Anyone run into an issue where a new Solaris 11.1 install on a t5120 will only have access to 2g ram? The system has 16g installed and fmadm isn't reporting any problems. Here's some output that may help.
Oh, and this is a brand new operating system install, there's no zones, ldoms, rcap or the like... Just an out of the box install. This hardware used to have a ldom config on it, but that's been quite a while ago. On a 5120 there's no way for the SP to limit OS access to resources, is there? Or, is there an easy procedure to ensure there's no resource limiting in place?
Code:
dtrapani@atlopscenter:~$ vmstat
kthr memory page disk faults cpu
r b w swap free re mf pi po fr de sr s3 s4 s5 sd in sy cs us sy id
0 0 0 1509776 793296 18 36 0 0 0 0 3 15 0 0 0 1687 6564 2032 2 2 96
Code:
System Configuration: Oracle Corporation sun4v SPARC Enterprise T5120
Memory size: 2048 Megabytes
================================ Virtual CPUs ================================
CPU ID Frequency Implementation Status
------ --------- ---------------------- -------
0 1165 MHz SUNW,UltraSPARC-T2 on-line
1 1165 MHz SUNW,UltraSPARC-T2 on-line
2 1165 MHz SUNW,UltraSPARC-T2 on-line
3 1165 MHz SUNW,UltraSPARC-T2 on-line
4 1165 MHz SUNW,UltraSPARC-T2 on-line
5 1165 MHz SUNW,UltraSPARC-T2 on-line
6 1165 MHz SUNW,UltraSPARC-T2 on-line
7 1165 MHz SUNW,UltraSPARC-T2 on-line
======================= Physical Memory Configuration ========================
Segment Table:
--------------------------------------------------------------
Base Segment Interleave Bank Contains
Address Size Factor Size Modules
--------------------------------------------------------------
0x0 16 GB 4 4 GB MB/CMP0/BR0/CH0/D0
MB/CMP0/BR0/CH1/D0
4 GB MB/CMP0/BR1/CH0/D0
MB/CMP0/BR1/CH1/D0
4 GB MB/CMP0/BR2/CH0/D0
MB/CMP0/BR2/CH1/D0
4 GB MB/CMP0/BR3/CH0/D0
MB/CMP0/BR3/CH1/D0
================================ IO Devices ================================
Slot + Bus Name + Model Speed
Status Type Path
----------------------------------------------------------------------------
MB/NET0 PCIE network-pciex8086,105e --
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0
MB/NET1 PCIE network-pciex8086,105e --
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1
MB/NET2 PCIE network-pciex8086,105e --
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0
MB/NET3 PCIE network-pciex8086,105e --
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1
MB/SASHBA PCIE scsi-pciex1000,58 LSI,1068E --
/pci@0/pci@0/pci@2/scsi@0
MB/RISER1/PCIE1 PCIE SUNW,qlc-pciex1077,2432 QLE2460 --
/pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0
MB/RISER0/PCIE0 PCIE SUNW,qlc-pciex1077,2432 QLE2460 --
/pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0
MB PCIX usb-pciclass,0c0310 --
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0
MB PCIX usb-pciclass,0c0310 --
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,1
MB PCIX usb-pciclass,0c0320 --
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2
============================ Environmental Status ============================
Fan sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/FANBD0/FM0/F0 TACH ok
SYS/FANBD0/FM0/F1 TACH ok
SYS/FANBD0/FM1/F0 TACH ok
SYS/FANBD0/FM1/F1 TACH ok
SYS/FANBD0/FM2/F0 TACH ok
SYS/FANBD0/FM2/F1 TACH ok
SYS/FANBD0/FM3/F0 TACH ok
SYS/FANBD0/FM3/F1 TACH ok
SYS/FANBD1/FM0/F0 TACH ok
SYS/FANBD1/FM0/F1 TACH ok
SYS/FANBD1/FM1/F0 TACH ok
SYS/FANBD1/FM1/F1 TACH ok
SYS/FANBD1/FM2/F0 TACH ok
SYS/FANBD1/FM2/F1 TACH ok
Fan indicators:
----------------------------------------------------------------
Location Sensor Condition
----------------------------------------------------------------
SYS/PS0 FAN_FAULT ok
SYS/PS1 FAN_FAULT ok
Temperature sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/MB T_AMB ok
SYS/MB/CMP0/BR0/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D0 T_AMB ok
SYS/MB/CMP0 T_TCORE ok
SYS/MB/CMP0 T_BCORE ok
Temperature indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/PS0 TEMP_FAULT ok
SYS/PS1 TEMP_FAULT ok
Current sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/PS0 I_IN_MAIN ok
SYS/PS0 I_IN_LIMIT ok
SYS/PS0 I_OUT_MAIN ok
SYS/PS0 I_OUT_LIMIT ok
SYS/PS1 I_IN_MAIN ok
SYS/PS1 I_IN_LIMIT ok
SYS/PS1 I_OUT_MAIN ok
SYS/PS1 I_OUT_LIMIT ok
Current indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/MB I_USB0 ok
SYS/MB I_USB1 ok
SYS/PS0 CUR_FAULT ok
SYS/PS1 CUR_FAULT ok
Voltage sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/MB V_VMEML ok
SYS/MB V_VMEMR ok
SYS/MB V_+3V3_STBY ok
SYS/MB V_VCORE ok
SYS/MB V_+3V3_MAIN ok
SYS/MB V_VDDIO ok
SYS/MB V_+12V0_MAIN ok
SYS/MB V_VBAT ok
SYS/PS0 V_IN_MAIN ok
SYS/PS0 V_OUT_MAIN ok
SYS/PS1 V_IN_MAIN ok
SYS/PS1 V_OUT_MAIN ok
Voltage indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/MB VCORE_POK ok
SYS/MB VMEML_POK ok
SYS/MB VMEMR_POK ok
SYS/PS0 AC_POK ok
SYS/PS0 DC_POK ok
SYS/PS0 VOLT_FAULT ok
SYS/PS1 AC_POK ok
SYS/PS1 DC_POK ok
SYS/PS1 VOLT_FAULT ok
LEDs:
----------------------------------------------------------------
Location LED State
----------------------------------------------------------------
SYS SERVICE off
SYS LOCATE off
SYS ACT steady
SYS PS_FAULT off
SYS TEMP_FAULT off
SYS FAN_FAULT off
SYS/MB/CMP0/BR0/CH0/D0 SERVICE off
SYS/MB/CMP0/BR0/CH1/D0 SERVICE off
SYS/MB/CMP0/BR1/CH0/D0 SERVICE off
SYS/MB/CMP0/BR1/CH1/D0 SERVICE off
SYS/MB/CMP0/BR2/CH0/D0 SERVICE off
SYS/MB/CMP0/BR2/CH1/D0 SERVICE off
SYS/MB/CMP0/BR3/CH0/D0 SERVICE off
SYS/MB/CMP0/BR3/CH1/D0 SERVICE off
SYS/HDD0 SERVICE off
SYS/HDD0 OK2RM off
SYS/HDD1 SERVICE off
SYS/HDD1 OK2RM off
SYS/HDD2 SERVICE off
SYS/HDD2 OK2RM off
SYS/HDD3 SERVICE off
SYS/HDD3 OK2RM off
SYS/HDD4 SERVICE off
SYS/HDD4 OK2RM off
SYS/HDD5 SERVICE off
SYS/HDD5 OK2RM off
SYS/HDD6 SERVICE off
SYS/HDD6 OK2RM off
SYS/HDD7 SERVICE off
SYS/HDD7 OK2RM off
SYS/FANBD0/FM0 SERVICE off
SYS/FANBD0/FM1 SERVICE off
SYS/FANBD0/FM2 SERVICE off
SYS/FANBD0/FM3 SERVICE off
SYS/FANBD1/FM0 SERVICE off
SYS/FANBD1/FM1 SERVICE off
SYS/FANBD1/FM2 SERVICE off
============================ FRU Status ============================
Location Name Status
------------------------------------------------------
SYS MB enabled
SYS/MB RISER0 enabled
SYS/MB RISER1 enabled
SYS/MB RISER2 enabled
SYS/MB SCC_NVRAM enabled
SYS/MB/CMP0/BR0/CH0 D0 enabled
SYS/MB/CMP0/BR0/CH1 D0 enabled
SYS/MB/CMP0/BR1/CH0 D0 enabled
SYS/MB/CMP0/BR1/CH1 D0 enabled
SYS/MB/CMP0/BR2/CH0 D0 enabled
SYS/MB/CMP0/BR2/CH1 D0 enabled
SYS/MB/CMP0/BR3/CH0 D0 enabled
SYS/MB/CMP0/BR3/CH1 D0 enabled
SYS HDD0 enabled
SYS HDD1 enabled
SYS HDD2 Not present
SYS HDD3 Not present
SYS HDD4 Not present
SYS HDD5 Not present
SYS HDD6 Not present
SYS HDD7 Not present
SYS PDB enabled
SYS PADCRD enabled
SYS SASBP enabled
SYS DVD enabled
SYS USBBD enabled
SYS FANBD0 enabled
SYS/FANBD0 FM0 enabled
SYS/FANBD0 FM1 enabled
SYS/FANBD0 FM2 enabled
SYS/FANBD0 FM3 enabled
SYS FANBD1 enabled
SYS/FANBD1 FM0 enabled
SYS/FANBD1 FM1 enabled
SYS/FANBD1 FM2 enabled
SYS PS0 enabled
SYS PS1 enabled
============================ FW Version ============================
Version
------------------------------------------------------------
Sun System Firmware 7.4.5 2012/12/11 23:47
====================== System PROM revisions =======================
Version
------------------------------------------------------------
OBP 4.33.6.b 2012/12/11 20:50
Chassis Serial Number
---------------------
XXXXXXXXXXXXXXXX
Hi,
I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1"
The System did come preinstalled as it comes from sun. I did not do much on it.
I booted system using boot cdrom -s
gave format... (6 Replies)
Hi,
I am using 3 t5120 sparc systems, OS solaris 10.
I am confused by update manager behaviour and sun support.
Sun support guy, tells me install patch : 136932-09 (#136932-09: Hardware/PROM: SPARC Enterprise T5120 & T5220 Sun System Firmware with LDOMS support)
When I checked... (4 Replies)
Hi,
I have problem creating hardware raid on T5120 with 4 disks. After the hardware raid 1 created, then I used the raidctl -l c1t0d0 and raidctl -l c1t2d0
the output of volume c1t0d0 contain disk 0.0.0 0.1.0, also the volume c1t2d0 contain disk 0.0.0 0.1.0 and should be 0.2.0 0.3.0
so I... (15 Replies)
Good Day,
We have bought Sun Sparc Enterprise T5120 with pre-installed Solaris 10 Sparc
But i need on this server Solaris 9. I have inserted in to DVD-rom (USB DVD-rom) with Solaris 9 for Sparc.
Then log into shell and type: reboot -- cdrom.
System rebooted and i have this message:
... (3 Replies)
hi all, i have a problem with a sun server, since a while the root password has been lost and now that we need to give maintenance to the services hosted in it, we cant access it, i tried a method to change it by booting from cd but i cant direct the server to boot from the cd. (The server is on... (3 Replies)
greetings.
im a very new user to solaris (and to servers for that matter) and i need to conect to a t5120 sun server, i tried using the SER-MGT port on the back of the server, then to a rj-45/db-9 adaptor, and to a serial-usb adaptor (my laptop doesn't have a com port).
when i try to conect with... (2 Replies)
Hi everyone
I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive.
My question is, how would I know when one of the drives become faulty?
Thanks (2 Replies)
I have a T5120 server and we found out on a security scan that the web interface for the ILOM is enabled. I have been trying to find this information in the wonderful documentation but have not been successful.
Does anyone know if you need the http/https enabled on the ILOM for the serial... (4 Replies)
I have 2machines, 1 T5120 and 1 T5240. Just wandering everytime we have powershutdown, I need to connect thru SP console to boot the T5120. The other machine T5240 is ok and can boot normally after I press the power button. On T5120, no matter how I press the power button, it just stays there,... (3 Replies)