Sponsored Content
Operating Systems AIX SAN Disk Appearing double in AIX Post 302846373 by filosophizer on Friday 23rd of August 2013 03:42:23 PM
Old 08-23-2013
Thanks for the replies, IBMTECH and Dukessd

My company has an old system P4 with the following config

Code:
# prtconf | more
System Model: IBM,7029-6C3
Processor Type: PowerPC_POWER4
Number Of Processors: 2
Processor Clock Speed: 1200 MHz
CPU Type: 64-bit
Kernel Type: 32-bit
LPAR Info: 1 NULL
Memory Size: 16384 MB
Good Memory Size: 16384 MB
Firmware Version: IBM,RG040325_d75e04_s
Console Login: enable
Auto Restart: true
Full Core: false

# lsdev -Cc adapter

fcs0      Available 1H-08    FC Adapter
fcs1      Available 1n-08    FC Adapter

lscfg -vl fcs0
  fcs0             U0.1-P1-I5/Q1  FC Adapter

        Part Number.................00P4295
        EC Level....................A
        Serial Number...............1D4230CADC
        Manufacturer................001D
        Feature Code/Marketing ID...5704
        FRU Number..................     00P4297
        Device Specific.(ZM)........3
        Network Address.............10000000C93E6B3E
        ROS Level and ID............02E01871
        Device Specific.(Z0)........2003806D
        Device Specific.(Z1)........00000000
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........03000909
        Device Specific.(Z4)........FF601231
        Device Specific.(Z5)........02E01871
        Device Specific.(Z6)........06631871
        Device Specific.(Z7)........07631871
        Device Specific.(Z8)........20000000C93E6B3E
        Device Specific.(Z9)........HS1.81X1
        Device Specific.(ZA)........H1D1.81X1
        Device Specific.(ZB)........H2D1.81X1
        Device Specific.(YL)........U0.1-P1-I5/Q1


# oslevel -r

5200-05

which AIX 5.2 ML 05

# lsdev -Cc disk
hdisk0 Available 1S-08-00-5,0 16 Bit LVD SCSI Disk Drive
hdisk1 Available 1S-08-00-8,0 16 Bit LVD SCSI Disk Drive
hdisk2 Available 1n-08-02     1722-600 (600) Disk Array Device
hdisk3 Available 1H-08-02     1722-600 (600) Disk Array Device
hdisk4 Available 1n-08-02     1722-600 (600) Disk Array Device
hdisk5 Available 1H-08-02     1722-600 (600) Disk Array Device
hdisk6 Available 1n-08-02     1722-600 (600) Disk Array Device

lspath -H
status  name   parent

Enabled hdisk0 scsi0
Enabled hdisk1 scsi0

lslpp -l | grep mpio
  devices.common.IBM.mpio.rte

lslpp -lc | grep mpio
/usr/lib/objrepos:devices.common.IBM.mpio.rte:5.2.0.50::COMMITTED:F:MPIO Disk Path Control Module:

manage_disk_drivers -l
ksh: manage_disk_drivers:  not found.

///not found due to old version 5.2

mpio_get_config -Av
ksh: mpio_get_config:  not found.

///not found due to old version 5.2


SAN STORAGE DS4300 
PROFILE FOR STORAGE SUBSYSTEM:  (8/23/13 10:43:42 PM)

SUMMARY------------------------------
   Number of controllers: 2
   Number of arrays: 4
   Total number of logical drives (includes an access logical drive): 6 of 1024 used
      Number of standard logical drives: 5
      Number of access logical drives: 1
   Number of drives: 14
   Supported drive types: Fibre (14)
   Total hot spare drives: 4
      Standby: 4
      In use: 0
   Access logical drive: LUN 31 (see Mappings section for details)
   Default host type: AIX (Host type index 6)
   Current configuration
      Firmware version: 06.12.16.00
      NVSRAM version: N1722F600R912V05
   Pending configuration
      Staged firmware download supported?: Yes
      Firmware version: None
      NVSRAM version: None
      Transferred on: None

But this one doesn't have any issues, Controller A is connected to Port 0 of Fiber Card 1 and Controller B is connected to Port 1 of Fiber Card 2 but there is a switch in between them and there is zoning.


I will zone the switch as IBMTECH suggested and try and post the details...

If anyone know how to solve this issue, please post.
thanks
 

10 More Discussions You Might Find Interesting

1. AIX

AIX disk less with SAN

Hi All, I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX? Is that going to boot on SAN rootvg volume? Thanks in advance, itik (3 Replies)
Discussion started by: itik
3 Replies

2. AIX

hard disk and san

Hello everyone I got several aix boxes with aix 5.3 I got a ibm san ds4500 My question is How can I do a match between my disks on aix and the san? I try to do a match with the LUN but for example. In my san I got several 1 LUN and on one of my aix box I got this If I type lscfg... (4 Replies)
Discussion started by: lo-lp-kl
4 Replies

3. AIX

AIX 5.2/5.3 - rootvg on SAN disk - pros and cons

We are considering a DR strategy of booting AIX 5.3 and 5.3 logical partitions from EMC Symmetrix SAN disks, so that we can replicate via SRDF to a recovery site. Has anyone tried configuring AIX 5.x systems to boot from SAN disk? If so, can you provide any information on the pros and cons of... (6 Replies)
Discussion started by: jjgarrot
6 Replies

4. Solaris

SAN disk failure

hi all, have a solaris 9 OS and a SAN disk which used to work fine is not getting picked up by my machine. can anyone point out things to check in order to troubleshoot this ?? thanks in advance. (3 Replies)
Discussion started by: cesarNZ
3 Replies

5. Filesystems, Disks and Memory

SAN Disk w/o Cluster

Scenario: I've got 2 M5000's connected to a 9985 SAN storage array. I have configured the SAN disks with stmsboot, format and newfs. I can access the same SAN space from both systems. I have created files from both systems on the SAN space. Question: Why can't I see the file created... (3 Replies)
Discussion started by: bluescreen
3 Replies

6. UNIX for Dummies Questions & Answers

SAN and Disk I/O ... do we care?

Hi all, My main function is as a DBA. Another person manages the server and the SAN. I just want to know if I should be worried about high disk I/O or is it irrelevant as the I/O "load balancing" will be "taken care" of by the SAN? For example, I have hdisk1-5 and I can see that there are... (2 Replies)
Discussion started by: newbie_01
2 Replies

7. Solaris

I/O Error on SAN Disk

Hi, I have a production solaris 10 SPARC system (portal). Yesterday legato/Networker gave an I/O Error on one of the files on its SAN mounted disk. I went to that particular file on the system, did an ls and it showed the file. However, ls -l did not work and it said IO error. ... (6 Replies)
Discussion started by: Mack1982
6 Replies

8. AIX

SAN DISK raid level in AIX

Hello All, Our servers having emc clarion for the data disks. Is that possible to see those san disks raid level from AIX ? Am having AIX 6.1 and EMC clarion 5.5. Regards, Gowtham.G (3 Replies)
Discussion started by: gowthamakanthan
3 Replies

9. AIX

San disk appearing double in old AIX

Hi guys, :) I'm a studient in IT field (AIX) I'm trying to map a LUN from a SAN (DS3400) to an AIX server (5300-04-00) I know there is no MPIO on this version of AIX, and i see double my LUN from the SAN root@localhost # lscfg | grep hdisk + hdisk7 ... (13 Replies)
Discussion started by: Tharsan
13 Replies

10. UNIX for Beginners Questions & Answers

SAN vs. Local disk.

I am in the market looking to purchase a new E950 server and I am trying to decide between using local SSD drives or SSD based SAN. The application that will be running on this server is read-intensive so I am looking for the most optimal configuration to support this application. There are no... (2 Replies)
Discussion started by: ikx
2 Replies
fp(7d)								      Devices								    fp(7d)

NAME
fp - Sun Fibre Channel port driver DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter port management and other capabilities through well-defined fibre channel adapter driver interfaces. The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri- vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in LIRP and LILP stages of loop initialization. CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties: mpxio-disable Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no" activates I/O multipathing, while mpxio-disable="yes" disables the feature. Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4: name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0 mpxio-disable="yes"; manual_configuration_only Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con- figuration of devices. FILES
/kernel/drv/fp 32-bit ELF kernel driver (x86) /kernel/drv/amd64/fp 64-bit ELF kernel driver (x86) /kernel/drv/sparcv9/fp 64-bit ELF kernel driver (SPARC) /kernel/drv/fp.conf fp driver configuration file. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |mpxio-disable |Unstable | +-----------------------------+-----------------------------+ |manual_configuration_only |Obsolete | +-----------------------------+-----------------------------+ |Availability |SUNWfctl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D) Writing Device Drivers Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994 Fibre Channel Generic Services (FC-GS-2) Project 1134-D Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996 Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996 SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998 Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998 SunOS 5.10 2 Dec 2004 fp(7d)
All times are GMT -4. The time now is 04:11 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy