A service that wishes to be running once filesystems are mounted might use:
start on filesystem
SEE ALSO mounting(7)mounted(7)virtual-filesystems(7)local-filesystems(7)remote-filesystems(7)all-swaps(7)mountall 2009-12-21 filesystem(7)