Sponsored Content
Operating Systems AIX SSA_DEVICE_ERROR - What could be? Post 302909690 by zaxxon on Friday 18th of July 2014 10:23:52 AM
Old 07-18-2014
Just found this one to (maybe) make sure, that pdisk15 is the culprit or soon to be one:

Code:
ssa_diag command 
Purpose
        To Run Diagnostic style tests to a specified device.

[Syntax, Description]

ssa_diag is found in /usr/lpp/diagnostics/bin and is invoked:

 ssa_diag -l pdiskX
or
 ssa_diag -l ssaX

additional parameters are:

 [-a] : which causes the adapter to be reset
if it is an adapter being tested. (This has no effect on a disk test)
 [-u] : which forces a disk reservation to be broken, if it is a disk
which is being tested. (This has no effect on an adapter test)
 [-s] : This can only be used with a disk device, and requests the output
of the power status. (This flag cannot be used with the -a or -u flag)

Output

if an error is detected, then a message such as:

ssa0 SRN 42500

will be sent to stdout. If there is no problem, then there is no message
sent to stdout.
A non-zero return code indicates an error, for which output will be sent to
stderr.

Power Status output (to stdout) is as follows:
        pdisk0 0                which means pdisk0 Power good
        pdisk0 1                which means pdisk0 Lost Redundancy
        pdisk0 2                which means pdisk0 Failed

This User Gave Thanks to zaxxon For This Post:
 
raidctl(1M)						  System Administration Commands					       raidctl(1M)

NAME
raidctl - RAID hardware utility SYNOPSIS
raidctl -c disk1 disk2 raidctl -d disk1 raidctl [-f] -F filename controller... raidctl -l [controller...] DESCRIPTION
The raidctl utility creates, deletes, or displays RAID volumes of the LSI1030 HW Raid controllers that include RAID support. The utility also updates firmware/fcode/BIOS for both RAID and non-RAID controllers. The raidctl utility requires privileges that are controlled by the underlying file-system permissions. Only privileged users can manipulate the RAID system configuration. If a non-privileged user attempts to create or delete a RAID volume, the command fails with EPERM. Without options, raidctl displays the current RAID configuration on all exisiting controllers. OPTIONS
The following options are supported: -c disk1 disk2 (for on board) Create a mirror using disk1 and disk2. Replace the contents of disk2 with the contents of disk1. Specify disk1 and disk2 in canonical form, for example, c0t0d0. When you create a a RAID volume, the RAID volume assumes the identity of the first target in the disk pair (disk1). The second target (disk2) disappears from the system. Therefore, the RAID volume appears as one disk. To have a successful RAID creation, there must not already be a RAID configuration present on the specified controller. Additionally, the secondary disk must not be mounted, as it has all its data erased and replaced with the primary disk's data. -d disk1 (for on board) Delete the RAID volume specified as disk1. Specify disk1 in canonical form, for example, c0t0d0. -f (for HBA) Force an update. Do not prompt. -F filename controller (for HBA) Update the firmware running on the specified controller (controller). -l [controller ...] (for on board) List the system's RAID configuration. If controller is specified, list RAID configurations for controller. Output from the -l lists the following information: RAID Volume Displays logical RAID volume name. RAID Status Displays RAID status as either RESYNCING (disks are syncing), DEGRADED RAID is operating with reduced functionality), OK (operating optimally), or FAILED (non-functional). RAID Disk Displays RAID disk name. Disk Status Displays disk status as either OK or FAILED. EXAMPLES
Example 1: Creating the RAID Configuration The following command creates the RAID configuration: # raidctl -c c0t0d0 c0t1d0 RAID Volume 'c0t0d0' created Example 2: Displaying the RAID Configuration The following command displays the RAID configuration: # raidctl RAID RAID RAID Disk Volume Status Disk Status ---------------------------------------- c0t0d0 RESYNCING c0t0d0 OK c0t1d0 OK Example 3: Deleting the RAID Configuration The following command deletes the RAID configuration: # raidctl -d c0t0d0 RAID Volume 'c0t0d0' deleted Example 4: Updating Flash Images on the Controller The following command updates flash images on the controller: # raidctl -F lsi1030.fw 0 Update flash image on controller 0? (y/N): y Flash updated successfully EXIT STATUS
The following exit values are returned: 0 Successful completion. 1 Invalid command line input. 2 Request operation failed. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ SEE ALSO
attributes(5) System Administration Guide: Basic Administration SunOS 5.10 17 Aug 2004 raidctl(1M)