Hi,
i use the IBM System Planning Tool to understand Your configuration and "problem".
1. Which Storage Backplane do you use (EJ0D, EJ0E or EJ0F) ?
2. In all cases max. 6 SFF Drives are possible - do you use a additional IO-Drawer?
The IBM System Planning Tool shows that P1-C18 points to the SAS Controller and P1-C8 to the GX++ Slot.
Regards
10 More Discussions You Might Find Interesting
1. AIX
I've been trying to get AIX 5.3 installed on a vio partition. I tried one partition that I created, and another one that already had AIX 5.3 on it. In both cases, the install seems to be successful, but when it tries to reboot, it gets to the kernel starting phase, I can see the kernel size, and... (0 Replies)
Discussion started by: Morella
0 Replies
2. AIX
I have a script running remotely using viosvrcmd command on hmc to back up the VIO servers. these are the steps involved
1. Mount the NFS directory on to the VIO server
2. run backupios command
3. un mount the directory
I am stuck up in the 3rd step. I am not able to unmount the nfs... (6 Replies)
Discussion started by: balaji_prk
6 Replies
3. AIX
Hi,
I want to know wheather partition size for installation of vio client can be specified on vio server
example
If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies
4. AIX
In a dual vio, how will u know one lpar is in which vio? (1 Reply)
Discussion started by: shobhan.murthy
1 Replies
5. AIX
I am planning carving out dual VIO servers on a P750 based and would like to know how to allocate internal disks to the VIOS. This has 4 internal disks and I would to assign 2 disks to each VIO.
This is what I was thinking of assigning . Any advise?
vio1
U5802.001.9K8H757-P1-C1 PCI-E x8... (17 Replies)
Discussion started by: mk8570
17 Replies
6. AIX
I have same lun (hdisk3) assigned to 2 vios server (dual vio server) and this is mapped to the client lpar. I have sddpcm on the VIO.
On the VIOA, the attributes for fscsi1 and fscsi3 are set to fast_fail and dyntrk is set to yes
Now, if I do a lqueryvg -Atp on the hdisk3, I get a "DISK... (4 Replies)
Discussion started by: mk8570
4 Replies
7. Red Hat
I am working in AIX. In a P series machine both aix and linux os can install.. specific command is there for aix to list out the vio servers details mapped in a frame(ie. lssrc "IBM.ManagementServer", like that..) is there any command is der to list out vio servers details in linux or how to find... (1 Reply)
Discussion started by: muralikrish
1 Replies
8. AIX
Hi
In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID.
Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies
9. AIX
Hi,
I am facing an issue in vio server. When I run
bosboot -ad /dev/hdisk0
I am getting an error
trustchk: Verification of attributes failed: /usr/sbin/bootinfo
: accessauths
regards,
vjm
Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies
10. AIX
We've got two datacenters and in every datacenter 2 VIOs.
The VIO manages the I/O of the LPARs. So: Is it possible to reboot the VIO without shuting down an LPAR:wall: (4 Replies)
Discussion started by: DiViN3
4 Replies
MPII(4) BSD Kernel Interfaces Manual MPII(4)
NAME
mpii -- LSI Logic Fusion-MPT Message Passing Interface II
SYNOPSIS
mpii* at pci? dev ? function ?
DESCRIPTION
The mpii driver provides support for storage controllers using the LSI Logic Fusion-MPT Message Passing Interface II family of chipsets:
- LSISAS2004, LSISAS2008
These chipsets can be found on the following controllers:
- Dell PERC H200
- LSI SAS 9200-8e, SAS 9211-4i, SAS 9211-8i
Some models of these controllers have varying degrees of support for RAID 0 and RAID 1.
mpii supports monitoring of the logical disks in the controller through the bioctl(8) and envstat(8) commands.
EVENTS
The mpii driver is able to send events to powerd(8) if a logical drive in the controller is not online. The state-changed event will be sent
to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8)
HISTORY
The mpii driver first appeared in OpenBSD 4.7.
AUTHORS
The mpii driver was written by James Giannoules and Mike Belopuhov.
BUGS
The chips supported by mpii do not use a SCSI-like identifier. Instead they use an opaque ID and leave discovery order up to the operating
system. The code to handle this is currently not implemented and therefore it is not a good idea to run this driver on a multi-boot machine
or with more than 1 drive.
BSD
April 19, 2012 BSD