Hi,

here some hints:

- Did you used the same switch ports in the data center?
- (if not) Did you checked the speed, fillword, NPIV settings for the used switch ports?
- See your storage admin your wwns as 'logged in'?
- Maybe you musst reenable a logged out server adapter on storage level (i don't know which Storage you use)


PS
Can you please post the output from following commands:
Code:
lspath
fcstat <fcsX>        # for both adapters
lscfg -vl <hdiskX>   # for one of the disk with a failed path

Regards

Last edited by -=XrAy=-; 05-27-2014 at 05:48 AM.. Reason: add commands
 

6 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

4 x fibre cards elimination

Hi, I have variables like mentioned below and want to separate as mentioned in output. var1="4 x fibre cards" var2="2 fibre cards" var3="6 - fibre cards" var4="4 x dual-port" I have variables like this.I want to separate numbers from this and fibre cards from this. output has to be... (4 Replies)
Discussion started by: ajilesh
4 Replies

2. AIX

20EE0008 : No adapters found Adapter, Riser, System Bd.

Hello, When I try to upgrade AIX from 5.1 to 5.3 I get this error message 20EE0008 : No adapters found Adapter, Riser, System Bd. Anyone know anything about it ? (1 Reply)
Discussion started by: filosophizer
1 Replies

3. Red Hat

Designating Default Gateway for multiple networks/adapters

Hi I have 4 NIC's connected to my RHEL 5.3 server. Two on one subnet creating bond0, and two on a second subnet which create bond1. Both bonds are set to use DHCP to obtain IP addresses. Here is the config file for ifcfg-bond0: DHCP_HOSTNAME=rrnltshckvmx001 DEVICE=bond0 BOOTPROTO=dhcp... (2 Replies)
Discussion started by: Padow
2 Replies

4. Windows & DOS: Issues & Discussions

Order of Adapters in Windows 7

I am trying to get my boss' ipad to print on our local printers, and rapidly coming to loathe the product. After several false starts I'm attempting to use the free WePrint application, running on a Windows machine, to "forward" our printers from it to the ipad over the local network. I've hit... (2 Replies)
Discussion started by: Corona688
2 Replies

5. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies

6. AIX

VIO SEA Adapters

hi guys BTW pretty new to VIO I inherited 2 I BM Power Server - blades PS701 - One is already configured using en8 # lsdev -Cc adapter | grep ent ent0 Available Logical Host Ethernet Port (lp-hea) ent1 Available Logical Host Ethernet Port (lp-hea) ent2 Available 04-20... (8 Replies)
Discussion started by: karlochacon
8 Replies
scconf_transp_adap_e1000g(1M)				  System Administration Commands			     scconf_transp_adap_e1000g(1M)

NAME
scconf_transp_adap_e1000g - configure the Intel PRO/1000 network adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure e1000g Intel PRO/1000 network adapters as cluster transport adapters. These adapters can only be used with transport type dlpi. The e1000g based network adapter connects to a transport switch or to another Ethernet adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured by using scconf, scinstall, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node identifier that hosts the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), e1000g(7D) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_e1000g(1M)
All times are GMT -4. The time now is 09:16 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy