Sponsored Content
Operating Systems SCO How to change raid controller driver ? (hardware change) Post 302875173 by jgt on Monday 18th of November 2013 05:41:01 PM
Old 11-18-2013
As a note of explanation, this procedure applies only to host bus adapters, not RAID controllers such as the Mylex DAC960.
Also when the host bus adapter is changed, the new adapter may not see the drive with the same geometry, so it may be necessary to use the 'biosgeom' boot string, and then run 'dparam' to make the change permanently.
This User Gave Thanks to jgt For This Post:
 

10 More Discussions You Might Find Interesting

1. IP Networking

Ip Addresses With Hardware Change

I have 2 identical printers with the same IP on my network. One is only used as a backup for the primary printer and both are never on line at the same time. The goal was to always keep only 1 on and have an use the other printer as an immediate backup if necessary. But when I switch the cable I... (4 Replies)
Discussion started by: golfs4us
4 Replies

2. SCO

ultra 320 scsi raid controller driver for sco 5.0.6

I am facing a problem to install sco 5.0.6 in Dell Power Edge SC1420 which raid controller is ultra 320 scsi raid controller . how/from where to download the ultra 320 scsi raid controller driver for sco 5.0.6. Plz help with any idea karzon (1 Reply)
Discussion started by: karzon
1 Replies

3. SCO

driver needed for hp smartarry p200i sas raid controller

recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
Discussion started by: prakrithi
3 Replies

4. UNIX for Dummies Questions & Answers

Samba change domain controller

Hello people i have a samba and they changed domain controller from a windows 2003 to a windows 2008, there is a problem with the version of samba maybe incompatibilities i dont know what show me this domain_client_validate: unable to validate password for user xxxx in domain xxxx to Domain... (0 Replies)
Discussion started by: enkei17
0 Replies

5. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

8. IP Networking

C - IP change during a hardware refresh?

Hi All, I was told to perform analysis for IP change during a hardware refresh? Does the IP change when a hardware refresh is performed? if Yes, why? (5 Replies)
Discussion started by: visitsany
5 Replies

9. Linux

How to change ODBC Driver Manager?

Hi Forum. I have been searching this information for a while but to no avail. I'm running the following command odbcinst -j on a Linux box and get the following: unixODBC 2.3.0 DRIVERS............: //opt/Progress/DataDirect/Connect64_for_ODBC_71/odbcinst.ini SYSTEM DATA SOURCES:... (2 Replies)
Discussion started by: pchang
2 Replies

10. SCO

SCO OS 6 Driver for LSIL SAS1064E Raid Controller

Hi all, A client has an SCO OpenServer Server 6.0, that is running on an HP ProLiant Box and they lost the root password. Its equipped with a Doal-Core Intel Pentium Processor. They don't have any media or emergency disk anymore. I tried to boot with the CD Rom, then "Tools", then exit to... (7 Replies)
Discussion started by: thm2222
7 Replies
ASR(4)							   BSD Kernel Interfaces Manual 						    ASR(4)

NAME
asr -- driver for Adaptec I2O based SCSI/ATA host bus adapters SYNOPSIS
device asr DESCRIPTION
The Adaptec asr driver provides access to disks and disk arrays controlled by I2O based host bus adapters and SmartRAID SCSI RAID adapters through the standard SCSI disk da(4) interface. The supported adapters provide 64 bit PCI, Compact PCI, Zero Channel PCI, and up to four channels of Ultra2, Ultra 160, or Ultra320 SCSI, or two channels of 1GB Fibre. All support RAID-0, RAID-1, RAID-10, RAID-5 and RAID-50 arrays. All SCSI target types are supported. For the ATA based controllers, one IDE drive per channel is supported. Hot-swapping of IDE drives is not supported at this time. All host bus adapters must be configured before they can be used with any operating system. Please contact Adaptec directly to obtain the latest information on configuration utilities for the adapters. Currently there are both a Motif based GUI configuration utility and a CLI based configuration utility available from the Adaptec Web site. The cards and arrays can also be configured via the BIOS based configura- tion tool (SMOR). HARDWARE
The adapters currently supported by the asr driver include the following: o Adaptec Zero-Channel SCSI RAID 2000S, 2005S, 2010S, 2015S o Adaptec SCSI RAID 2100S, 2110S o Adaptec ATA-100 RAID 2400A o Adaptec SCSI RAID 3200S, 3210S o Adaptec SCSI RAID 3400S, 3410S o Adaptec SmartRAID PM1554 o Adaptec SmartRAID PM1564 o Adaptec SmartRAID PM2554 o Adaptec SmartRAID PM2564 o Adaptec SmartRAID PM2664 o Adaptec SmartRAID PM2754 o Adaptec SmartRAID PM2865 o Adaptec SmartRAID PM3754 o Adaptec SmartRAID PM3755U2B / SmartRAID V Millennium o Adaptec SmartRAID PM3757 o DEC KZPCC-AC (LVD 1-ch, 4MB or 16MB cache), DEC KZPCC-CE (LVD 3-ch, 64MB cache), DEC KZPCC-XC (LVD 1-ch, 16MB cache), DEC KZPCC-XE (LVD 3-ch, 64MB cache) -- rebadged SmartRAID V Millennium FILES
/dev/asr* Adaptec SCSI RAID control nodes NOTES
The ATA based controllers present their devices as SCSI-like devices via CAM. For IDE drives attached to these cards, a subset of standard SCSI commands and mode pages are understood via translation performed in the card's firmware. SEE ALSO
da(4) HISTORY
The asr (Adaptec SCSI RAID) driver first appeared as the dpti2o driver under BSDi BSD/OS 3.2, then under FreeBSD 2.2.8 and was ported over to the CAM layer represented in 4.0. AUTHORS
The asr driver was kindly donated by Adaptec and is maintained by Mark Salyzyn <mark_salyzyn@adaptec.com>. This manual page was written by Mark Salyzyn and fixed up by Jeroen Ruigrok van der Werven <asmodai@FreeBSD.org>. BSD
July 14, 2004 BSD
All times are GMT -4. The time now is 11:14 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy