Hello All,

Our servers having emc clarion for the data disks. Is that possible to see those san disks raid level from AIX ?

Am having AIX 6.1 and EMC clarion 5.5.


Regards,
Gowtham.G
 

10 More Discussions You Might Find Interesting

1. AIX

RAID level of array = false?

I created a RAID 5 array and when I list out the attributes of the "hdisk" it reports back raid_level = 5 but the RAID level of the array = false. What does this actually indicate about my array? I've never paid much attention to this until now since I have a disk reporting failure I want to make... (0 Replies)
Discussion started by: scottsl
0 Replies

2. AIX

AIX disk less with SAN

Hi All, I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX? Is that going to boot on SAN rootvg volume? Thanks in advance, itik (3 Replies)
Discussion started by: itik
3 Replies

3. AIX

AIX 5.2/5.3 - rootvg on SAN disk - pros and cons

We are considering a DR strategy of booting AIX 5.3 and 5.3 logical partitions from EMC Symmetrix SAN disks, so that we can replicate via SRDF to a recovery site. Has anyone tried configuring AIX 5.x systems to boot from SAN disk? If so, can you provide any information on the pros and cons of... (6 Replies)
Discussion started by: jjgarrot
6 Replies

4. AIX

IBM FastT600 SAN - RAID 5 Storage Manager Client v08.33.G5.03 - Recovery?

To summarize the problem: The "IBM FastT Storage Manager Client v8" shows that our Disk Farm is arranged into 6 logical drives each in a RAID 5 configuration. This software also shows that 5 of the 6 logical drives (from Disk Farm) are in a error state: "Failed Logical Drive - Drive Failure".... (1 Reply)
Discussion started by: aix-olympics
1 Replies

5. AIX

How to upgrade AIX Firmware & TL Maintenance Level in AIX

Steps to upgrade AIX TL ( technology Level ) / Maintenance Level in AIX ( including Firmware HMC VIOS ) This article or post covers upgrades for - Hardware Management Console ( HMC ) - Firmware ( also known as microcode ) - VIO ( Virtual I/O Server = PowerVM ) - AIX Version, Technology... (2 Replies)
Discussion started by: filosophizer
2 Replies

6. Solaris

I/O Error on SAN Disk

Hi, I have a production solaris 10 SPARC system (portal). Yesterday legato/Networker gave an I/O Error on one of the files on its SAN mounted disk. I went to that particular file on the system, did an ls and it showed the file. However, ls -l did not work and it said IO error. ... (6 Replies)
Discussion started by: Mack1982
6 Replies

7. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

8. AIX

raid level

Hi Admins, What is the command to check the RAID level in aix 5.3 I have a vg with 5 disks.I want to check the raid level. Regards newaix (1 Reply)
Discussion started by: newaix
1 Replies

9. AIX

SAN Disk Appearing double in AIX

Hello Folks, I have directly connected my IBM Pseries AIX machine to SAN Storage I have a dual port Fibre Channel Adapter Connected both fiber ports to SAN Box IBM DS4500 Controller A & Controller B Using IBM DS storage manager client 10 -- created one logical disk and assigned to a... (18 Replies)
Discussion started by: filosophizer
18 Replies

10. AIX

San disk appearing double in old AIX

Hi guys, :) I'm a studient in IT field (AIX) I'm trying to map a LUN from a SAN (DS3400) to an AIX server (5300-04-00) I know there is no MPIO on this version of AIX, and i see double my LUN from the SAN root@localhost # lscfg | grep hdisk + hdisk7 ... (13 Replies)
Discussion started by: Tharsan
13 Replies
VGREDUCE(8)						      System Manager's Manual						       VGREDUCE(8)

NAME
vgreduce - reduce a volume group SYNOPSIS
vgreduce [-a|--all] [-A|--autobackup y|n] [-d|--debug] [-h|-?|--help] [--removemissing] [-t|--test] [-v|--verbose] VolumeGroupName [Physi- calVolumePath...] DESCRIPTION
vgreduce allows you to remove one or more unused physical volumes from a volume group. OPTIONS
See lvm for common options. -a, --all Removes all empty physical volumes if none are given on command line. --removemissing Removes all missing physical volumes from the volume group, if there are no logical volumes allocated on those. This resumes normal operation of the volume group (new logical volumes may again be created, changed and so on). If this is not possible (there are logical volumes referencing the missing physical volumes) and you cannot or do not want to remove them manually, you can run this option with --force to have vgreduce remove any partial LVs. Any logical volumes and dependent snapshots that were partly on the missing disks get removed completely. This includes those parts that lie on disks that are still present. If your logical volumes spanned several disks including the ones that are lost, you might want to try to salvage data first by acti- vating your logical volumes with --partial as described in lvm (8). SEE ALSO
lvm(8), vgextend(8) Sistina Software UK LVM TOOLS 2.02.67(2) (2010-06-04) VGREDUCE(8)
All times are GMT -4. The time now is 02:27 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy