11-18-2013
Quote:
This should help
http :// wdb1.sco.com/kb/showta?taid=105356&qid=1383882812&sid=2009743988&pgnum=1
Hello jgt's, the truth is that there was no looking on TA, after writing the post found
http : // ask.adaptec.com/app/answers/detail/a_id/2145 (which is almost the same procedure) and it worked.
Recent edit / etc / conf / sdevice.d / alad to disable the driver
Thank you.
10 More Discussions You Might Find Interesting
1. IP Networking
I have 2 identical printers with the same IP on my network. One is only used as a backup for the primary printer and both are never on line at the same time. The goal was to always keep only 1 on and have an use the other printer as an immediate backup if necessary. But when I switch the cable I... (4 Replies)
Discussion started by: golfs4us
4 Replies
2. SCO
I am facing a problem to install sco 5.0.6 in Dell Power Edge SC1420 which raid controller is ultra 320 scsi raid controller .
how/from where to download the ultra 320 scsi raid controller driver for sco 5.0.6.
Plz help with any idea
karzon (1 Reply)
Discussion started by: karzon
1 Replies
3. SCO
recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
Discussion started by: prakrithi
3 Replies
4. UNIX for Dummies Questions & Answers
Hello people i have a samba and they changed domain controller from a windows 2003 to a windows 2008, there is a problem with the version of samba maybe incompatibilities i dont know what show me this
domain_client_validate: unable to validate password for user xxxx in domain xxxx to Domain... (0 Replies)
Discussion started by: enkei17
0 Replies
5. SCO
So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller.
First, I downloaded the megasas driver from SCO and installed it on the old system.
Then I created a new Microlite Edge emergency boot cd with the new driver on it.
I... (2 Replies)
Discussion started by: jgt
2 Replies
6. AIX
Hello,
I have a scsi pci x raid controller card on which I had created a disk array of 3 disks
when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk )
suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies
7. Red Hat
Hello,
I want to delete a RAID configuration an old server has.
Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton?
I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
8. IP Networking
Hi All,
I was told to perform analysis for IP change during a hardware refresh?
Does the IP change when a hardware refresh is performed?
if Yes, why? (5 Replies)
Discussion started by: visitsany
5 Replies
9. Linux
Hi Forum.
I have been searching this information for a while but to no avail.
I'm running the following command odbcinst -j on a Linux box and get the following:
unixODBC 2.3.0
DRIVERS............: //opt/Progress/DataDirect/Connect64_for_ODBC_71/odbcinst.ini
SYSTEM DATA SOURCES:... (2 Replies)
Discussion started by: pchang
2 Replies
10. SCO
Hi all,
A client has an SCO OpenServer Server 6.0, that is running on an HP ProLiant Box and they lost the root password.
Its equipped with a Doal-Core Intel Pentium Processor. They don't have any media or emergency disk anymore.
I tried to boot with the CD Rom, then "Tools", then exit to... (7 Replies)
Discussion started by: thm2222
7 Replies
LEARN ABOUT OPENSOLARIS
rdc.cf
rdc.cf(4) File Formats rdc.cf(4)
NAME
rdc.cf - Availability Suite Remote Mirror software configuration file
DESCRIPTION
The rdc.cf is an optional configuration file that supplies the sndradm(1M) command with details of the volume sets to be operated on.
Inrdc.cf, the volume sets and their host locations are defined in the following format:
post pdevice pbitmap shost sdevice sbitmap protocol mode options
The rdc.cf fields are:
phost (primary host)
Server on which the primary volume resides.
pdevice (primary device)
Primary volume partition to be copied. Specify only full path names (for example, /dev/rdsk/c0t1d0s2).
pbitmap (primary bitmap)
Volume partition in which the bitmap (scoreboard logs) of the primary partition is stored. Specify only full path names (for exam-
ple, /dev/rdsk/c0t1d0s3).
shost (secondary host)
Server on which the secondary volume resides.
sdevice (secondary device)
Secondary volume partition. Specify only full path names (for example,/dev/rdsk/c0t1d0s4).
sbitmap (secondary bitmap)
Volume partition in which the bitmap (scoreboard logs) of the secondary file is stored. Specify only full path names (for example,
/dev/rdsk/c0t1d0s5).
protocol
Network transfer protocol. Specify IP.
mode
Remote Mirror operating mode. Sync is the Remote Mirror mode where the I/O operation is not confirmed as complete until the remote
volume has been updated. Async is the other Remote Mirror mode, in which the primary host I/O operation is confirmed as complete
before updating the remote volume.
options
A consistency group name can be specified using the g character. A disk queue volume partition can be specified using the q character,
using full path name only (/dev/rdsk/c0t1d0s5). Without the q character set will default to memory base queue. When running on
a clustered system, a cluster resource group tag can be specified using the C character.
These options have the following syntax:
[g io_groupname] [q queue_volume][C ctag]
Note -
When running on a cluster configuration, the cluster resource group tag is appended to the Remote Mirror set by default.
ATTRIBUTES
See attributes(5) for a description of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Architecture |x86 |
+-----------------------------+-----------------------------+
|Availability |SUNWrdcu |
+-----------------------------+-----------------------------+
|Interface Stability |Committed |
+-----------------------------+-----------------------------+
SEE ALSO
sndradm(1M), sndrd(1M), attributes(5)
SunOS 5.11 08 Jun 2007 rdc.cf(4)