Sponsored Content
Operating Systems Linux Red Hat Physical Volume Create Conundrum Post 302852463 by scotbuff on Wednesday 11th of September 2013 03:34:18 PM
Old 09-11-2013
Physical Volume Create Conundrum

I want to start by saying I already resolved my issue but I want to understand why I am seeing what I am seeing.

I have a server with a RAID controller two 500GB drives and six 600GB drives. The two 500GB drives are mirrored and have the OS installed on them. The six 600GB they wanted set as RAID0 and wanted them in a new volume group. My issue was getting the full size out of the RAID0 Virtual Disk.

On boot I saw the disk:
sd 0:2:1:0: [sdb] 7025983488 512-byte logical blocks: (3.59 TB/3.27 TiB)

I work mostly with LUNs and generally I can just do a pvcreate and I am ready to use the disk. But I could not issue a pvcreate on /dev/sdb and it seemed to need to be partitioned. So I used fdisk using this procedure, which I found to be the same on Red Hat's website:
Create Linux Partition

Once I had a partition I was issuing a pvcreate /dev/sdb1 and each time I ended up with only 2TB of usable space.
Code:
[root@testserv dev]# pvcreate /dev/sdb1
  Physical volume "/dev/sdb1" successfully created
[root@testserv dev]# pvscan
  PV /dev/sda2   VG vg01            lvm2 [464.75 GiB / 355.75 GiB free]
  PV /dev/sdb1                      lvm2 [2.00 TiB]

I ended up just issuing a pvremove, removing the partition and issueing a vgcreate against the raw device. I noticed that the vgcreate created the physical volume for me and it was the correct size.
Code:
[root@testserv ~]# vgcreate scratchvg /dev/sdb
  No physical volume label read from /dev/sdb
  Physical volume "/dev/sdb" successfully created
  Volume group "scratchvg" successfully created
[root@testserv ~]# pvscan
  PV /dev/sdb    VG scratchvg   lvm2 [3.27 TiB / 3.27 TiB free]
  PV /dev/sda2   VG vg01        lvm2 [464.75 GiB / 355.75 GiB free]
  Total: 2 [3.73 TiB] / in use: 2 [3.73 TiB] / in no VG: 0 [0   ]

My question is, what am I missing? I am completely fine with just skipping the fdisk and pvcreate steps but I thought I had to do those steps. What was I doing wrong? What is the proper procedure when taking a Virtual Disk presented by a RAID controller and creating or adding it to a volume group? I guess my own answer would be the procedure that works, but since I found so many references to using fdisk and partitioning the disk I am curious why that was not working for me. Thanks.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

physical volume and physical disk.

Hello, I need explanations about physical disks and physical volumes. What is the difference between these 2 things? In fact, i am trying to understand what the AIX lspv2command does. Thank you in advance. (2 Replies)
Discussion started by: VeroL
2 Replies

2. UNIX for Dummies Questions & Answers

Physical volume- no free physical partitions

I was in smit, checking on disc space, etc. and it appears that one of our physical volumes that is part of a large volume group, has no free physical partitions. The server is running AIX 5.1. What would be the advisable step to take in this instance? (9 Replies)
Discussion started by: markper
9 Replies

3. AIX

Basic Filesystem / Physical Volume / Logical Volume Check

Hi! Can anyone help me on how I can do a basic check on the Unix filesystems / physical volumes and logical volumes? What items should I check, like where do I look at in smit? Or are there commands that I should execute? I need to do this as I was informed by IBM that there seems to be... (1 Reply)
Discussion started by: chipahoys
1 Replies

4. UNIX for Dummies Questions & Answers

trying to devide existing physical volume

hi guys, i`m trying to take 40GB of my sda5 (/home mounted) to create new volume group(lvc) here`s the df output: /dev/sda2 7,9G 3,3G 4,3G 44% / udevfs 5,0M 60K 5,0M 2% /dev shmfs 379M 0 379M 0% /dev/shm tmpfs 379M ... (2 Replies)
Discussion started by: neverhood
2 Replies

5. AIX

How to determine the physical volume fo the disks

This is the report I got running the comand rptconf, but I would like to know what is the capacity of the disks installed into our server power 6 with AIX System Model: IBM,7778-23X Machine Serial Number: 1066D5A Processor Type: PowerPC_POWER6 Processor Implementation Mode: POWER 6... (6 Replies)
Discussion started by: cucosss
6 Replies

6. UNIX for Dummies Questions & Answers

importing a Physical Volume

hi guys I'm added a new disk to my server (virtual environment) It used to be a Volume Group=Vol_Group01 and Logical Volume= Log_Vol_01_Data and I see /dev/sdb Disk /dev/sdb doesn't contain a valid partition table Disk /dev/sdc: 133.1 GB, 133143986176 bytes 255 heads, 63... (3 Replies)
Discussion started by: karlochacon
3 Replies

7. UNIX for Dummies Questions & Answers

Confusion Regarding Physical Volume,Volume Group,Logical Volume,Physical partition

Hi, I am new to unix. I am working on Red Hat Linux and side by side on AIX also. After reading the concepts of Storage, I am now really confused regarding the terminologies 1)Physical Volume 2)Volume Group 3)Logical Volume 4)Physical Partition Please help me to understand these concepts. (6 Replies)
Discussion started by: kashifsd17
6 Replies

8. Red Hat

Create volume using LVM over 2 physical disks

I wanted to know how we can combine volumes over 2 physical drives. # fdisk -l Disk /dev/sda: 42.9 GB, 42949672960 bytes 255 heads, 63 sectors/track, 5221 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sda1 ... (16 Replies)
Discussion started by: ikn3
16 Replies

9. AIX

Position of the logical volume on the physical volume

Hello everyone, I just read that while creating a logical volume(LV) we can choose the region of the physical volume (PV) in which the LV should be created. When I say region I mean: outer edge - outer middle - center - inner middle and inner edge. Can anyone help me understand the utility... (11 Replies)
Discussion started by: adilyos
11 Replies

10. Red Hat

No space in volume group. How to create a file system using existing logical volume

Hello Guys, I want to create a file system dedicated for an application installation. But there is no space in volume group to create a new logical volume. There is enough space in other logical volume which is being mounted on /var. I know we can use that logical volume and create a virtual... (2 Replies)
Discussion started by: vamshigvk475
2 Replies
CCISS_VOL_STATUS(8)													       CCISS_VOL_STATUS(8)

NAME
cciss_vol_status - show status of logical drives attached to HP Smartarray controllers SYNOPSIS
cciss_vol_status [OPTION] [DEVICE]... DESCRIPTION
Shows the status of logical drives configured on HP Smartarray controllers. OPTIONS
-p, --persnickety Without this option, device nodes which can't be opened, or which are not found to be of the correct device type are silently ignored. This lets you use wildcards, e.g.: cciss_vol_status /dev/sg* /dev/cciss/c*d0, and the program will not complain as long as all devices which are found to be of the correct type are found to be ok. However, you may wish to explicitly list the devices you expect to be there, and be notified if they are not there (e.g. perhaps a PCI slot has died, and the system has rebooted, so that what was once /dev/cciss/c1d0 is no longer there at all). This option will cause the program to complain about any device node listed which does not appear to be the right device type, or is not openable. -C, --copyright If stderr is a terminal, Print out a copyright message, and exit. -q, --quiet This option doesn't do anything. Previously, without this option and if stderr is a terminal, a copyright message precedes the nor- mal program output. Now, the copyright message is only printed via the -C option. -s Query each physical drive for S.M.A.R.T data and report any drives in "predictive failure" state. -u, --try-unknown-devices If a device has an unrecognized board ID, normally the program will not attempt to communicate with it. In case you have some Smart Array controller which is newer than this program, the program may not recognize it. This option permits the program to attempt to interrogate the board even if it is unrecognized on the assumption that it is in fact a Smart Array of some kind. -v, --version Print the version number and exit. -x, --exhaustive Deprecated. Previously, it "exhaustively" searched for logical drives, as, under some circumstances some logical drives might oth- erwise be missed. This option no longer does anything, as the algorithm for finding logical drives was changed to obviate the need for it. DEVICE
The DEVICE argument indicates which RAID controller is to be queried. Note, that it indicates which RAID controller, not which logical drive. For the cciss driver, the "d0" nodes matching "/dev/cciss/c*d0" are the nodes which correspond to the RAID controllers. (See note 1, below.) It is not necessary to invoke cciss_vol_status on each logical drive individually, though if you do this, each time it will report the status of ALL logical drives on the controller. For the hpsa driver, or for fibre attached MSA1000 family devices, or for the hpahcisr sotware RAID driver which emulates Smart Arrays, the RAID controller is accessed via the scsi generic driver, and the device nodes will match "/dev/sg*" Some variants of the "lsscsi" tool will easily identify which device node corresponds to the RAID controller. Some variants may only report the SCSI nexus (con- troller/bus/target/lun tuple.) Some distros may not have the lsscsi tool. Executing the following query to the /sys filesystem and correlating this with the contents of /proc/scsi/scsi or output of lsscsi can help in finding the right /dev/sg node to use with cciss_vol_status: wumpus:/home/scameron # ls -l /sys/class/scsi_generic/* lrwxrwxrwx 1 root root 0 2009-11-18 12:31 /sys/class/scsi_generic/sg0 -> ../../devices/pci0000:00/0000:00:02.0/0000:02:00.0/0000:03:03.0/host0/target0:0:0/0:0:0:0/scsi_generic/sg0 lrwxrwxrwx 1 root root 0 2009-11-18 12:31 /sys/class/scsi_generic/sg1 -> ../../devices/pci0000:00/0000:00:1f.1/host2/target2:0:0/2:0:0:0/scsi_generic/sg1 lrwxrwxrwx 1 root root 0 2009-11-19 07:47 /sys/class/scsi_generic/sg2 -> ../../devices/pci0000:00/0000:00:05.0/0000:0e:00.0/host4/target4:3:0/4:3:0:0/scsi_generic/sg2 wumpus:/home/scameron # cat /proc/scsi/scsi Attached devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: COMPAQ Model: BD03685A24 Rev: HPB6 Type: Direct-Access ANSI SCSI revision: 03 Host: scsi2 Channel: 00 Id: 00 Lun: 00 Vendor: SAMSUNG Model: CD-ROM SC-148A Rev: B408 Type: CD-ROM ANSI SCSI revision: 05 Host: scsi4 Channel: 03 Id: 00 Lun: 00 Vendor: HP Model: P800 Rev: 6.82 Type: RAID ANSI SCSI revision: 00 wumpus:/home/scameron # lsscsi [0:0:0:0] disk COMPAQ BD03685A24 HPB6 /dev/sda [2:0:0:0] cd/dvd SAMSUNG CD-ROM SC-148A B408 /dev/sr0 [4:3:0:0] storage HP P800 6.82 - From the above you can see that /dev/sg2 corresponds to SCSI nexus 4:3:0:0, which corresponds to the HP P800 RAID controller listed in /proc/scsi/scsi. EXAMPLE
[root@somehost]# cciss_vol_status -q /dev/cciss/c*d0 /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK. /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 1 status: OK. /dev/cciss/c0d0: (Smart Array P800) RAID 1 Volume 2 status: OK. /dev/cciss/c0d0: (Smart Array P800) RAID 5 Volume 4 status: OK. /dev/cciss/c0d0: (Smart Array P800) RAID 5 Volume 5 status: OK. /dev/cciss/c0d0: (Smart Array P800) Enclosure MSA60 (S/N: USP6340B3F) on Bus 2, Physical Port 1E status: Power Supply Unit failed /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 0 status: OK. /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 1 status: OK. /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 2 status: OK. /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 3 status: OK. /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 4 status: OK. /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 5 status: OK. /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 6 status: OK. /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 7 status: OK. [root@someotherhost]# cciss_vol_status -q /dev/sg0 /dev/cciss/c*d0 /dev/sg0: (MSA1000) RAID 1 Volume 0 status: OK. At least one spare drive. /dev/sg0: (MSA1000) RAID 5 Volume 1 status: OK. /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK. [root@localhost]# ./cciss_vol_status -s /dev/sg1 /dev/sda: (Smart Array P410i) RAID 0 Volume 0 status: OK. connector 1I box 1 bay 1 HP DG072A9BB7 B365P6803PCP0633 HPD0 S.M.A.R.T. predictive failure. [root@localhost]# echo $? 1 [root@localhost]# ./cciss_vol_status -s /dev/cciss/c0d0 /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK. connector 2E box 1 bay 8 HP DF300BB6C3 3LM08AP700009713RXUT HPD3 S.M.A.R.T. predictive failure. /dev/cciss/c0d0: (Smart Array P800) Enclosure MSA60 (S/N: USP6340B3F) on Bus 2, Physical Port 2E status: OK. DIAGNOSTICS
Normally, a logical drive in good working order should report a status of "OK." Possible status values are: "OK." (0) - The logical drive is in good working order. "FAILED." (1) - The logical drive has failed, and no i/o to it is poosible. Additionally, failed drives will be identified by connector, box and bay, as well as vendor, model, serial number, and firmware revision. "Using interim recovery mode." (3) - One or more drives has failed, but not so many that the logical drive can no longer operate. The failed drives should be replaced as soon as possible. "Ready for recovery operation." (4) - Failed drive(s) have been replaced, and the controller is about to begin rebuilding redundant parity data. "Currently recovering." (5) - Failed drive(s) have been replaced, and the controller is currently rebuilding redundant parity information. "Wrong physical drive was replaced." (6) - A drive has failed, and another (working) drive was replaced. "A physical drive is not properly connected." (7) - There is some cabling or backplane problem in the drive enclosure. (From fwspecwww.doc, see cpqarray project on sourceforge.net): Note: If the unit_status value is 6 (Wrong physical drive was replaced) or 7 (A physical drive is not properly connected), the unit_status of all other configured logical drives will be marked as 1 (Logical drive failed). This is to force the user to correct the problem and to insure that once the problem is corrected, the data will not have been corrupted by any user action. "Hardware is overheating." (8) - Hardware is too hot. "Hardware was overheated." (9) - At some point in the past, the hardware got too hot. "Currently expannding." (10) - The controller is currently in the process of expanding a logical drive. "Not yet available." (11) - The logical drive is not yet finished being configured. "Queued for expansion." (12) - The logical drive will be expended when the controller is able to begin working on it. Additionally, the following messages may appear regarding spare drive status: "At least one spare drive designated" "At least one spare drive activated and currently rebuilding" "At least one activated on-line spare drive is completely rebuilt on this logical drive" "At least one spare drive has failed" "At least one spare drive activated" "At least one spare drive remains available" Active spares will be identified by connector, box and bay, as well as by vendor, model, serial number, and firmware revision. For each logical drive, the total number of failed physical drives, if more than zero, will be reported as: "Total of n failed physical drives detected on this logical drive." with "n" replaced by the actual number, of course. "Replacement" drives -- newly inserted drives that replace a previously failed drive but are not yet finished rebuilding -- are also iden- tified by connector, box and bay, as well as by vendor, model, serial number, and firmware revision. If the -s option is specified, each physical drive will be queried for S.M.A.R.T data, any any drives in predictive failure state will be reported, identified by connector, box and bay, as well as vendor, model, serial number, and firmware revision. Additionally failure conditions of disk enclosure fans, power supplies, and temperature are reported as follows: "Fan failed" "Temperature problem" "Door alert" "Power Supply Unit failed" FILES
/dev/cciss/c*d0 (Smart Array PCI controllers using the cciss driver) /dev/sg* (Fibre attached MSA1000 controllers and Smart Array controllers using the hpsa driver or hpahcisr software RAID driver.) EXIT CODES
0 - All configured logical drives queried have status of "OK." 1 - One or more configured logical drives queried have status other than "OK." AUTHOR
Written by Stephen M. Cameron REPORTING BUGS
MSA500 G1 logical drive numbers may not be reported correctly. I've seen enclosure serial numbers contain garbage. Report bugs to <steve.cameron@hp.com> COPYRIGHT
Copyright (C) 2007 Hewlett-Packard Development Company, L.P. This is free software; see the source for copying conditions. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICU- LAR PURPOSE. SEE ALSO
http://cciss.sourceforge.net NOTE 1 The /dev/cciss/c*d0 device nodes of the cciss driver do double duty. They serve as an access point to both the RAID controllers, and to the first logical drive of each RAID controller. Notice that a /dev/cciss/c*d0 node will be present for each controller even if no logical drives are configured on that controller. It might be cleaner if the driver had a special device node just for the controller, instead of making these device nodes do double duty. It has been like that since the 2.2 linux kernel timeframe. At that time, device major and minor nodes were statically allocated at compile time, and were in short supply. Changing this behavior at this point would break lots of userland programs. cciss_vol_status (ccissutils) Nov 2009 CCISS_VOL_STATUS(8)