Sponsored Content
Operating Systems AIX VIOS - fibre adapters not seeing luns Post 302903370 by aixkidbee on Tuesday 27th of May 2014 07:18:05 AM
Old 05-27-2014
Bakunin, the SAN team advised me they don't do port mapping. They do WWN mapping. So, whatever port they plug into shouldn't matter. (I'm not 100% sure of this). Think of it like this. Fabric switch A - has WWN mapping enabled. SAN adds my MAC address to Fabric switch A. Fibre cable from my FC adapter to Fabric switch A and WWN doesn't come online.
Does Xray advise still apply?

I am looking for more information in regards to 3PAR and 'server logged out adapter' as Xray mentioned.
 

6 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

4 x fibre cards elimination

Hi, I have variables like mentioned below and want to separate as mentioned in output. var1="4 x fibre cards" var2="2 fibre cards" var3="6 - fibre cards" var4="4 x dual-port" I have variables like this.I want to separate numbers from this and fibre cards from this. output has to be... (4 Replies)
Discussion started by: ajilesh
4 Replies

2. AIX

20EE0008 : No adapters found Adapter, Riser, System Bd.

Hello, When I try to upgrade AIX from 5.1 to 5.3 I get this error message 20EE0008 : No adapters found Adapter, Riser, System Bd. Anyone know anything about it ? (1 Reply)
Discussion started by: filosophizer
1 Replies

3. Red Hat

Designating Default Gateway for multiple networks/adapters

Hi I have 4 NIC's connected to my RHEL 5.3 server. Two on one subnet creating bond0, and two on a second subnet which create bond1. Both bonds are set to use DHCP to obtain IP addresses. Here is the config file for ifcfg-bond0: DHCP_HOSTNAME=rrnltshckvmx001 DEVICE=bond0 BOOTPROTO=dhcp... (2 Replies)
Discussion started by: Padow
2 Replies

4. Windows & DOS: Issues & Discussions

Order of Adapters in Windows 7

I am trying to get my boss' ipad to print on our local printers, and rapidly coming to loathe the product. After several false starts I'm attempting to use the free WePrint application, running on a Windows machine, to "forward" our printers from it to the ipad over the local network. I've hit... (2 Replies)
Discussion started by: Corona688
2 Replies

5. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies

6. AIX

VIO SEA Adapters

hi guys BTW pretty new to VIO I inherited 2 I BM Power Server - blades PS701 - One is already configured using en8 # lsdev -Cc adapter | grep ent ent0 Available Logical Host Ethernet Port (lp-hea) ent1 Available Logical Host Ethernet Port (lp-hea) ent2 Available 04-20... (8 Replies)
Discussion started by: karlochacon
8 Replies
scconf_transp_adap_sci(1M)				  System Administration Commands				scconf_transp_adap_sci(1M)

NAME
scconf_transp_adap_sci - configure the sci cluster transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure sci SCI-PCI adapters as cluster transport adapters. These adapters can be used with the dlpi transport type. The adapter name is sciN, for example, sci0. Do not use scidN as the adapter name. An sci adapter can only be connected to another sci adapter or to an SCI switch. When an sci adapter is connected to an SCI switch, it is important that you specify the correct port name when referring to a port on the switch as an endpoint argument to the scconf or scinstall utility. The port name must match the port number on the SCI switch (the number that is printed on the switch itself). Failure to give the correct port name could result in the operation failing. The result of providing an incorrect port name will be the same as you would see if the cable between the adapter and the switch were removed. There are no user-configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scconf_transp_jct_dolphinswitch(1M), scinstall(1M) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_sci(1M)
All times are GMT -4. The time now is 01:47 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy