Sponsored Content
Full Discussion: Zones are not booting
Operating Systems Solaris Zones are not booting Post 302862345 by verdepollo on Thursday 10th of October 2013 03:18:20 PM
Old 10-10-2013
That definitely looks like a storage issue.

Maybe the disk was disconnected (if it's a LUN), maybe it's just faulty or maybe it is wrongly configured.

Running fsck against the disk could also help or at least give you some pointers on the issue.

There could be a 100+ possible reasons why a disk is showing that error, depending on your infrastructure.

If it's an urgent issue and you have Oracle support I'd suggest you ask for their assistance. They'll most likely ask you to run Explorer and upload the output to their FTP servers.
 

10 More Discussions You Might Find Interesting

1. Solaris

Zones

Hi, I want to wheather there is any command by using that we can reboot all the zones , Example : I have 10 zones, I can reboot all 10 zones by using one command (2 Replies)
Discussion started by: manoj.solaris
2 Replies

2. Solaris

zones

what are the files related to dns zones database file management ? (1 Reply)
Discussion started by: tirupathi
1 Replies

3. Solaris

zones

Hi I need a help in creating a zones.I am trying to create zone in Sun fire T1000 server with single cpu / 8 gb Ram / 73 gb hdd.I am planning to install java based application on two different zones. iam planning to install solaris 10. Can some one suggest what is the best way to create two... (5 Replies)
Discussion started by: solaris8in
5 Replies

4. Solaris

Zones

Hi guys Im using VMware and ive installed solaris 10 in that..ive configured virtual disks in that n im using it..my question is if im gona configure zones in it do i need a seperate NIC card..my virtual interface name is pcn0 and if i create zones can i give pcn0:1 n allocate a seperate... (1 Reply)
Discussion started by: madanmeer
1 Replies

5. Solaris

Zones

Hi Everyone, I need the process of how to add a cpu to a non-global zone or how to add a resource to non-globalzone. Thanks & Regards Padmaja (2 Replies)
Discussion started by: padmaja
2 Replies

6. Solaris

Zones

Hi Everyone, How to create a loopback filesystem in a running non golbalzone? and how to share a diskgroup in veritas ? Thanks & Regards Padmaja (1 Reply)
Discussion started by: padmaja
1 Replies

7. Solaris

Solaris Zones

Hi friends, Actually I faced problem in solaris zone. i was created 4 zones on my server. but one of them is not working ? so, where i wll get the error logs, and how to troubleshoot the problem. i have some kind of urgency. Please reply. (2 Replies)
Discussion started by: rajaramrnb
2 Replies

8. Solaris

zones

how can we know zone is migrate and which files going to update (3 Replies)
Discussion started by: nsusheelgoud
3 Replies

9. Solaris

Zones not booting after server reboot

Hello guys This is my first post. I have very little experience and I woud appreciate your input on this problem. I have a server running Solaris 10. In that server I have 2 zones that work perfectly fine, however, if I reboot the server, the zones don't boot and I have to do it manually. i... (12 Replies)
Discussion started by: designbc
12 Replies

10. UNIX for Beginners Questions & Answers

Zones

haven't work with zones in a while. when shutting down zones from solaris 10 I have to do it from the global zone, but can I just shutdown the global zone and all non global zones will shutdown or do I have to zoneadm -z zonename shutdown for all the non global zones ,then shutdown... (2 Replies)
Discussion started by: goya
2 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated Disk driver SYNOPSIS
device ccd DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you are familiar with how to generate kernels, how to properly configure disks and devices in a kernel configura- tion file, and how to partition disks. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: device ccd # concatenated disk devices As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may instead use it as a kernel loadable module. Simply running ccdconfig(8) will load the module into the kernel. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. Note that mirroring may not be used with an interleave factor of 0. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. The Interleave Factor If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase sequential read/write performance. The interleave factor is expressed in units of DEV_BSIZE (usually 512 bytes). For large writes, the optimum interleave factor is typically the size of a track, while for large reads, it is about a quarter of a track. (Note that this changes greatly depending on the number and speed of disks.) For instance, with eight 7,200 RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for reads. A larger interleave tends to work better when the disk is taking a multitasking load by localizing the file I/O from any given process onto a single disk. You lose sequential performance when you do this, but sequential performance is not usually an issue with a multitasking load. An interleave factor must be specified when using a mirroring configuration, even when you have only two disks (i.e., the layout winds up being the same no matter what the interleave factor). The interleave factor will determine how I/O is broken up, however, and a value 128 or greater is recommended. ccd has an option for a parity disk, but does not currently implement it. The best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. For random-access oriented workloads, such as news servers, a larger interleave factor (e.g., 65,536) is more desirable. Note that there is not much ccd can do to speed up applications that are seek-time limited. Larger interleave factors will at least reduce the chance of having to seek two disk-heads to read one directory or a file. Disk Mirroring You can configure the ccd to ``mirror'' any even number of disks. See ccdconfig(8) for how to specify the necessary flags. For example, if you have a ccd configuration specifying four disks, the first two disks will be mirrored with the second two disks. A write will be run to both sides of the mirror. A read will be run to either side of the mirror depending on what the driver believes to be most optimal. If the read fails, the driver will automatically attempt to read the same sector from the other side of the mirror. Currently ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a sequential load. In an event of a disk failure, you can use dd(1) to recover the failed disk. Note that a one-disk ccd is not the same as the original partition. In particular, this means if you have a file system on a two-disk mir- rored ccd and one of the disks fail, you cannot mount and use the remaining partition as itself; you have to configure it as a one-disk ccd. You cannot replace a disk in a mirrored ccd partition without first backing up the partition, then replacing the disk, then restoring the partition. Linux Compatibility The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves on the raw devices. You will have to give the order of devices and the interleave factor on your own. When in Linux compatibility mode, ccd will convert the interleave factor from Linux terminology. That means you give the same interleave factor that you gave as chunk size in Linux. If you have a Linux md(4) device in ``legacy'' mode, do not use the CCDF_LINUX flag in ccdconfig(8). Use the CCDF_NO_OFFSET flag instead. In that case you have to convert the interleave factor on your own, usually it is Linux' chunk size multiplied by two. Using a Linux RAID this way is potentially dangerous and can destroy the data in there. Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the compatibility layer. However, using this is reasonably safe if you test the compatibility before mounting a RAID read-write for the first time. Just using ccdconfig(8) without mounting does not write anything to the Linux RAID. Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd device using the -n flag. You can mount the file system read-only to check files in there. If all this works, it is unlikely that there is a problem with ccd. Keep in mind that even when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs implemen- tation would still destroy your data. WARNINGS
If just one (or more) of the disks in a ccd fails, the entire file system will be lost unless you are mirroring the disks. If one of the disks in a mirror is lost, you should still be able to back up your data. If a write error occurs, however, data read from that sector may be non-deterministic. It may return the data prior to the write or it may return the data that was written. When a write error occurs, you should recover and regenerate the data as soon as possible. Changing the interleave or other parameters for a ccd disk usually destroys whatever data previously existed on that disk. FILES
/dev/ccd* ccd device special files SEE ALSO
dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), gvinum(8), mount(8), newfs(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD
August 9, 1995 BSD
All times are GMT -4. The time now is 11:44 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy